FAQ

Spare parts

Please note:

Item numbers in gray illustrates parts in contact with process stream/or that are pressure retaining.

Item numbers are not necessarily in sequential order.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
114 O-ring 142x3 mm 28942104 190.89 USD Add to cart
Get Quote
115 Tube support AxiChrom 140 column 28942035 334.00 USD Add to cart
Get Quote
118 Check valve and housing, TC25 28983704 232.00 USD Add to cart
Get Quote
119 Washer 10.5x20 mm 28942132 138.87 USD Add to cart
Get Quote
124 Check valve adapter 28401978 116.85 USD Add to cart
Get Quote
201 Glass tube short 28941873 2 984.00 USD Add to cart
Get Quote
201 Glass tube long 28941876 4 016.00 USD Add to cart
Get Quote
804 Top flange AxiCh 140 28985791 1 100.00 USD Add to cart
Get Quote
805 Bottom flange AxiChrom 140 column 28941856 1 411.00 USD Add to cart
Get Quote
806 Nut, M10 18101244 22.67 USD Add to cart
Get Quote
901 Extender rod for short column tube AxiChrom 28941865 621.00 USD Add to cart
Get Quote
901 Extender rod for long column tube AxiChrom 28941868 643.00 USD Add to cart
Get Quote

Please note:

Item numbers in gray illustrates parts in contact with process stream/or that are pressure retaining.

Item numbers are not necessarily in sequential order.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
127 O-ring 99.5x3 mm 28942012 57.40 USD Add to cart
Get Quote
301 Bed support 140 top/bottom 20mikrom PE 28981525 799.00 USD Add to cart
Get Quote
301 Bed support 140 top/bottom 10mikrom UHMWPE 28981526 803.00 USD Add to cart
Get Quote
401 O-ring 3.69x1.78 mm 28932992 224.00 USD Add to cart
Get Quote
401 Fastener kit for adaptor 28942112 232.00 USD Add to cart
Get Quote
402 Distributor 140 top, PE bed support 28981513 1 221.00 USD Add to cart
Get Quote
403 Hex socket head screw M4x35 28942123 199.52 USD Add to cart
Get Quote
404 Distributor 140 bottom, PE bed support 28981514 1 242.00 USD Add to cart
Get Quote
421 Snap ring 140 top/bottom, PE bed support 28981522 467.00 USD Add to cart
Get Quote
501 Adaptor plate AxiCh 140 28985788 627.00 USD Add to cart
Get Quote
502 Bottom plate 28941802 1 255.00 USD Add to cart
Get Quote
604 O-ring 127.0x5.33 mm 28942010 110.38 USD Add to cart
Get Quote
605 Scraper AxiChrom 140 column 28942007 474.00 USD Add to cart
Get Quote

O-rings should be checked regularly for wear and replaced when needed or at least annually. Worn O-rings may not seal properly. Please keep a set of each on your site to prevent long downtime. For code numbers refer to the table below.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Top gasket AxiChrom 140 and 200 columns 28942039 89.54 USD Add to cart
Get Quote
2 O-ring 26.64x2.62 mm 28942110 18.68 USD Add to cart
Get Quote
3 O-ring 145.6x3.53 mm 28942106 52.98 USD Add to cart
Get Quote
4 Adaptor tube for AxiChrom 140 28941883 1 793.00 USD Add to cart
Get Quote
5 O-ring 76 x 4 mm EPDM 28942108 79.61 USD Add to cart
Get Quote
6 Fastener kit for adaptor 28942112 232.00 USD Add to cart
Get Quote
7 Check valve and housing, TC25 28983704 232.00 USD Add to cart
Get Quote
8 TC Clamp kit TC25/SS 28404338 120.33 USD Add to cart
Get Quote
10 Bed support adaptor AxiChrom 140, 10 µm 28941974 3 587.00 USD Add to cart
Get Quote
11 Bed support adaptor AxiChrom 140, 20 µm 28941995 3 591.00 USD Add to cart
Get Quote
12 Bed support 140 top/bottom 20mikrom PE 28981525 799.00 USD Add to cart
Get Quote
13 Bed support bottom AxiChrom 140, 10 µm 28941997 3 587.00 USD Add to cart
Get Quote
14 Bed support bottom AxiChrom 140, 20 µm 28941999 3 354.00 USD Add to cart
Get Quote
15 O-ring 6.02x2.62 mm 28926895 142.31 USD Add to cart
Get Quote
16 O-ring 99.5x3 mm 28942012 57.40 USD Add to cart
Get Quote
17 O-ring 127.0x5.33 mm 28942010 110.38 USD Add to cart
Get Quote
18 Scraper AxiChrom 140 column 28942007 474.00 USD Add to cart
Get Quote
20 TC-gasket 25/8 EPDM 28950948 61.81 USD Add to cart
Get Quote
21 Mounting aid for O-rings 28924749 13.55 USD Add to cart
Get Quote

Please note:

Item numbers in gray illustrates parts in contact with process stream/or that are pressure retaining.

