Figure 4. Stainless steel bed supports.

Please note:

Item numbers in gray illustrates parts in contact with process stream.

Item numbers are not necessarily in sequential order.

Important: AxiChrom stainless steel and plastic bed supports are not directly interexchangable.

Important: The 10 and 20 µm bed supports are not interexchangable. The entire bed support kit, that is the bottom plate and top assembly, must be exchanged.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
301 Bed support adaptor AxiChrom 70, 10 µm 28924574 1 379.00 USD Add to cart
Get Quote
301 Bed support 70 top/20SS 28963430 1 255.00 USD Add to cart
Get Quote
302 Bed support bottom AxiChrom 70, 10 µm 28401931 792.00 USD Add to cart
Get Quote
302 Bed support 70 bottom/20 SS 28963267 920.00 USD Add to cart
Get Quote
401 Screw M3x8 mm 28901470 36.74 USD Add to cart
Get Quote
403 Screw M3x16 mm 28901467 26.83 USD Add to cart
Get Quote
501 Adaptor plate AxiChrom 70, 20 µm Bed Support 28963433 1 421.00 USD Add to cart
Get Quote
501 Adaptor AxiChrom 70 10microm 28966770 1 442.00 USD Add to cart
Get Quote
502 Bottom plate AxiChrom 70, 20 µm Bed support 28963222 1 484.00 USD Add to cart
Get Quote
502 Bottom plate AxiChrom 70 10microm 28966779 1 517.00 USD Add to cart
Get Quote
603 O-ring 47x2 EPDM 28963418 131.55 USD Add to cart
Get Quote
604 Scraper and O-ring AxiChrom 70 28977257 350.00 USD Add to cart
Get Quote
606 O-ring 63.09x3.53 mm 28963261 95.01 USD Add to cart
Get Quote
607 O-ring 54x2 mm 28963254 210.00 USD Add to cart
Get Quote
Bed Support kit AxiChrom 70, 20 µm SS 28966446 2 060.00 USD Add to cart
Get Quote
Bed Support kit AxiChrom 70, 10 µm SS 28966448 2 288.00 USD Add to cart
Get Quote

Please note:

Item numbers in gray illustrates parts in contact with process stream.

Item numbers are not necessarily in sequential order.

Important: AxiChrom stainless steel and plastic bed supports are not directly interexchangable.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
101 Stop Plug 5/16" Male 18111250 30.19 USD Add to cart
Get Quote
102 O-ring 19.5x3 mm 28401919 27.77 USD Add to cart
Get Quote
104 O-ring 10.3x2.4 mm 28401783 20.50 USD Add to cart
Get Quote
105 Adaptor rod top 28401900 212.00 USD Add to cart
Get Quote
106 Set screw M3x6 28401790 44.00 USD Add to cart
Get Quote
107 Vent valve 28960875 87.44 USD Add to cart
Get Quote
108 O-ring 65x3 mm 28401920 27.82 USD Add to cart
Get Quote
109 Tube connection 5/16 id 2.9 Fem/fem 28963351 177.86 USD Add to cart
Get Quote
111 O-ring 14x1.5 mm 28401922 23.98 USD Add to cart
Get Quote
405 Tube i.d. 2.9 mm complete 28988333 396.00 USD Add to cart
Get Quote
602 O-ring 3x1 EPDM 28963214 31.44 USD Add to cart
Get Quote
802 Adaptor rod 28401817 679.00 USD Add to cart
Get Quote
803 Top plate 28978949 1 002.00 USD Add to cart
Get Quote

Figure 3. Stainless steel bed supports

Please note:

Item numbers in gray illustrates parts in contact with process stream.

Item numbers are not necessarily in sequential order.

