Chromatography modeling

Optimizing homodimer removal and aggregate reduction for a bispecific antibody using affinity chromatography

Oct 13, 2026

Employing MabSelect VL protein L to ease the burden on bispecific polishing

Bispecific antibodies (bsAb) are a class of therapeutics that can bind to two different target antigens, potentially promoting a more effective immunogenic response. However, their production can introduce challenges for chromatography separations due to the potential for various combinations of mispairings during upstream production. Different combinations of heavy and light chains can result in undesired homodimers, half-antibodies, or antibody fragments. In addition to the potential for extra product-related impurities, the production of bsAbs must also address the challenges faced in traditional monoclonal antibody (mAb) production, such as aggregate and host cell protein (HCP) clearance.

In this case study, we optimize a MabSelect™ VL resin capture process for a bsAb at laboratory scale using gradient elution runs to select conditions for step elution that remove the homodimer and light chain. The goal is to reach a high yield and purity during protein purification. We also explore if aggregate removal is feasible in the capture step, to lower the burden in the subsequent polishing step by employing mechanistic modeling. The investigated asymmetric bsAb features a single kappa light chain. The product-related impurities resulting from the cell expression systems were the homodimer of the molecule containing two kappa light chains and the kappa light chain fragment, all binding to the MabSelect VL chromatography resin.

Our MabSelect VL protein L resin is designed to specifically bind to antibodies that contain kappa light chain subclasses 1, 3, and 4. Importantly, the resin offers enhanced productivity and robustness, improved alkaline stability compared to its predecessor, Capto™ L resin, and demonstrates great selectivity for product-related impurities. Consequently, an affinity chromatography capture step using MabSelect VL resin can address the removal of product-related impurities without additional steps required for typical mAb processes.

bsAb affinity chromatography capture optimization

We performed laboratory experiments using a Tricorn™ 5/100 column packed with MabSelect VL protein L resin and an ÄKTA™ avant 25 chromatography system. First, we conducted a screening experiment to estimate the capacity and the selectivity of the resin using feed material. The loaded material exhibited 75% monomeric purity and was eluted with a 30 column volume (CV) gradient from pH 6 to pH 3 to evaluate the resolution of the bsAb and its impurities with the MabSelect VL resin (Fig 1). We then analyzed flowthrough and elution fractions using SEC-HPLC and/or chip electrophoresis to understand the elution profile of the bsAb and its impurities in detail.

Chromatogram and fraction analysis of the screening experiment with feed material

Fig 1. Chromatogram and fraction analysis of the screening experiment with feed material. To evaluate the resin selectivity a 30 CV pH gradient (pH 6.0 to pH 3.0, 20 mM citrate buffer) was performed. Load was approximate 76 g bsAb feed/L resin, residence time of 4 min. UV280 and pH on y-axis. SEC-HPLC and chip electrophoresis evaluation were used for offline analytics, shown in bars.


As can be seen in Figure 1, the UV trace at 280 nm shows high resolution, revealing the presence of at least three species (seen as three elution peaks) interacting with the MabSelect VL resin. Through offline analytics, we were able to identify four species: the desired heterodimer, its aggregates, a homodimer, and light chain fragments. The heterodimer containing one kappa light chain eluted first, followed by aggregates and homodimer that contained two kappa light chains, and lastly, the free kappa light chain.

Approximately 76 g bsAb feed/L resin was loaded; our MabSelect VL resin has a capacity of 60 g human IgG/L resin. A sizable amount of the target bsAb heterodimer was outcompeted in the loading phase by the product-related impurities. Table 1 presents the amount per liter of resin that was loaded and how much of each species was recovered. This data confirms that the heterodimer, which eluted first in a gradient, was displaced by other impurities that have higher avidity to the resin.

Analysis of the flowthrough gave a rough estimate of where breakthrough starts, however it was not sufficient to determine capacity. Therefore, the pure heterodimer was used for an exact determination of dynamic binding capacity (DBC) which resulted in 53 g/L resin, this was performed on a Tricorn™ 5/50 column. Since the target heterodimer is easily outcompeted by impurities, it was decided to operate at a significantly lower load. Due to the higher avidity of the impurities, the impurity composition has the potential to impact the determined binding capacity.