Item numbers are not necessarily in sequential order.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
102 Guide ring AxiChrom 140 and 200 columns 28942042 90.82 USD Add to cart
Get Quote
103 Top gasket AxiChrom 140 and 200 columns 28942039 89.54 USD Add to cart
Get Quote
104 O-ring 26.64x2.62 mm 28942110 18.68 USD Add to cart
Get Quote
105 Adaptor rod top AxiChrom 140 and 200 columns 28942034 472.00 USD Add to cart
Get Quote
106 Set screw M4x5 mm 28401976 72.31 USD Add to cart
Get Quote
107 Purge valve kit AxiChrom 140 and 200 28942102 238.00 USD Add to cart
Get Quote
108 O-ring 145.6x3.53 mm 28942106 52.98 USD Add to cart
Get Quote
110 Adaptor tube for AxiChrom 140 28941883 1 793.00 USD Add to cart
Get Quote
111 O-ring 76 x 4 mm EPDM 28942108 79.61 USD Add to cart
Get Quote
602 O-ring 6.02x2.62 mm 28926895 142.31 USD Add to cart
Get Quote
802 Adaptor rod AxiCh 140/200 28985789 1 251.00 USD Add to cart
Get Quote
803 Top plate AxiCh 140 28985790 961.00 USD Add to cart
Get Quote
807 Hex socket head screw M6x10 28942121 195.91 USD Add to cart
Get Quote

Please note:

Item numbers in gray illustrates parts in contact with process stream/or that are pressure retaining.

Item numbers are not necessarily in sequential order.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
125 Washer 8.4x16 mm 28942138 197.99 USD Add to cart
Get Quote
801 Hex socket head screw M8x20 mm 28942116 196.88 USD Add to cart
Get Quote
808 Hex head screw M8x20 28942119 196.73 USD Add to cart
Get Quote

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Tool kit small AxiChrom 50–200 28936136 549.00 USD Add to cart
Get Quote
2 Tool Kit Complete for AxiChrom 50–200 Columns 28944261 1 637.00 USD Add to cart
Get Quote
3 Torque Wrench Kit for AxiChrom Columns 28936137 481.00 USD Add to cart
Get Quote
4 Torque Driver Kit for AxiChrom Columns 28936139 1 117.00 USD Add to cart
Get Quote
5 Mounting aid for O-rings 28924749 13.55 USD Add to cart
Get Quote
7 Bayonet tool 28401390 91.72 USD Add to cart
Get Quote
8 Hook wrench key 28907141 119.72 USD Add to cart
Get Quote

Please note:

Item numbers in gray illustrates parts in contact with process stream/or that are pressure retaining.

Item numbers are not necessarily in sequential order.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
130 TC Clamp kit TC25/SS 28404338 120.33 USD Add to cart
Get Quote
131 TC end cap 28966791 324.00 USD Add to cart
Get Quote
132 ÄKTApilot O-Ring, 3 × 1 mm 18116912 661.00 USD Add to cart
Get Quote
132 Connector, 25 mm TC - UNF 5/16" Male, short 18117008 169.94 USD Add to cart
Get Quote
608 TC-gasket kit 25 mm i.d. 6.5 mm 28966737 47.19 USD Add to cart
Get Quote
610 TC-gasket 25/8 EPDM 28950948 61.81 USD Add to cart
Get Quote
702 Hex socket head screw M8x12 28944567 63.19 USD Add to cart
Get Quote

Figure 4. Stainless steel bed supports

 

Please note:

Item numbers in gray illustrates parts in contact with process stream/or that are pressure retaining.

