Shop in your local currency and language

Choose another country or region to see specific content for your location and shop online.

United Kingdom
Genomics

How to purify total RNA from plant leaves

Nov 4, 2026

Objective: Use a nucleic acid binding (NAB) Nanosep™ centrifugal filter to purify total RNA from plant leaf tissue.

Outcome: Recover purified total RNA for storage or concentration measurement.

Instruments

  • Microcentrifuge
  • Spectrophotometer
  • Vortex mixer
  • Pestle and mortar
  • Liquid nitrogen

Important points before starting

  • Clean all equipment and materials used for RNA extraction.
  • Perform all centrifugation steps at room temperature and 10 000–14 000 × g unless otherwise specified.
  • Work quickly and efficiently when handling RNA.
  • Use only the receiver tubes supplied with the NAB Nanosep™ filter inserts. Use enough supplied receiver tubes to complete the protocol.
  • Allow all buffers to equilibrate to room temperature before use.
  • After vortexing, briefly centrifuge the tubes to remove droplets from inside the lid.
  • Change pipette tips between all liquid transfers. Use sterile, RNA-free pipette tips.

Protocol

1. Prepare the sample

Weigh the plant leaf tissue. Do not use more than 100 mg.

2. Freeze and grind the tissue

Place the plant leaves in liquid nitrogen and immediately grind them to a powder using a pestle and mortar.

3. Transfer the powdered tissue

Transfer the powdered tissue to an RNase-free tube cooled with liquid nitrogen. Allow the liquid nitrogen to evaporate. Do not allow the tissue to thaw before continuing.

4. Add Buffer RLT

Add 350 µL Buffer RLT supplemented with DTT to the powdered sample.

5. Homogenize the sample

Using a syringe and needle, draw the lysate into the syringe and press the plunger to return it to the tube. Repeat approximately five times. Draw as much liquid lysate as possible into the syringe and transfer it to a clean RNase-free tube.

6. Clarify the lysate

Centrifuge for 2 min at 10 000–14 000 × g.

7. Transfer the supernatant

Transfer the supernatant to a clean RNase-free tube.

8. Add ethanol

Pulse-vortex the lysate for 30 s. Add 225 µL 100% ethanol and mix by pipetting.

9. Bind the RNA

Transfer 500 µL of lysed sample, including any precipitate, to the NAB Nanosep filter insert in a receiver tube.

10. Centrifuge the sample

Centrifuge for 60 s at 10 000–14 000 × g. Discard the flow-through and retain the receiver tube. If the sample volume is greater than 500 µL, process successive aliquots using the same NAB Nanosep filter insert. Discard the flow-through after each centrifugation and retain the receiver tube.

11. Perform optional DNase digestion

If DNA digestion is required, complete steps a–d below. Otherwise, continue to step 12.

  1. Add 350 µL Buffer RW1 to the NAB Nanosep filter insert. Centrifuge for 60 s at 10 000–14 000 × g. Discard the flow-through and retain the receiver tube.
  2. Add 10 µL prepared DNase I stock solution to 70 µL Buffer RDD. Mix by inverting the tube. Centrifuge for a few seconds to collect liquid from the sides of the tube.
  3. Pipette the prepared mixture directly onto the filter membrane. Incubate at room temperature for 15 min.
  4. Add 350 µL Buffer RW1. Centrifuge for 60 s at 10 000–14 000 × g. Discard the flow-through, retain the receiver tube, and continue to step 13.

12. Wash with Buffer RW1

Add 500 µL Buffer RW1 to the NAB Nanosep filter insert. Centrifuge for 60 s at 10 000–14 000 × g. Discard the flow-through and retain the receiver tube.

13. Wash with Buffer RPE

Add 500 µL Buffer RPE to the NAB Nanosep filter insert. Centrifuge for 60 s at 10 000–14 000 × g. Discard the flow-through and retain the receiver tube.

14. Repeat the Buffer RPE wash

Add another 500 µL Buffer RPE. Centrifuge for 2 min at 10 000–14 000 × g. Discard the flow-through and the receiver tube.

15. Dry the membrane

Place the NAB Nanosep filter insert in a clean supplied receiver tube. Centrifuge for 60 s at 10 000–14 000 × g to prevent Buffer RPE carryover. Discard the flow-through and the receiver tube.

16. Add the elution solution

Place the NAB Nanosep filter insert in the final clean supplied receiver tube. Add 50 µL RNase-free water or elution buffer directly to the center of the membrane.

17. Incubate

Close the lid and leave the filter to stand at room temperature for 1 min.

18. Elute the RNA

Centrifuge for 60 s at 10 000–14 000 × g to elute the RNA into the receiver tube.

19. Repeat the elution if required

Optional: Repeat the elution with a further 50 µL RNase-free water using the same NAB Nanosep filter insert and receiver tube.

Store the purified RNA

Store purified RNA in RNase-free water at −20°C or −70°C for up to 1 year.

Quantify the RNA

Determine RNA concentration by measuring absorbance at 260 nm (A₂₆₀) with a spectrophotometer. Photometric measurement can be difficult at low RNA concentrations; use fluorometric quantification for smaller quantities.

Use A₂₆₀ readings greater than 0.15. An absorbance reading of 1.0 at 260 nm corresponds to 44 µg RNA/mL. This relationship is valid only at neutral pH. If dilution is required, use a neutral-pH dilution buffer.

Preparations

Solution Preparation
Buffer RLT + DTT Add 20 µL DTT (2 M) per 1 mL Buffer RLT.
Buffer RLT Redissolve any precipitate.
Buffer RPE Before first use, add 100% ethanol. Use the volume stated on the bottle.
DNase I in Buffer RDD (optional) Dissolve DNase I in dH₂O. Mix 10 µL dissolved DNase I with 70 µL Buffer RDD.

Materials

Use nuclease-free consumables and reagents where available.

Consumables

Supplier Product description Product code
Cytiva Nucleic acid binding (NAB) Nanosep centrifugal filter ODNABC33, ODNABC34
VWR Ethanol, not denatured 71001-866
VWR Spectrophotometer cuvettes, approximately 100 µL (260/280 nm) 47743-840
VWR 15 mL tubes, RNase- and DNase-free 89401-574
VWR 50 mL tubes, RNase- and DNase-free 89401-572
VWR 1.5 mL microcentrifuge tubes, RNase- and DNase-free 76005-210
VWR Needles, 20 gauge (0.9 mm) 89219-312
VWR 10 mL syringe 89215-218

Reagents

Supplier Product description Product code
Qiagen Proteinase K 19131
Qiagen DNase I set 79254 / 79256
Qiagen Buffer RLT 79216
Qiagen Buffer RPE 1018013
Qiagen Buffer RDD 1011132
Qiagen Buffer RW1 1053394
Qiagen Nuclease-free water 129115
Thermo Fisher TE buffer, pH 7.5 J75893-AE
VWR Tris buffer, pH 7.0 (1 M) 89500-584
VWR Lysozyme 97062-136
VWR DTT (25 g) 97063-758

Product information

View the current Cytiva Nanosep centrifugal filter range: Nanosep centrifugal filters

Find the right Nanosep centrifugal filter
Explore Nanosep centrifugal filters for rapid processing of 50 to 500 µL samples and select the filter medium, pore size or MWCO, and pack size for your workflow.

Did you find what you were looking for?