Table 1. Measured amounts of loaded and eluted material per liter of resin, along with recovery for each species

Total amount (g/L resin) Heterodimer Aggregates Homodimer Light chain
Load (g/L) 76 57.0 0.9 4.9 13.2
Elution (g/L) 45.6 30.0 0.5 3.6 11.4
Recovery (%) - 53 55 74 87

Using the results from the screening experiment (Fig 1), we designed a step elution to separate the heterodimer from the homodimer and light chain. We designed the step elution based on the UV trace and offline analytics. The chosen elution buffer has a pH of 3.77 (equal to 74.5% of B buffer) which corresponds to %B slightly before peak maximum, to achieve a successful separation of the heterodimer from the homodimer and light chain (Fig 2). We performed this experiment at a load of 30 g/L resin. With these step elution conditions we achieved a purity of 97.6% and a yield of 88.2% (Table 2).

Step elution experiment to separate the heterodimer from homodimer

Fig 2. Step elution experiment to separate the heterodimer from homodimer and light chain with step 1 at 74.5%B for 3 CV (corresponding to pH of 3.77) and step 2 at 100%B (corresponding to pH 3) for 5 CV. 30 g/L resin were loaded and a residence time of 4 min was used. UV280 and pH on y-axis. Each peak was analyzed by SEC-HPLC and RPC-HPLC.


Table 2. Yield, purity, and conditions for step elution to successfully separate the bsAb heterodimer from the homodimer and light chain

%B Elution buffer pH Step length (CV) Yield (%) Purity (%)
Step elution 74.5 3.77 3 88.2 97.6

Aggregate reduction during bsAb affinity chromatography capture

The goal of this experimental work was not just to separate homodimer and light chain from the heterodimer but also to investigate if the aggregates can be reduced during capture. Clearly, the coelution of the heterodimer and its aggregates illustrate a separation challenge. Therefore, we utilized a mechanistic model for optimizing the separation of aggregates, homodimer, and light chain from the bsAb heterodimer target.

After successful calibration and validation, we used the mechanistic model to determine optimal conditions for aggregate reduction in a bsAb capture step. The objective was to achieve a high yield and purity and reduce the aggregate content.

We used the same residence time (4 min), and sample load (30 g/L resin), as in the previous experiment. The process variables to be optimized by the mechanistic model were %B (elution buffer pH) and the elution length of the first elution step; the second elution step remains constant at 100%B (pH 3) and 5 CV.

We found the optimal process conditions were 65%B (equal to pH 4.07) with a 3.5 CV long first elution step (see Table 3). The predicted simulation curve demonstrates a satisfactory alignment with the experimentally measured UV trace (Fig 3). The predicted yield and purity accurately matched the measured pool content, with the optimized method achieving 99.2% purity and a yield of 82.7% (Table 4).

Table 3. Conditions for step elution to successfully separate the bsAb heterodimer from the homodimer and light chain, optimized with mechanistic modeling

%B Elution buffer pH Step length (CV)
Step elution 65 4.07 3.5

Optimized capture process step

Fig 3. Optimized capture process step using a 65%B step and step length of 3.5 CV to separate the desired bsAb from its impurities.


Table 4. Measured and predicted performance of the optimized capture step

Experiment Simulation
Starting material purity (%) 75 N/A
bsAb yield (%) 82.7 85.6
bsAb purity (%) 99.2 99.6
Remaining aggregate (%) 0.8 0.4

The potential risks associated with the optimized method can be investigated with mechanistic modeling. In silico robustness screening allows us to better understand how variation in the method, specifically in the elution pH (%B) and the step length, can affect heterodimer yield and purity. The robustness evaluation (Fig 4 A) shows that the same yield and purity can be achieved in the range of 63.4%B to 65.5%B which corresponds to pH 4.13 to pH 4.06 of the elution buffer. The step length has no impact on the process robustness. Yield and purity can also be investigated individually. A yield of 70% or above can be achieved at 63.4%B or higher corresponding to an elution buffer pH of 4.13 and below (Fig 4 B). Purity is above 98% when the %B is between 55 and 71% corresponding to an elution pH of 4.37 to 3.9 (Fig 4 C). Only the combined objective of yield and purity (Fig 4 A) gives the full picture and allows us to select robust process conditions.