Item numbers are not necessarily in sequential order.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
112 O-ring 3.69x1.78 mm 28932992 224.00 USD Add to cart
Get Quote
112 Fastener kit for adaptor 28942112 232.00 USD Add to cart
Get Quote
301 Bed support adaptor AxiChrom 140, 10 µm 28941974 3 587.00 USD Add to cart
Get Quote
301 Bed support adaptor AxiChrom 140, 20 µm 28941995 3 591.00 USD Add to cart
Get Quote
302 Bed support bottom AxiChrom 140, 10 µm 28941997 3 587.00 USD Add to cart
Get Quote
302 Bed support bottom AxiChrom 140, 20 µm 28941999 3 354.00 USD Add to cart
Get Quote
402 End cell top 28942001 1 341.00 USD Add to cart
Get Quote
403 Hex socket head screw M4x35 28942123 199.52 USD Add to cart
Get Quote
404 End cell bottom AxiChrom 140 column 28942004 1 401.00 USD Add to cart
Get Quote
501 Adaptor plate AxiCh 140 28985788 627.00 USD Add to cart
Get Quote
502 Bottom plate 28941802 1 255.00 USD Add to cart
Get Quote
603 O-ring 99.5x3 mm 28942012 57.40 USD Add to cart
Get Quote
604 O-ring 127.0x5.33 mm 28942010 110.38 USD Add to cart
Get Quote
605 Scraper AxiChrom 140 column 28942007 474.00 USD Add to cart
Get Quote

Accessories

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
4 6 bar rupture disc kit for AxiChrom 200 28978006 2 156.00 USD Add to cart
Get Quote
5 8 bar rupture disc kit for AxiChrom 140 28978012 2 160.00 USD Add to cart
Get Quote
6 Rupture disc 6 bar, TC50 28978183 1 744.00 USD Add to cart
Get Quote
7 Rupture disc 8 bar, TC50 28978184 1 537.00 USD Add to cart
Get Quote

Item Comment
1

For flow rates 3 l/h-175 l/h use Low Flow Kit 28-9301-82.

For flow rates 7.5 l/h-510 l/h use High Flow Kit 28-9301-83.

2 For appropriate tubing i.d. refer to table below.
3 TC Gasket 25 mm i.d. 15 mm 44-5492-88, gaskets supplied with the flow kit. Two gaskets i.d. 15 mm needed to connect the column to the flow kit.
4 TC Clamp 25 mm, 28-4043-38 (Stainless steel) or 28-4043-36 (Polypropylene). Four clamps needed to connect to system.
5

TC Gasket Kit 25 mm, i.d. 6.5 mm, 28-9667-37. Two gaskets i.d. 6.5 mm needed to connect the column to the system.

6 TC End Cap, 25 mm TC, 28-9667-91.
7 Connector, 25 mm TC - UNF 5/16" Male, short, 18-1170-08.
8 O-Ring, 3 × 1 mm 18-1169-12.

To isolate the column from the system use 2-port, 2-way Valve i.d. 6 mm, 44-5501-00 (left) or 44-5501-01 (right) or alternatively only TC End Cap, 25 mm TC, 28-9667-91, TC Clamp 25 mm and a gasket. Please verify that the pack sizes of clamps and gaskets correspond to your needs.

 

Tubing

Column Tubing i.d. Tubing connection
AxiChrom 140 3.2 mm1 or 4.8 mm2 25 mm TC
AxiChrom 200 6.4 mm 25 mm TC

1 It is recommended to use tubing with id 3.2 mm for media with an approximate bead size < 50 µm.

2 For media with an approximate bead size > 50 µm it is recommended to use tubing with id 4.8 mm.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
3 TC-Gasket 25 mm i.d. 15 mm 44549288 169.54 USD Add to cart
Get Quote
4 TC clamp kit, 25 mm TC 28404336 245.00 USD Add to cart
Get Quote
4 TC Clamp kit TC25/SS 28404338 120.33 USD Add to cart
Get Quote
5 TC-gasket kit 25 mm i.d. 6.5 mm 28966737 47.19 USD Add to cart
Get Quote
6 TC end cap 28966791 324.00 USD Add to cart
Get Quote
7 Connector, 25 mm TC - UNF 5/16" Male, short 18117008 169.94 USD Add to cart
Get Quote
8 ÄKTApilot O-Ring, 3 × 1 mm 18116912 661.00 USD Add to cart
Get Quote
2 port, 2 way valves i.d. 6 mm (left) 44550100 418.00 USD Add to cart
Get Quote
2 port, 2 way valves i.d. 6 mm (right) 44550101 409.00 USD Add to cart
Get Quote

Figure. Tubing kits and connections for ÄKTAprocess.

Table. Tubing kits and connections for ÄKTAprocess.