Important: AxiChrom stainless steel and plastic bed supports are not directly interexchangable.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
101 Stop Plug 5/16" Male 18111250 30.19 USD Add to cart
Get Quote
102 O-ring 19.5x3 mm 28401919 27.77 USD Add to cart
Get Quote
104 O-ring 10.3x2.4 mm 28401783 20.50 USD Add to cart
Get Quote
105 Adaptor rod top 28401900 212.00 USD Add to cart
Get Quote
106 Set screw M3x6 28401790 44.00 USD Add to cart
Get Quote
107 Vent valve 28960875 87.44 USD Add to cart
Get Quote
108 O-ring 65x3 mm 28401920 27.82 USD Add to cart
Get Quote
109 Tube connection 5/16 id 2.9 Fem/fem 28963351 177.86 USD Add to cart
Get Quote
111 O-ring 14x1.5 mm 28401922 23.98 USD Add to cart
Get Quote
126 Vent valve 28960875 87.44 USD Add to cart
Get Quote
405 Tube i.d. 2.9 mm complete 28988333 396.00 USD Add to cart
Get Quote
602 O-ring 3x1 EPDM 28963214 31.44 USD Add to cart
Get Quote
802 Adaptor rod 28401817 679.00 USD Add to cart
Get Quote
803 Top plate 28978949 1 002.00 USD Add to cart
Get Quote

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Bayonet tool 28401390 91.72 USD Add to cart
Get Quote
2 Hook wrench key 28907141 119.72 USD Add to cart
Get Quote
3 Mounting aid for O-rings 28924749 13.55 USD Add to cart
Get Quote
4 Centering tool 28401903 283.00 USD Add to cart
Get Quote
5 Tool kit small AxiChrom 50–200 28936136 549.00 USD Add to cart
Get Quote
6 Tool Kit Complete for AxiChrom 50–200 Columns 28944261 1 637.00 USD Add to cart
Get Quote

Figure 4. Spare parts, Plastic bed supports.

Please note:

Item numbers in gray illustrates parts in contact with process stream.

Item numbers are not necessarily in sequential order.

Important: AxiChrom stainless steel and plastic bed supports are not directly interexchangable.

Important: The 10 and 20 µm bed supports are not interexchangable. The entire bed support kit, that is the bottom plate and top assembly, must be exchanged.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
301 Bed support 70 top/bottom 10mikrom UHMWPE 28988338 576.00 USD Add to cart
Get Quote
301 Bed support 70 top/bottom 20mikrom PE 28988341 579.00 USD Add to cart
Get Quote
401 Set screw M3x12.5 mm special 28988329 61.38 USD Add to cart
Get Quote
402 Distributor 70 top, PE bed support 28988344 847.00 USD Add to cart
Get Quote
403 Screw M3x16 mm 28901467 26.83 USD Add to cart
Get Quote
404 Distributor 70 bottom, PE bed support 28988345 872.00 USD Add to cart
Get Quote
409 O-ring 47x2 EPDM 28963418 131.55 USD Add to cart
Get Quote
412 Washer 3.2x9x0.8 mm 28988461 24.83 USD Add to cart
Get Quote
413 O-ring 2.5 x 1.3 EPDM 28988459 49.97 USD Add to cart
Get Quote
421 Snap ring 70 top/bottom, PE bed support 28988328 412.00 USD Add to cart
Get Quote
422 Support net 70, PE bed support 28988335 78.38 USD Add to cart
Get Quote
501 Adaptor plate 28988337 716.00 USD Add to cart
Get Quote
502 Bottom plate 70 28988343 729.00 USD Add to cart
Get Quote
604 Scraper and O-ring AxiChrom 70 28977257 350.00 USD Add to cart
Get Quote
606 O-ring 63.09x3.53 mm 28963261 95.01 USD Add to cart
Get Quote
Scraper and O-ring AxiChrom 70 28977257 350.00 USD Add to cart
Get Quote

Please note:

Item numbers in gray illustrates parts in contact with process stream.

Item numbers are not necessarily in sequential order.