Color scatterplot illustrating the influence of step length

Fig 4. Color scatterplot illustrating the influence of step length (CV) and step height (%B) which corresponds to the pH of the elution buffer on A) the composite objective function (which represents yield and purity), B) yield of the heterodimer, and C) purity of the heterodimer. The color gradient represents objective values, with green indicating more favorable outcomes and red indicating less favorable outcomes. The plot enables identification of optimal operating regions for the elution step.


An operating window of pH 4.13 to 4.06 of the elution pH, is considered too narrow for a robust process design where a safety margin of ± 0.1 pH units is desired. With the help of the robustness evaluation (Fig 4), we can identify a wider operating window. At an elution buffer pH of 4.0 ± 0.1 pH units, a yield ≥ 80%, a purity of at least 98.9%, and an aggregate reduction of at least 30% can be achieved.

With our two step elution design, we sacrificed yield to achieve higher purity during capture to reduce the strain on the subsequent polishing steps.

Comparison of both step runs

Two different step elution runs were performed, one based on a gradient elution experiment (Run 1 at elution pH 3.77 (74.5%B) and the other optimized with mechanistic modeling (Run 2 at elution pH 4.07 (65%B). The load consisted of 75% heterodimer, 1.2% aggregates, and a high amount of light chain and homodimer (Table 5). For Run 1, a yield of 88.2% and a heterodimer purity of 97.6% were achieved. Aggregate levels are slightly increased compared to the load material and both homodimer and light chain were reduced to below 1% but are still present. For Run 2, a yield of 82.7% and a heterodimer purity of 99.2% are accomplished. Furthermore, aggregate levels were reduced to 0.8% and homodimer and light chain were completely removed for Run 2.

Table 5. Comparison of yield and impurity profile of the eluate for the two performed step runs where Run 1 was based on a gradient elution experiment and Run 2 was optimized with mechanistic modeling

Aggregates (%) Heterodimer (%) Homodimer (%) Light chain (%) Yield (%)
Load 1.2 75.0 6.4 17.4 N/A
Run 1 at 75.5%B 1.3 97.6 0.7 0.04 88.2
Run 2 at 65%B 0.8 99.2 0 0 82.7

Designing the MabSelect VL resin step based on a gradient experiment emphasizes yield during bsAb capture (achieving 88%) at the cost of a lower purity (97.6%) and a more diverse impurity profile. This places the burden to remove remaining product-related impurities on the polishing steps. When using mechanistic modeling to optimize the capture step, 5.5% of yield is sacrificed (achieving 82.7%) to achieve a purity above 99% and to entirely remove the homodimer and light chain. This would ease the burden on the subsequent polishing step, meaning only the product-related impurity of aggregates would need to be removed, in addition to remaining process-related impurities which can be achieved with Capto™ adhere multimodal chromatography resin.

While making a decision based on a gradient experiment is fast when compared with the development of a mechanistic model, the model provides a depth of process knowledge which will allow for a more informative decision-making process when designing a capture step.

Conclusion

In summary, MabSelect VL resin demonstrates high selectivity to separate the heterodimer from the homodimer and light chain during the capture step, based on one gradient experiment. A reduction in aggregate content is also possible during the capture step by employing mechanistic modeling for process optimization.

When using MabSelect VL resin, we can choose to optimize yield during capture resulting in a more diverse impurity profile and a lower purity. This choice places the burden to remove remaining product-related impurities on the polishing steps. Alternatively, approximately 5% of yield can be sacrificed to achieve a purity > 99% and the complete removal of two product-related impurities. The latter method has the potential to enable a two-step elution protein purification process for bsAbs where the polishing step would only need to remove aggregates, HCPs and residual DNA.

MATERIALS AND METHODS

For all experiments, a bsAb with a Fc-Fab and a Fc-scFv design was used. The Fc-Fab contains a kappa light chain binding to MabSelect VL protein L resin. The feedstock has a protein concentration of around 3.8 g/L and a composition of 75.0% desired bsAb heterodimer, 1.2% aggregates, 6.4% Fc-Fab homodimer, and 17.4% light chain. The feed concentration was determined by injecting 1-5 mL feed onto MabSelect VL resin and the bound material was stripped off the column, and the concentration of the eluate was determined by UV absorbance.

The bsAb feed was captured on a MabSelect VL protein L resin. The resin was packed in a Tricorn 5/100 (2 mL) column and connected to an ÄKTA avant 25 chromatography system with a 2 mm UV cell.