Pos. Tubing kit AxiChrom 140, i.d. 3.21 Tubing kit AxiChrom 140, i.d. 4.82 Tubing Connections
1 i.d. 3.2 / L=2000 i.d. 4.8/L=2000

Inlet CIP1 ÄKTAprocess

 -> Column top mobile phase inlet/outlet

2 i.d. 3.2 / L=1000 i.d. 4.8 / L=1000

ÄKTAprocess Column Bottom

 -> Column bottom mobile phase inlet/outlet

3 i.d. 4.8 / L=1600 i.d. 4.8 / L=1600 Inlet CIP2-> Column check valve
4 i.d. 6.4 / L=2000 i.d. 6.4 / L=2000 Column hydraulic chamber outlet
5 TC Gasket 25 mm i.d. 6.5 mm3 (10 x Gasket supplied with the tubing kit) TC Gasket 25 mm i.d. 6.5 mm3 (10 x Gasket supplied with the tubing kit)  
6 TC Gasket 25 mm i.d. 8.0 mm4 (2 x Gasket supplied with the tubing kit) TC Gasket 25 mm i.d. 8.0 mm4 (2 x Gasket supplied with the tubing kit)  
7 25 mm TC Clamp5
(7 x Clamp in steel supplied with the tubing kit)
25 mm TC Clamp5
(7 x Clamp in steel supplied with the tubing kit)
 

1 It is recommended to use tubing with id 3.2 mm for media with an approximate bead size < 50μm.
2 For media with an approximate bead size > 50μm it is recommended to use tubing with id 4.8 mm.
3 Use if at least one of the connecting ends is made of plastic.
4 When both ends are made of metal stronger force can be applied to the clamp and therefore reduce the original inner diameter of the gasket. We recommend you to use the gasket with larger inner diameter if both connecting ends are made of metal.
5 Use plastic clamp if at least one of the connecting ends is made of plastic, clamp 25 mm TC in polypropylene, 28-4043-36.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Tubing Kit i.d. 3.2 mm for Connecting AxiChrom 140 to ÄKTAprocess, silicone 28942986 2 089.00 USD Add to cart
Get Quote
1 Tubing Kit i.d. 4.8 mm for Connecting AxiChrom 140 to ÄKTAprocess, silicone 28942993 2 138.00 USD Add to cart
Get Quote
1 TC-gasket 25/8 EPDM 28950948 61.81 USD Add to cart
Get Quote
1 TC-gasket kit 25 mm i.d. 6.5 mm 28966737 47.19 USD Add to cart
Get Quote
2 TC-gasket kit 25 mm i.d. 6.5 mm 28966737 47.19 USD Add to cart
Get Quote
6 TC-gasket 25/8 EPDM 28950948 61.81 USD Add to cart
Get Quote
7 TC clamp kit, 25 mm TC 28404336 245.00 USD Add to cart
Get Quote
7 TC Clamp kit TC25/SS 28404338 120.33 USD Add to cart
Get Quote

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Mechanical Locking, AxiChrom 140 28943388 953.00 USD Add to cart
Get Quote
2 Tubing Kit i.d. 3.2 mm for Connecting AxiChrom 140 to ÄKTAprocess, silicone 28942986 2 089.00 USD Add to cart
Get Quote
3 Tubing Kit i.d. 4.8 mm for Connecting AxiChrom 140 to ÄKTAprocess, silicone 28942993 2 138.00 USD Add to cart
Get Quote
4 TC Clamp kit TC25/SS 28404338 120.33 USD Add to cart
Get Quote
5 TC-gasket kit 25 mm i.d. 6.5 mm 28966737 47.19 USD Add to cart
Get Quote
6 TC end cap 28966791 324.00 USD Add to cart
Get Quote
7 Media Stirrer, 80 mm diameter 28919103 214.00 USD Add to cart
Get Quote
8 Media Stirrer,150 mm diameter 28919104 253.00 USD Add to cart
Get Quote
9 Tool kit small AxiChrom 50–200 28936136 549.00 USD Add to cart
Get Quote
10 Tool Kit Complete for AxiChrom 50–200 Columns 28944261 1 637.00 USD Add to cart
Get Quote
11 Torque Wrench Kit for AxiChrom Columns 28936137 481.00 USD Add to cart
Get Quote
12 Torque Driver Kit for AxiChrom Columns 28936139 1 117.00 USD Add to cart
Get Quote
13 Outlet Tubing Kit, AxiChrom 140 and 200 columns 28943041 647.00 USD Add to cart
Get Quote

Accessories for connecting AxiChrom 140 to ÄKTApilot system

Figure. Tubing kits and connections for ÄKTApilot.

Table. Tubing kits and connections for ÄKTApilot.