Important: AxiChrom stainless steel and plastic bed supports are not directly interexchangable.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
101 Stop Plug 5/16" Male 18111250 30.19 USD Add to cart
Get Quote
114 O-ring 72x2 mm 28401914 29.23 USD Add to cart
Get Quote
115 Tube support 28901442 204.00 USD Add to cart
Get Quote
116 Check valve holder 28401767 251.00 USD Add to cart
Get Quote
117 Check valve 18110213 97.28 USD Add to cart
Get Quote
119 Washer M6 6.4x12x2 mm 28901462 21.27 USD Add to cart
Get Quote
201 Column tube 70/300 short 28963300 1 728.00 USD Add to cart
Get Quote
201 Column tube 70/500 long 28963303 2 081.00 USD Add to cart
Get Quote
804 Top bayonet 28978966 1 134.00 USD Add to cart
Get Quote
805 Bottom flange 28401798 582.00 USD Add to cart
Get Quote
806 Nut M6 18112648 32.79 USD Add to cart
Get Quote
901 Tie bar short 28401760 144.94 USD Add to cart
Get Quote
901 Tie bar long 28401796 156.80 USD Add to cart
Get Quote

Bed support kit 10 µm (28-9664-48) and related parts.

Important: The 10 and 20 µm bed supports are not interexchangable. The entire bed support kit, that is the bottom plate and top assembly, must be exchanged.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Bed Support kit AxiChrom 70, 10 µm SS 28966448 2 288.00 USD Add to cart
Get Quote
Bed support bottom AxiChrom 70, 10 µm 28401931 792.00 USD Add to cart
Get Quote
Screw M3x16 mm 28901467 26.83 USD Add to cart
Get Quote
O-ring 63.17x2.62 mm for piston scraper 28924572 169.24 USD Add to cart
Get Quote
Bed support adaptor AxiChrom 70, 10 µm 28924574 1 379.00 USD Add to cart
Get Quote
Adaptor AxiChrom 70 10microm 28966770 1 442.00 USD Add to cart
Get Quote
Bottom plate AxiChrom 70 10microm 28966779 1 517.00 USD Add to cart
Get Quote

Bed support kit 20 µm (28-9664-46) and related parts.

Important: The 10 and 20 µm bed supports are not interexchangable. The entire bed support kit, that is the bottom plate and top assembly, must be exchanged.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Bed Support kit AxiChrom 70, 20 µm SS 28966446 2 060.00 USD Add to cart
Get Quote
Screw M3x16 mm 28901467 26.83 USD Add to cart
Get Quote
O-ring 63.17x2.62 mm for piston scraper 28924572 169.24 USD Add to cart
Get Quote

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
131 Stop plug 5/16" 28981957 79.85 USD Add to cart
Get Quote
701 Pivot Stand for AxiChrom 50/70/100-300 28401709 1 613.00 USD Add to cart
Get Quote
701 Pivot stand for AxiChrom 50/70/100-500 28401710 1 662.00 USD Add to cart
Get Quote

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
801 Screw M4 x 16 18110956 53.65 USD Add to cart
Get Quote

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Adaptor tube id 2.9 L=636 28963326 149.67 USD Add to cart
Get Quote
3 Bed support adaptor AxiChrom 70, 10 µm 28924574 1 379.00 USD Add to cart
Get Quote
4 Bed support 70 top/20SS 28963430 1 255.00 USD Add to cart
Get Quote
5 Bed support bottom AxiChrom 70, 10 µm 28401931 792.00 USD Add to cart
Get Quote
6 Bed support 70 bottom/20 SS 28963267 920.00 USD Add to cart
Get Quote
7 O-ring 3x1 EPDM 28963214 31.44 USD Add to cart
Get Quote
8 O-ring 47x2 EPDM 28963418 131.55 USD Add to cart
Get Quote
9 Scraper and O-ring AxiChrom 70 28977257 350.00 USD Add to cart
Get Quote
10 Scraper and O-ring AxiChrom 70 28977257 350.00 USD Add to cart
Get Quote
11 O-ring 63.09x3.53 mm 28963261 95.01 USD Add to cart
Get Quote
12 O-ring 54x2 mm 28963254 210.00 USD Add to cart
Get Quote
13 Vent valve 28960875 87.44 USD Add to cart
Get Quote
14 Check valve 18110213 97.28 USD Add to cart
Get Quote

Accessories

Figure. Accessories for packing and running AxiChrom 70 and AxiChrom 100 with ÄKTApilot.

