Shop in your local currency and language

Choose another country or region to see specific content for your location and shop online.

United Kingdom
Downstream bioprocessing

Lentivirus clarification from adherent cell culture

Sep 23, 2026

Filtration strategies for clarifying high-turbidity lentiviral harvests from adherent cell culture were evaluated. Cellulose-based depth filters significantly increased downstream membrane filter capacity while maintaining lentiviral recovery. Seitz™ V100P or PDK11 cellulose-based depth filters used as prefilters combined with a Supor™ EKV or EAV sterilizing-grade membrane provided a robust and scalable clarification solution for clarification of recombinant lentivirus from adherent cell cultures.

Introduction

In recent years, development in the cell and gene therapy industries has grown rapidly. One of the largest classes of viral vectors in development today is lentivirus (LV). Lentiviral vectors are enveloped and are roughly 120 nm in diameter. They deliver an RNA payload and are used in both gene therapy as well as many chimeric antigen receptor (CAR) T-based cell therapies.

Recombinant LV is produced in host cells which are often grown on substrates in adherent bioreactors. It is largely secreted from the cells, which means the vectors can be harvested from an adherent bioreactor without lysing or detaching the cells from the substrate. However, some cellular debris and particles do make it into the crude harvest, creating the need for a clarification step at the start of downstream purification.

Previous work (1) demonstrated strong clarification solutions for adherent LV cultures using various combinations of glass-fiber prefilters and polyethersulfone (PES) or polyvinylidene fluoride (PVDF) membrane filters. Using crude harvest pools with turbidities of approximately 10 NTU, these synthetic filter options provided capacities of > 1500 L/m2 and infectious particle recoveries of > 75%. Here we expand upon that work by screening prefilter and membrane filter options using higher turbidity feedstreams.

We evaluate performance and discuss selection criteria for synthetic vs cellulose-based prefilters, as well as sterilizing-grade vs bioburden reduction membrane filters.

Materials and methods

Crude harvest supply

All the LV pools used in this study were produced by transfection of adherent HEK293T cells grown in CellSTACK culture chambers or iCELLis™ Nano bioreactors. The iCELLis Nano bioreactor system is an automated, single-use, fixed-bed bioreactor for adherent cell culture.

The lentivirus produced was HIV-1 derived with a VSV-G pseudotype carrying a green fluorescent protein (GFP) gene insert. Supernatants were collected from the bioreactor 48 to 72 h after transfection and treated with 25 units/mL of Benzonase for 1 h at 37°C. These crude harvest pools had turbidities ranging from 20 to 73 NTU and an average concentration of 7.1 × 107 infectious particles/mL (IP/mL).

Clarification

All filtration work described here was run at constant flux on PendoTECH NFF control systems with peristaltic pumps on the feed lines. Pressures and filtrate volumes were recorded over time. Prefilters used in this work are shown in Table 1 and include sheets from our Seitz P-series depth filters and PreFlow™ series filters.

P-series filter sheets are made up of a combination of cellulose, inorganic filter aids, and a binding resin. The V100P is a sheet designed specifically for virus work that is low-charge and free of diatomaceous earth. In this work, the V100P and PDK11 filters were tested in Supracap™ 50 capsule format. PreFlow UB media is resin-bonded glass fiber and provides a gamma-stable option for protecting sterilizing-grade filters in bioprocessing. In this work, 47 mm discs were tested using stainless steel holders. Supor™ EKV sterilizing grade filters and Supor EAV bioburden reduction filters in Mini Kleenpak™ syringe format were used following prefiltration. More information on these filters can be found in Table 2.

Prefilters were flushed pre-use using 50 L/m2 of a 1× phosphate-buffered saline (PBS) solution, pH 7.4, at 300 L/m2/h (LMH) to ensure full wetting of the pores. The capsules and stainless-steel holder were first filled by allowing air in the void volume to escape through the vent. After flushing, the filter devices were drained by opening the vent and pouring the excess liquid out.

