Introduction
Single-pass tangential flow filtration (SPTFF) is revolutionizing how TFF is implemented in biotech, vaccine, blood plasma, and other applications. Cadence™ inline concentrator (ILC) modules allow direct flowthrough volume reduction and can be implemented into a process system or operated as a stand-alone unit. This exciting technology leads to economic and practical benefits, including:
- Ability to couple the concentration of product before or after other downstream processing (DSP) steps, consequently optimizing other steps and reducing in-process pool tank volumes.
- Continuous processing in DSP.
- Easy integration of the assembled module, allowing plug-and-play operation.
- Potential reduction of product damage or aggregation due to reduced residence time and shear exposure.
These modules are offered with either Delta regenerated cellulose or Omega™ polyethersulfone membranes providing the high flux, high selectivity, and low protein binding characteristics that are associated with these membranes. Table 1 shows the detail of the available Cadence ILC module formats.
Table 1.Available formats of the Cadence inline concentrator modules with Delta and Omega membranes
| Membrane and MWCO1 | Cassette format | Membrane area (m2) | Product code |
| Delta 10 kDa | T01 | 0.065 | ILD010T010407 |
| T02 | 0.13 | ILD010T020407 | |
| T12 | 0.7 | ILD010T120407 | |
| T06 | 3.5 | ILD010T060407 | |
| Delta 30 kDa | T01 | 0.065 | ILD030T010407 |
| T02 | 0.13 | ILD030T020407 | |
| T12 | 0.7 | ILD030T120407 | |
| T06 | 3.5 | ILD030T060407 | |
| Omega 10 kDa | T01 | 0.065 | ILOS010T010407 |
| T02 | 0.13 | ILOS010T020407 | |
| T12 | 0.7 | ILOS010T120407 | |
| T06 | 3.5 | ILOS010T060407 | |
| Omega 30 kDa | T01 | 0.065 | ILOS030T010407 |
| T02 | 0.13 | ILOS030T020407 | |
| T12 | 0.7 | ILOS030T120407 | |
| T06 | 3.5 | ILOS030T060407 |
1 Molecular weight cut-off in kilodaltons (kDa).
Operational feed pressure, concentration factor, and the recovery of the normalized water permeability (NWP) are the primary determinants for demonstrating the ability to reuse the module, as they define processing times and the required membrane area. It is important that these values be consistent so that the end user will be able to confidently reuse the Cadence ILC modules with minimal expected change in performance. Large performance differences between runs could negatively impact the final process by extending the processing time due to a maximum operational pressure being reached and the requirement of more frequent cleaning cycles. Thus, the focus of this study was to demonstrate process repeatability and cleanability of the Cadence ILC module with Omega membranes for limited reuse applications.
Materials and methods
A schematic of the laboratory equipment used for this study is shown in Figure 1.
Fig 1. Laboratory equipment setup.
We selected the Cadence ILC module with T01 Centramate cassettes with Omega 30 kDa membrane (ILOS030T010407) for this study. Five 24 h protein concentration cycles were conducted in total recirculation mode (with the retentate and permeate lines directed back to the feed reservoir) at room temperature. A schematic of the laboratory equipment used for this study is shown in Figure 1. Both permeate ports were open during the tests. A pressure sensor was installed before the Cadence ILC module feed port to monitor the feed pressure.
The Cadence ILC module was preconditioned and characterized for NWP before each 24 h cycle. A 2 L solution of 10 g/L human immunoglobulin (IgG) in a 10 mM histidine, 100 mM sodium chloride, pH 6.0 buffer was chosen as feed solution. In each test, the pump speed was adjusted to achieve an initial feed pressure of 1.7 barg (25 psig). The system was then run in recirculation mode for 24 h. The feed pressure, feed flow rate, and retentate flow rate were recorded periodically. Flow rates and feed pressure data were used to calculate the volumetric concentration factor (VCF [VCF = the feed flow rate divided by the retentate flow rate]) and membrane permeability.
After the processing with protein, the Cadence ILC module was flushed with a 20 L/m2 single-pass flush with water at a feed pressure of 2.8 barg (40 psig) with the retentate and permeate ports open and directed to drain. The precleaning NWP was measured and the Cadence ILC module was cleaned with the retentate and permeate ports open and the lines directed back to the feed vessel. A fresh aliquot (30 L/m2) of the cleaning solution (0.5 N sodium hydroxide with 400 ppm sodium hypochlorite) was recirculated through the module at a feed pressure of 2.8 barg (40 psig) for 2 h. Following the cleaning procedures, the Cadence ILC module was flushed with water, recharacterized for NWP, and stored in 0.1 N sodium hydroxide under ambient conditions.
Results and discussion
Figure 2 shows the VCF as a function of run time for the five concentration cycles with the 10 g/L human IgG solution. The VCF gradually decreased during each 24 h protein concentration process. The initial VCF was 5 ± 0.2-fold, which decreased to 3.9 ± 0.2-fold after 24 h for each of the five protein concentration runs.
Fig 2. VCF as a function of time for the Cadence ILC module with Omega 30 kDa membrane during the 24 h, 10 g/L human IgG concentration tests.
The NWP values (before each run, before cleaning post-use, and after cleaning) and the NWP recoveries for the Cadence ILC module with Omega 30 kDa membrane are displayed in Figure 3 and 4, respectively.
Fig 3. NWP values for the Cadence ILC module with Omega 30 kDa membrane processed with 10 g/L human IgG solution (before each run, before cleaning post-use, and after cleaning).
Fig 4. NWP recoveries for the Cadence ILC module with Omega 30 kDa membrane processed with 10 g/L human IgG solution (normalized to cycle 1 NWP in percentage).
Following each 24 h protein processing run with the Cadence ILC module with Omega 30 kDa membrane, the NWP of the Cadence ILC module decreased to 44% to 50% of the initial value prior to the run. The cleaning procedures using 0.5 N sodium hydroxide with 400 ppm sodium hypochlorite restored the NWP to ≥ 95% of its original NWP from Cycle 1. It should be noted that conventional TFF cassettes can be reused until the pre-use NWP decreases to 70% to 80% of its original value.
Conclusions
Based on the findings of this study, the Cadence inline concentrator module with Omega 30 kDa membrane could be reused several times with an acceptable change in performance. The process performance with respect to VCF did experience a gradual decrease in VCF from ~ 5-fold to ~ 3.9-fold over the 24 h protein concentration run. It is recommended that targeted end-user studies be conducted to determine an acceptable VCF range, to identify the limited reuse range, and to validate specific reuse requirements for each application.
CY62078