Table 6 presents a high-level summary of the chromatographic method used. Equilibration was performed with 20 mM phosphate buffer and 150 mM sodium chloride at pH 7.4. The sample was then applied followed by a wash buffer with 20 mM phosphate and 500 mM sodium chloride at pH 7.0. The elution phase is divided into three steps; the first step, a buffer system exchange to 20 mM citrate buffer at pH 6.0. The second elution step involves decreasing the pH to 3 via gradient elution or step elution. The elution phase ends with a step at 20 mM citrate at pH 3. The packed column was then stripped with 500 mM acetic acid followed by a cleaning-in-place (CIP) phase with 100 mM sodium hydroxide. The last step was re-equilibration with 20 mM phosphate buffer and 150 mM sodium chloride at pH 7.4.

A screening experiment was performed at a load of approximately 76 g/L resin to estimate the capacity and investigate the selectivity for the heterodimer and the impurities present in the feed material. Fractions were analyzed by SEC-HPLC and LabChip (see analytical methods) since feed material was used, the UV trace could not be utilized for DBC determination. The screening experiment was eluted with a 30 CV gradient to provide initial information on the resin selectivity. To fully understand the impurity profile of this capture step, extensive fraction analysis was performed. Twenty three fractions were analyzed by SEC-HPLC and LabChip.

Table 6. Generalized MabSelect VL resin capture method

Method phase Buffer Duration
Equilibration 20 mM phosphate pH 7.4, 150 mM NaCl 3 CV
Sample application bsAb feed Experiment dependent
Wash 1 20 mM phosphate pH 7.0, 500 mM NaCl 5 CV
Wash 2 20 mM citrate buffer at pH 6 5 CV
Elution 20 mM citrate buffer at pH between 6 and 3 Experiment dependent, step or gradient
Wash at 100%B 20 mM citrate buffer at pH 3 5 CV
Strip 500 mM acetic acid 5 CV
CIP 100 mM NaOH 3 CV
Re-equilibration 20 mM phosphate pH 7.4, 150 mM NaCl 5 CV

The DBC at 10% breakthrough (QB10%), was determined for purified bsAb heterodimer by frontal analysis on resin packed in Tricorn™ 5/50 column. The sample was diluted to 2 mg/mL with 20 mM phosphate buffer and 150 mM sodium chloride at pH 7.4 and was applied to the column and DBC was calculated at 10% of the breakthrough capacity.

Analytical methods

During the elution phase, fractions of 1 or 2 mL were collected for offline analysis. The size exclusion chromatography (SEC) technique was used to determine the amount of aggregates, monomers, and light chains. The SEC method utilized a Superdex™ Increase GL 10/300 column with a running buffer of 200 mM potassium phosphate at pH 6.8, at a flow rate of 0.8 mL/min. Sample injections, 350 µg or less with a maximum volume of 100 µL, were performed, and peak area integration was used to calculate the percentages of aggregates, monomers, and light chains in each fraction. To differentiate between the monomers, heterodimer, and homodimers, either capillary electrophoresis or RPC-HPLC was used. For capillary electrophoresis, the Protein Express Assay LabChip and LabChip GXII protein characterization system (Revvity) were used. Manufacturer instructions were followed, and the analysis was performed by integration of the heterodimer and homodimer peaks to get the ratio between heterodimer and homodimer. The RPC method utilized a BioResolve RP mAb Polyphenyl column (Waters) to separate the heterodimer and homodimer in 0.1% formic acid or trifluoroacetic acid with a gradient of 0-100% acetonitrile. The flow rate was 0.5 mL/min at a temperature of 85ºC. The ratio of heterodimer and homodimer was combined with the SEC results to get the percentage of each species in the elution fractions. The HPLC system for SEC and RPC was Agilent Infinity II 1260 and 1290, respectively.

Mechanistic model calibration, validation and optimization

A mechanistic model is built on fundamental physicochemical principles, enhancing the understanding of underlying chromatographic processes. The model requires experimental data about the system and column used, as well as a few chromatography experiments with the target molecule for calibration.

The system and column were characterized according to system and column characterization guidelines for mechanistic model calibration.

The selected column model to be calibrated is an equilibrium dispersive model. While considering fluid dynamical effects like dispersion and convection effects, as well as the adsorptive interaction between the biomolecule and the resin surface in detail, the model lumps complex mass transfer phenomena together. A colloidal particle adsorption (CPA)-type affinity isotherm is selected to describe adsorption/desorption processes (1).