Experiments used to determine filter capacity were run in Pmax format to a terminal pressure of 0.7 bar (10 psi, 0.07 MPa). Adherent LV clarification capacity trials were run at 200 LMH on the prefilters and 500 LMH on the membrane filters. The prefilters were first filled with crude harvest and vented as described above. During filtration, pressure and turbidity data were collected as a function of time, and the filtration was stopped when a differential pressure of 0.7 bar was reached or turbidity breakthrough was observed. At the end of the LV filtration, the filters were flushed with 1.5× hold up volumes of 1× PBS solution. This flush was pooled with the LV filtrate and the virus titer was determined on the combined pool sample.

Analytics

Pool turbidities were measured offline on a Hach 2100Q portable turbidimeter. Pool titers were quantitated using a flow-cytometry based transduction unit (TU) assay. Step yields were calculated using the equation below where Vf and Vp refer to feed and filtrate pool volumes and Cf and Cp refer to feed and filtrate pool concentrations respectively.

Yield % = (Vp × Cp) (Vf × Cf) × 100

Table1. Description of prefilters used in this work

Filter Material description Retention rating Available capsule formats Effective filter area (EFA) Sterilization
PreFlow UB media Resin-bonded glass fiber 0.45 µm PreFlow capsules 0.09 m2 3 × 1 h cycles at 125°C
Kleenpak Nova capsules 0.68–2.0 m2 3 × 1 h cycles at 125°C or 50 kGy gamma-irradiated
Seitz V100P media Single layer made of cellulose fibers, perlite and resin 2–4 µm Supracap 50 capsules 22 cm2 1 × 30 min cycle at 125°C
Supracap 100 capsules 0.05–0.3 m2 1 × 1 h cycle at 125°C
Stax capsules 0.5–2.0 m2 2 × 1 h cycles at 125°C
Seitz PDK11 media
(dual-layer)
Dual layer made of cellulose fibers, filter aids, and resin 8–20 /
2–4 µm
Supracap 50 capsules 22 cm2 1 × 30 min cycle at 125°C
Supracap 100 capsules 0.025–0.15 m2 1 × 1 h cycle at 125°C
Stax capsules 0.25–1.0 m2 2 × 1 h cycles at 125°C

Table 2. Description of membrane filters used in this work

Filter Material description Retention rating Available capsule formats Effective filter area (EFA)
Supor EKV media Dual-layer PES 0.2 µm sterilizing grade Mini Kleenpak syringe filter 2.8 cm2
Mini Kleenpak 20 capsules 20 cm2
Mini Kleenpak capsules 200 cm2
Kleenpak capsules 375–1500 cm2
Kleenpak Nova capsules 0.26–1.8 m2
Supor EAV media Single-layer PES 0.2 µm bioburden reduction Mini Kleenpak syringe filters 2.8 cm2
Mini Kleenpak 20 capsules 20 cm2
Mini Kleenpak capsules 260 cm2
Kleenpak capsules 2100 cm2
Kleenpak Nova capsules 1.1–3.2 m2

Results and discussion

Filter screening

This work started with prefilter screening using an adherent LV crude harvest pool with a turbidity of 38.5 NTU and LV concentration of 3.7 × 107 IP/mL. Based on the work covered in (1), the PreFlow UB resin-bonded glass fiber filter was included. Because the turbidity of this pool was significantly higher than in previous work, two cellulose-based depth filters were also included— a V100P and a PDK11 filter. Note that the PDK11 is a dual-layer filter made up of a K900P layer on top of a V100P layer. More information on the prefilters can be found in Table 1.

Lentivirus crude harvest was loaded over the prefilters at a constant flux of 200 LMH. Pressure vs loading data can be seen in Figure 1. The data revealed similar capacities for the PreFlow UB and V100P prefilters at approximately 250 L/m2. The PDK11 provided a ~ four-fold higher capacity, achieving 1000 L/m2 throughput before reaching 0.7 bar (10 psi, 0.07 MPa).

Pressure drop vs loading for three prefilters loaded with adherent lentivirus crude harvest

Fig 1. Pressure drop vs loading for three prefilters loaded with adherent lentivirus crude harvest at 38.5 NTU.