Pos. Tubing kit AxiChrom 140, i.d. 3.21 Tubing kit AxiChrom 140, i.d. 4.82 Tubing Connections
1 i.d. 3.2 / L=1600 i.d. 4.8 / L=1600 Connect tubing 1 from the column top to position 3 on valve 7 (V7)
2 i.d. 3.2 / L=1600 i.d. 4.8 / L=1600 Connect tubing 2 from the hydraulic chamber to position 1 on valve 7 (V7)
3 i.d. 4.8 / L=1600 i.d. 4.8 / L=1600 Connect tubing 3 from the column bottom to position 3 on valve 6 (V6)
4 i.d. 6.4 / L=2000 i.d. 4.8 / L=2000  
5 TC Gasket 25 mm i.d. 6.5 mm3 (10 x Gasket supplied with the tubing kit) TC Gasket 25 mm i.d. 6.5 mm3 (10 x Gasket supplied with the tubing kit)  
6 TC Gasket 25 mm i.d. 8.0 mm4 (2 x Gasket supplied with the tubing kit) TC Gasket 25 mm i.d. 8.0 mm4 (2 x Gasket supplied with the tubing kit)  
7 25 mm TC Clamp5
(7 x Clamp in steel supplied with the tubing kit)
25 mm TC Clamp5
(7 x Clamp in steel supplied with the tubing kit)
 
8 Connector 5/16" short, supplied with the tubing kit Connector 5/16" short, supplied with the tubing kit  

1 Use tubing with i.d. 3.2 mm for media with an approximate bead size < 50μm.
2 Use tubing with i.d. 4.8 mm for media with an approximate bead size > 50μm.
3 Use if at least one of the connecting ends is made of plastic.
4 Use if both connecting ends are made of metal.
5 Use plastic clamp if at least one of the connecting ends is made of plastic.

Note: The tubing internal diameters for connection between column and ÄKTApilot are the same as for ÄKTAprocess.

 

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Silicone tubing kit AxiChrom 140, i.d. 4.8 mm ÄKTApilot 28977958 2 786.00 USD Add to cart
Get Quote
1 Silicone tubing kit AxiChrom 140, i.d. 3.2 mm ÄKTApilot 28977960 2 343.00 USD Add to cart
Get Quote
5 TC-gasket kit 25 mm i.d. 6.5 mm 28966737 47.19 USD Add to cart
Get Quote
6 TC-gasket 25/8 EPDM 28950948 61.81 USD Add to cart
Get Quote
7 TC clamp kit, 25 mm TC 28404336 245.00 USD Add to cart
Get Quote
7 TC Clamp kit TC25/SS 28404338 120.33 USD Add to cart
Get Quote

Troubleshooting

Find solutions to product related issues. For unlisted issues please contact local Cytiva service representation.

General advice to achieve good performance

Before packing or running the column please make sure that

  • the tubing, valves, gaskets etc. have the same inner diameter as the column in and outlets and tubing is not longer than needed.
  • the bed supports have a porosity appropriate for your chromatography medium.
  • the column has been correctly assembled, verified by passing a leakage test.
  • the chromatography medium and equipment are equilibrated in the packing buffer and to ambient temperature of packing environment.
  • that the pump is free from pulsations.
  • no pressure peaks appear.
  • that you have enough slurry volume, taken in account the compression factor of the medium.
  • packing is performed at optimal flow velocity.
  • the column meets pressure requirement for selected medium and packing procedure.

After completing the packing procedure please evaluate the efficiency of the column in terms of the height equivalent to a theoretical plate (HETP), reduced plate number (h) and the peak asymmetry factor (As).


Between batches it is recommended to perform cleaning-in-place (CIP) to remove precipitated material, strongly bound substances and other contaminants from the column bed without dismantling the column. Regular CIP is needed to ensure proper product quality and expected life time of medium and equipment.

Many issues that face chromatographers are common to all types of columns, while other issues are quite specific.
Select the appropriate equipment.

Drifting baseline

Worrying peak shape

Poor reproducibility

Column leakage

Strange peaks

Back pressure increases during operation

Unusual column appearance

Unusual column appearance

Poor product recovery

Poor packing evaluation result

On this troubleshooting site, we refer to leading and tailing peaks as defined according to the following figures.


Leading peak

Tailing peak

 
Experience shows that the best method of expressing the efficiency of a packed column is in terms of its height equivalent to a theoretical plate (HETP), reduced plate number (h) and its peak asymmetry factor (As).

Unsatisfactory elution

Contact