The model calibration was performed using the GoSilico chromatography modeling software. To accurately calibrate a mechanistic model, a set of four experiments were used to determine the interaction between the considered species and the MabSelect VL protein L resin. These experiments included two low-loaded linear gradient experiments (7 g/L resin, 10 CV and 30 CV gradient length), one step experiment at moderate loading conditions (14 g/L resin, 100%B, 10 CV), and one two-step experiment at high loading conditions (41 g/L resin, with the first step at 85%B, 3 CV and second step at 100%B, 5 CV). All calibration experiments were performed at a residence time of 4 min. The buffer compositions and concentrations are detailed in Table 6. An experimental overview is given in Table 7.

Table 7. Experiments used for model calibration. Fractions were analyzed with SEC-HPLC and chip electrophoresis

Calibration experiments Load amount (g/L resin) Number of fractions
10 CV linear gradient elution 7 8
30 CV linear gradient elution 7 12
Step elution: 100%B, 10 CV 14 7
Two-step elution: 85%B, 3 CV and 100%B, 5 CV 41 13

For the screening experiment and the model calibration experiments, less than 0.5 g of sample was used. Here, an extensive fraction analysis was undertaken to focus on modeling impurity behavior, in particular on aggregates. In total 40 fractions were analyzed for the model calibration experiments. For a focus on yield and purity only, fewer fractions and less experimental effort are sufficient.

The model calibration is illustrated with two representative calibration experiments in Figure 5. The first criterion to evaluate if a model is calibrated well enough involves comparing the overall UV traces obtained from the simulation and from the measured data. Subsequently, offline information that is accessible is also considered. This can be either virtual online analytics, that can be generated within the GoSilico software, by deconvoluting the measured chromatogram in the expected number of species eluting, or real offline analytics in the form of SEC fraction information. The simulated curve closely aligns with the experimental results for both experiments. These findings provide confirmation that the model has been effectively calibrated.

Two exemplary calibration experiments

Fig 5. Two exemplary calibration experiments. On the left side, a 10 CV low-loaded gradient experiment is depicted, while on the right side, a two-step experiment conducted at high loading conditions is shown. The upper row displays the UV 280 nm signal of the entire experimental method, providing an overview of the chromatographic profiles. The lower row presents the online analytics on the left and the offline analytics on the right, focusing specifically on a magnified view of the elution step. Solid lines represent the simulation and dashed lines the measurement.


After model calibration, the model needs to be validated. Therefore, we performed a two-step experiment with a longer residence time of 6 min (41 g/L resin loaded, first step at 85%B), illustrated in Figure 6. In addition to the excellent alignment between the simulated and measured total UV signal, the fraction information for all four species was accurately captured and well-simulated. Therefore, the capability of the model to predict and replicate the experimental outcomes with satisfactory precision is confirmed.

Two-step validation experiment following the same method as used for calibration

Fig 6. Two-step validation experiment following the same method as used for calibration while the residence time is increased to 6 min. Solid lines represent the simulation and dashed lines the measurement.


For optimizing the reduction of aggregates, the %B (representing the elution pH) and the phase length were optimized in silico. Flexible pooling conditions for in silico process optimization commence during the first elution step method phase, triggered when the UV 280 nm signal surpasses 50 mAU, and conclude when it drops below 500 mAU. The objective function used for optimization is high heterodimer yield and purity while minimizing aggregate and pool volume. Five hundred iterations were performed between set boundaries (50 to 80%B, 1 to 5 CV) using the adaptive simulated annealing algorithm. The optimized process was then validated in the laboratory.

To investigate potential risks associated with the optimized method, the mechanistic model is employed to investigate the process robustness. A sampling was performed where the %B (representing the buffer elution pH) and phase length were varied within the following ranges: 55 to 75%B and 2 to 5 CV respectively, to reveal how potentially critical process parameters affect yield, purity, or a specific objective.

 
REFERENCE
  1. Hahn T, Trunzer T, Rusly F, et al. Predictive scaling of fiber-based protein A capture chromatography using mechanistic modeling. Biotechnol.Bioeng. 2024: 121, 2388–2399. https://doi.org/10.1002/bit.28434
 