Please note:

Item numbers are not necessarily in sequential order.

Items 1, 2 and 4 are part of tubing kit.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 O-ring 3 x 1 mm 11002547 99.90 USD Add to cart
Get Quote
1 ÄKTApilot O-Ring, 3 × 1 mm 18116912 661.00 USD Add to cart
Get Quote
1 Tubing Kit for Connecting AxiChrom 70 and AxiChrom 100 on Floor to ÄKTApilot, i.d. 2.9 mm 28913614 392.00 USD Add to cart
Get Quote
5 Valve One Straight Channel, 5/16" 28907674 968.00 USD Add to cart
Get Quote
6 Vent valve 28960875 87.44 USD Add to cart
Get Quote
7 Stop Plug 5/16" Male 18111250 30.19 USD Add to cart
Get Quote
8 Pivot Stand for AxiChrom 50/70/100-300 28401709 1 613.00 USD Add to cart
Get Quote
9 Pivot stand for AxiChrom 50/70/100-500 28401710 1 662.00 USD Add to cart
Get Quote
10 AxiChrom foot 70 28401937 459.00 USD Add to cart
Get Quote
11 Mechanical Locking for AxiChrom 70 28401840 679.00 USD Add to cart
Get Quote
11 Mechanical Locking for AxiChrom 100 28401841 992.00 USD Add to cart
Get Quote
12 Tool kit small AxiChrom 50–200 28936136 549.00 USD Add to cart
Get Quote
12 Tool Kit Complete for AxiChrom 50–200 Columns 28944261 1 637.00 USD Add to cart
Get Quote
13 Union, M6 Female - 5/16" Male 18116916 105.47 USD Add to cart
Get Quote
13 Union, M6 Female - 5/16" Female 18116917 89.33 USD Add to cart
Get Quote
14 Connector, 5/16" Female - 5/16" Female 18117351 221.00 USD Add to cart
Get Quote
15 Connector 5/16" Female - M6 Male 18112776 55.00 USD Add to cart
Get Quote
16 Union 5/16" female - 1/16" male 18114208 47.45 USD Add to cart
Get Quote
17 Connector, 25 mm TC - UNF 5/16" Female 18116922 160.67 USD Add to cart
Get Quote
18 Connector, 25 mm TC - UNF 5/16" Male 18116923 164.99 USD Add to cart
Get Quote
19 TC-gasket kit 25 mm i.d. 6.5 mm 28966737 47.19 USD Add to cart
Get Quote
20 Clamp, 25 mm TC 28938190 120.54 USD Add to cart
Get Quote
21 Domed Nut, M6 18245001 47.45 USD Add to cart
Get Quote
22 Media Stirrer, 80 mm diameter 28919103 214.00 USD Add to cart
Get Quote
22 Media Stirrer, 40 mm diameter 28923180 383.00 USD Add to cart
Get Quote
23 Torque Wrench Kit for AxiChrom Columns 28936137 481.00 USD Add to cart
Get Quote
24 Torque Driver Kit for AxiChrom Columns 28936139 1 117.00 USD Add to cart
Get Quote

The illustrations show tubing connections for ÄKTA avant 150.

The illustration to the left refers to Tubing kit, AxiChrom 50 -70 / ÄKTA avant / desk, 28-9888-89.

The illustration to the right refers to Tubing kit, AxiChrom 50 - 70 / ÄKTA avant / floor, 28-9888-92.

Pos.

