They are pre-measured ECL tablets for HRP-based Western blot detection. One Tablet A and one Tablet B prepare 5 mL of fresh detection reagent.
Easy tab ECL prime tablets
Pre-measured, single-use tablet reagent that delivers fresh, ready-to-use ECL in minutes.
Overview
Get high-performance enhanced chemiluminescence (ECL) on demand in a convenient tablet format. Two tablets (A and B) create a pre-measured dose detection reagent in under 10 minutes, eliminating pipetting errors, variability, reagent waste and risks for contamination.
- Premeasured, single-use tablet format eliminates manual mixing and pipetting steps, delivering consistent results regardless of your experience.
- Proven femtogram-level sensitivity matches trusted Amersham™ ECL Prime solution performance, enabling confident detection of low-abundance proteins.
- Long-lasting signal stability of up to 24 h supports flexible reimaging schedules and processing of multiple blots in large experimental series.
- Fresh ECL reagent generated on demand ensures optimal chemistry for each experiment, reducing the risk of using contaminated or degraded reagents.
Signal sensitivity
Easy tab ECL prime tablets deliver femtogram-level detection capability.
Fig 1. Slot-blot of an α-rabbit HRP dilution series, showing femtogram-level detection down to 94 fg developed using Easy tab ECL prime tablets.
Signal stability and duration
Easy tab ECL prime tablets perform on par with Amersham ECL Prime detection reagents with femtogram-level sensitivity and long signal stability.
Fig 2. Signal duration and stability on Protran™ membranes for Easy tab ECL prime tablet
Membrane compatibility
Easy tab ECL tablets deliver consistent, high-sensitivity detection across both PVDF and nitrocellulose membranes.
Fig 3. Membrane comparison of Easy tab ECL prime detection on PVDF (top) versus NC (bottom). A-431 lysate (5 mg/mL) was serially diluted from 0.25 mg/mL down to 0.016 mg/mL and transferred in parallel onto 0.45 μm PVDF (top row) and Protran NC (bottom row) membranes.
Preparation of working solution
- Add one tablet A (luminol) and one tablet B (peroxide) to 5 mL of deionized water in a suitable container
- Dissolve at room temperature (approximately 8 min).
- Apply dissolved ECL mixture to the membrane and image.
Tip: Place the container on a tilting or rotating table to help the tablets fully dissolve.
Sustainability
Traditional liquid ECL detection reagents require the shipment of 100 mL of aqueous solution in two plastic bottles, all of which must be kept under refrigerated conditions throughout transport. Easy tab replaces this with compact, dry tablets that you reconstitute in distilled water prior to use. This simple change removes the liquid from the supply chain entirely, delivering measurable reductions across multiple sustainability metrics:
- Approximately 67% reduction in total shipped weight by eliminating solutions and replacing plastic bottles with a compact blister pack.
- Up to 80% reduction in plastic packaging compared to traditional two-bottle liquid ECL formats.
- Approximately 87% reduction in package volume, enabling significantly more packs per pallet and fewer shipments per order cycle.