Turbidity of the filtrate pools from the three prefilters can be seen in Figure 2. While all three prefilters reduced the turbidity below 5 NTU, the cellulose-based filters did show slightly lower turbidity levels than the PreFlow UB prefilter. This turbidity difference translated to capacity differences on the downstream membrane filters.

Pools from each prefilter were run over Supor EKV and EAV membrane filters in parallel. The capacities for those loaded with PreFlow UB prefilter filtrate were 34 and 32 L/m2, respectively.

In an earlier trial, a Fluorodyne™ II DBL membrane filter was also evaluated post PreFlow UB prefilter and had an even lower capacity under 10 L/m2. In contrast, the cellulose depth filtered pools led to membrane filter capacities between 390 and 480 L/m2.

Turbidity data from three prefilter options.

Fig 2. Turbidity data from three prefilter options.

The cellulose depth filter plus membrane filter combinations were evaluated for LV step yields (Fig 3). The V100P combinations appeared to have slightly higher yields. This could be expected, as the V100P prefilter is made without diatomaceous earth and a low charge resin, however more replicates will need to be run to determine if the difference is real and reproducible. Regarding the membrane filters, we did not observe a clear benefit for capacity or yield between the two tested here.

Comparison of lentiviral infectious particle step yields for the four combinations of cellulose depth filter and membrane filter

Fig 3. Comparison of lentiviral infectious particle step yields for the four combinations of cellulose depth filter and membrane filter. Error bars represent 95% confidence intervals.

Process robustness

Based on the balance between yield and capacity, the V100P prefilter was selected for additional testing. The Supor EKV membrane was selected as the membrane filter as it provides a sterile filtrate stream and showed no drop-off in capacity or yield. Two additional batches of adherent LV crude harvest were processed over the V100P + Supor EKV filters. Over the three runs, feed turbidity ranged from 20.2 to 72.9 NTU, feed concentration ranged from 3.7 ×107 to 1.2 × 108 IP/mL, and the step yield over the depth and membrane filter averaged 74%.

Prefilter pressure vs loading curves are presented in Figure 4 and reveal how feed turbidity can impact depth filter capacity. However, clarified pools showed consistently low turbidity averaging 2.7 NTU.

Footprint and sterility should be considered when selecting between the two as the Supor EKV filter is a validated sterilizing-grade filter, but the Supor EAV filter comes with more EFA per capsule as highlighted in Figure 5.

Pressure drop vs loading for V100P prefilters loaded with three batches of adherent lentivirus

Fig 4. Pressure drop vs loading for V100P prefilters loaded with three batches of adherent lentivirus crude harvest varying in turbidity.

Effective filter area (EFA) for Kleenpak Nova capsules containing Supor EKV and EAV membrane filters.

Fig 5. Effective filter area (EFA) for Kleenpak Nova capsules containing Supor EKV and EAV membrane filters.

Conclusions

We have previously shown strong clarification performance from a Supor EAV filter or PreFlow UB prefilter with a Fluorodyne II DBL filter combination, when loaded with adherent LV crude harvests under 15 NTU (1). Here, we have expanded upon that work and demonstrated that these filters can be replaced with cellulose-based depth filters in combination with Supor EKV and EAV membrane filters, when working with feeds at higher turbidities and/or containing higher levels of fine particles.

Comparing the V100P and PDK11 depth filter data here, we did not see a strong benefit from one over the other. The PDK11 did have a significantly higher capacity, but the benefit in terms of cost and footprint will likely be small as demonstrated in the scenario above. The V100P may have a slight yield benefit, however more data is needed to confirm this. Similarly, we did not see a strong difference between the two membrane filters tested.

References
  1. Raghavan M, Collins M, Walls S, Lambropoulos A, Bergheim-Pietza S. Development of gene therapy purification processes. Cell Gene Ther. Insights 2019;5:1311-1322.


CY61967

Ready to see more filtration solutions?
Explore our wide range of filtration products for your application

Did you find what you were looking for?