Objective: Use a nucleic acid binding (NAB) Nanosep™ centrifugal filter to purify total RNA from plant leaf tissue.
Outcome: Recover purified total RNA for storage or concentration measurement.
Instruments
- Microcentrifuge
- Spectrophotometer
- Vortex mixer
- Pestle and mortar
- Liquid nitrogen
Important points before starting
- Clean all equipment and materials used for RNA extraction.
- Perform all centrifugation steps at room temperature and 10 000–14 000 × g unless otherwise specified.
- Work quickly and efficiently when handling RNA.
- Use only the receiver tubes supplied with the NAB Nanosep™ filter inserts. Use enough supplied receiver tubes to complete the protocol.
- Allow all buffers to equilibrate to room temperature before use.
- After vortexing, briefly centrifuge the tubes to remove droplets from inside the lid.
- Change pipette tips between all liquid transfers. Use sterile, RNA-free pipette tips.
Protocol
1. Prepare the sample
Weigh the plant leaf tissue. Do not use more than 100 mg.
2. Freeze and grind the tissue
Place the plant leaves in liquid nitrogen and immediately grind them to a powder using a pestle and mortar.
3. Transfer the powdered tissue
Transfer the powdered tissue to an RNase-free tube cooled with liquid nitrogen. Allow the liquid nitrogen to evaporate. Do not allow the tissue to thaw before continuing.
4. Add Buffer RLT
Add 350 µL Buffer RLT supplemented with DTT to the powdered sample.
5. Homogenize the sample
Using a syringe and needle, draw the lysate into the syringe and press the plunger to return it to the tube. Repeat approximately five times. Draw as much liquid lysate as possible into the syringe and transfer it to a clean RNase-free tube.
6. Clarify the lysate
Centrifuge for 2 min at 10 000–14 000 × g.
7. Transfer the supernatant
Transfer the supernatant to a clean RNase-free tube.
8. Add ethanol
Pulse-vortex the lysate for 30 s. Add 225 µL 100% ethanol and mix by pipetting.
9. Bind the RNA
Transfer 500 µL of lysed sample, including any precipitate, to the NAB Nanosep filter insert in a receiver tube.
10. Centrifuge the sample
Centrifuge for 60 s at 10 000–14 000 × g. Discard the flow-through and retain the receiver tube. If the sample volume is greater than 500 µL, process successive aliquots using the same NAB Nanosep filter insert. Discard the flow-through after each centrifugation and retain the receiver tube.
11. Perform optional DNase digestion
If DNA digestion is required, complete steps a–d below. Otherwise, continue to step 12.
- Add 350 µL Buffer RW1 to the NAB Nanosep filter insert. Centrifuge for 60 s at 10 000–14 000 × g. Discard the flow-through and retain the receiver tube.
- Add 10 µL prepared DNase I stock solution to 70 µL Buffer RDD. Mix by inverting the tube. Centrifuge for a few seconds to collect liquid from the sides of the tube.
- Pipette the prepared mixture directly onto the filter membrane. Incubate at room temperature for 15 min.
- Add 350 µL Buffer RW1. Centrifuge for 60 s at 10 000–14 000 × g. Discard the flow-through, retain the receiver tube, and continue to step 13.
12. Wash with Buffer RW1
Add 500 µL Buffer RW1 to the NAB Nanosep filter insert. Centrifuge for 60 s at 10 000–14 000 × g. Discard the flow-through and retain the receiver tube.
13. Wash with Buffer RPE
Add 500 µL Buffer RPE to the NAB Nanosep filter insert. Centrifuge for 60 s at 10 000–14 000 × g. Discard the flow-through and retain the receiver tube.
14. Repeat the Buffer RPE wash
Add another 500 µL Buffer RPE. Centrifuge for 2 min at 10 000–14 000 × g. Discard the flow-through and the receiver tube.
15. Dry the membrane
Place the NAB Nanosep filter insert in a clean supplied receiver tube. Centrifuge for 60 s at 10 000–14 000 × g to prevent Buffer RPE carryover. Discard the flow-through and the receiver tube.
16. Add the elution solution
Place the NAB Nanosep filter insert in the final clean supplied receiver tube. Add 50 µL RNase-free water or elution buffer directly to the center of the membrane.
17. Incubate
Close the lid and leave the filter to stand at room temperature for 1 min.
18. Elute the RNA
Centrifuge for 60 s at 10 000–14 000 × g to elute the RNA into the receiver tube.
19. Repeat the elution if required
Optional: Repeat the elution with a further 50 µL RNase-free water using the same NAB Nanosep filter insert and receiver tube.
Store the purified RNA
Store purified RNA in RNase-free water at −20°C or −70°C for up to 1 year.
Quantify the RNA
Determine RNA concentration by measuring absorbance at 260 nm (A₂₆₀) with a spectrophotometer. Photometric measurement can be difficult at low RNA concentrations; use fluorometric quantification for smaller quantities.
Use A₂₆₀ readings greater than 0.15. An absorbance reading of 1.0 at 260 nm corresponds to 44 µg RNA/mL. This relationship is valid only at neutral pH. If dilution is required, use a neutral-pH dilution buffer.
Preparations
| Solution | Preparation |
|---|---|
| Buffer RLT + DTT | Add 20 µL DTT (2 M) per 1 mL Buffer RLT. |
| Buffer RLT | Redissolve any precipitate. |
| Buffer RPE | Before first use, add 100% ethanol. Use the volume stated on the bottle. |
| DNase I in Buffer RDD (optional) | Dissolve DNase I in dH₂O. Mix 10 µL dissolved DNase I with 70 µL Buffer RDD. |
Materials
Use nuclease-free consumables and reagents where available.
Consumables
| Supplier | Product description | Product code |
|---|---|---|
| Cytiva | Nucleic acid binding (NAB) Nanosep centrifugal filter | ODNABC33, ODNABC34 |
| VWR | Ethanol, not denatured | 71001-866 |
| VWR | Spectrophotometer cuvettes, approximately 100 µL (260/280 nm) | 47743-840 |
| VWR | 15 mL tubes, RNase- and DNase-free | 89401-574 |
| VWR | 50 mL tubes, RNase- and DNase-free | 89401-572 |
| VWR | 1.5 mL microcentrifuge tubes, RNase- and DNase-free | 76005-210 |
| VWR | Needles, 20 gauge (0.9 mm) | 89219-312 |
| VWR | 10 mL syringe | 89215-218 |
Reagents
| Supplier | Product description | Product code |
|---|---|---|
| Qiagen | Proteinase K | 19131 |
| Qiagen | DNase I set | 79254 / 79256 |
| Qiagen | Buffer RLT | 79216 |
| Qiagen | Buffer RPE | 1018013 |
| Qiagen | Buffer RDD | 1011132 |
| Qiagen | Buffer RW1 | 1053394 |
| Qiagen | Nuclease-free water | 129115 |
| Thermo Fisher | TE buffer, pH 7.5 | J75893-AE |
| VWR | Tris buffer, pH 7.0 (1 M) | 89500-584 |
| VWR | Lysozyme | 97062-136 |
| VWR | DTT (25 g) | 97063-758 |
Product information
View the current Cytiva Nanosep centrifugal filter range: Nanosep centrifugal filters