28-9888-89 Tubing kit, 

AxiChrom 50 - 70 / ÄKTA avant / desk

28-9888-92 Tubing kit, 

AxiChrom 50 - 70 / ÄKTA avant / floor

1 i.d. 1.7 / L=1200 (x2) i.d. 1.7 / L=1600 (x2)
2 i.d. 1.7 / L=800 (x1) i.d. 1.7 / L=1200 (x1)
3 i.d. 2.9 / L=1600 (x1) i.d. 2.9 / L=1600 (x1)
4 i.d. 1.7 / L=200 (x2) i.d. 1.7 / L=200 (x2)

 

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
Tubing kit AxiChrom 50-70 AKTA avant, desk 28988889 513.00 USD Add to cart
Get Quote
Tubing kit AxiChrom 50-70 AKTA avant, floor 28988892 519.00 USD Add to cart
Get Quote

Item Comment
1

Low Flow Kit, 28-9301-82 (for flow rates 3 l/h-175 l/h). 

2 Connector 25 mm TC- 5/16" female 18-1169-22. Two connectors needed to connect column to system.
3 TC Gasket 25 mm, i.d. 15 mm 44-5492-88. Two gaskets supplied with the flow kit. Two gaskets i.d. 15 mm needed to connect column to system.
4 TC Clamp 25 mm, 28-4043-38 (Stainless steel) or 28-4043-36 (Polypropylene).
5

For appropriate tubing i.d. refer to table below.

6 Stop Plug 5/16" male 18-1112-50.

To isolate the column from the system use Stop Plug 5/16" 28-9819-57.

 

Tubing

Column Tubing i.d. Tubing connection
AxiChrom 50 1.7 mm 5/16"
AxiChrom 70/100 2.9 mm 5/16"

 

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Connector, 25 mm TC - UNF 5/16" Female 18116922 160.67 USD Add to cart
Get Quote
3 TC-Gasket 25 mm i.d. 15 mm 44549288 169.54 USD Add to cart
Get Quote
4 TC clamp kit, 25 mm TC 28404336 245.00 USD Add to cart
Get Quote
4 TC Clamp kit TC25/SS 28404338 120.33 USD Add to cart
Get Quote
6 Stop Plug 5/16" Male 18111250 30.19 USD Add to cart
Get Quote
Stop plug 5/16" 28981957 79.85 USD Add to cart
Get Quote

Troubleshooting

Find solutions to product related issues. For unlisted issues please contact local Cytiva service representation.

Unsatisfactory elution

Poor packing evaluation result

On this troubleshooting site, we refer to leading and tailing peaks as defined according to the following figures.


Leading peak

Tailing peak

 
Experience shows that the best method of expressing the efficiency of a packed column is in terms of its height equivalent to a theoretical plate (HETP), reduced plate number (h) and its peak asymmetry factor (As).

Poor product recovery

Unusual column appearance

Unusual column appearance

Back pressure increases during operation

Strange peaks

Column leakage

Poor reproducibility

Worrying peak shape

Drifting baseline

General advice to achieve good performance

Before packing or running the column please make sure that

  • the tubing, valves, gaskets etc. have the same inner diameter as the column in and outlets and tubing is not longer than needed.
  • the bed supports have a porosity appropriate for your chromatography medium.
  • the column has been correctly assembled, verified by passing a leakage test.
  • the chromatography medium and equipment are equilibrated in the packing buffer and to ambient temperature of packing environment.
  • that the pump is free from pulsations.
  • no pressure peaks appear.
  • that you have enough slurry volume, taken in account the compression factor of the medium.
  • packing is performed at optimal flow velocity.
  • the column meets pressure requirement for selected medium and packing procedure.

After completing the packing procedure please evaluate the efficiency of the column in terms of the height equivalent to a theoretical plate (HETP), reduced plate number (h) and the peak asymmetry factor (As).


Between batches it is recommended to perform cleaning-in-place (CIP) to remove precipitated material, strongly bound substances and other contaminants from the column bed without dismantling the column. Regular CIP is needed to ensure proper product quality and expected life time of medium and equipment.

Many issues that face chromatographers are common to all types of columns, while other issues are quite specific.
Select the appropriate equipment.

Contact