FAQ

Accessories

Figure. BPG 100, Accessories for Running the column, parts identification.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Column Stand 100 Columns 18103110 1,231.00 USD Add to cart
2 Tubing, 300 mm, 25 mm TC, i.d. 6 mm 18000542 377.00 USD Add to cart
2 Tubing, 750 mm, 25 mm TC, i.d. 6 mm 18000543 403.00 USD Add to cart
2 Tubing, 1250 mm, 25 mm TC, i.d. 6 mm 18000544 409.00 USD Add to cart
2 Tubing, 1500 mm, 25 mm TC, i.d. 6 mm 18000545 423.00 USD Add to cart
2 Tubing, 2000 mm, 25 mm TC, i.d. 6 mm 18000547 474.00 USD Add to cart
2 Tubing with Sanitary Fittings, 50 cm, i.d. 6 mm, 25 mm TC 28405368 506.00 USD Add to cart
2 Tubing with Sanitary Fittings, 80 cm, i.d. 6 mm, 25 mm TC 28405369 531.00 USD Add to cart
2 Tubing with Sanitary Fittings, 1 m, i.d. 6 mm, 25 mm TC 28405370 535.00 USD Add to cart
2 Tubing with Sanitary Fittings, 2 m, i.d. 6 mm, 25 mm TC 28405371 681.00 USD Add to cart
2 Tubing with Sanitary Fittings, 4 m, i.d. 6 mm, 25 mm TC 28405372 827.00 USD Add to cart
3 Gasket 25 mm, i.d. 6 mm 18001927 18.97 USD Add to cart
3 Gaskets, 25 mm, i.d. 6 mm 18001928 59.02 USD Add to cart
3 TC-gasket 25/8 EPDM 28950948 76.07 USD Add to cart
4 TC Clamp kit TC25/SS 28404338 148.09 USD Add to cart
5 Valve 4-Port 2-Way ID 6 mm 18575701 2,084.00 USD Add to cart
6 Valve, 4-port, 4-way, i.d. 6 mm, 25 mm TC 18575801 2,092.00 USD Add to cart
7 Manometer Kit, 0-10 bar 18103107 3,367.00 USD Add to cart
8 Air Trap Complete 18110296 9,033.00 USD Add to cart
9 Safety Valve, 8 bar 18103580 3,583.00 USD Add to cart
10 T-Junction, 2 × 25 mm TC, i.d. 6 mm; 1 × 50 mm TC, i.d. 22 mm 28405765 988.00 USD Add to cart
11 Tubing with sanitary fittings, L=90 cm, i.d.19 mm, 51 mm TC 28404230 539.00 USD Add to cart
11 Tubing with sanitary fittings, L=200 cm, i.d.19 mm, 51 mm TC 28404232 4,088.00 USD Add to cart
11 Tubing with Sanitary Fittings, 400 cm, i.d.19 mm, 51 mm TC 28404233 1,525.00 USD Add to cart
11 Tubing with sanitary fittings, L=140 cm, i.d.19 mm, 51 mm TC 28404235 647.00 USD Add to cart
11 Tubing with Sanitary Fittings, 50 cm, i.d. 19.1 mm, 50 mm TC 28405379 2,315.00 USD Add to cart
11 Tubing with Sanitary Fittings, 80 cm, i.d. 19.1 mm, 50 mm TC 28405380 2,547.00 USD Add to cart
11 Tubing with Sanitary Fittings, 1 m, i.d. 19.1 mm, 50 mm TC 28405381 2,663.00 USD Add to cart
11 Tubing with Sanitary Fittings, 2 m, i.d. 19.1 mm, 50 mm TC 28405382 3,472.00 USD Add to cart
11 Tubing with Sanitary Fittings, 4 m, i.d. 19.1 mm, 50 mm TC 28405383 4,399.00 USD Add to cart
12 Gasket 51 mm 28966886 91.28 USD Add to cart
12 Gasket, 51 mm, i.d. 22 mm 44551203 102.54 USD Add to cart
13 Clamp, 50 mm TC, SS 44713401 11.38 USD Add to cart
14 Top Valve for Air Traps 18112144 1,633.00 USD Add to cart
16 Filter 215 nm 11000733 808.00 USD Add to cart
16 Filter 260 nm 11000734 781.00 USD Add to cart
16 Filter 280 nm 11000735 628.00 USD Add to cart
16 Filter 405 nm 11000736 760.00 USD Add to cart
16 Empty Filter Holder 11000738 248.00 USD Add to cart
16 Monitor UVis-920 Excluding Filter and Flow Cell 11000754 10,200.00 USD Add to cart
16 UV flow cell, i.d. 8 mm 28966687 3,723.00 USD Add to cart
16 O-ring kit 28969705 162.00 USD Add to cart
17 Flow cell, i.d. 6 mm, 25 mm TC 18100066 3,650.00 USD Add to cart
17 Filter Kit 280 nm 19243301 1,189.00 USD Add to cart
Torque Wrench for BPG Columns, 2-20 N 18025137 508.00 USD Add to cart
Allen Key for BPG Columns 18103098 36.22 USD Add to cart
12-Point Opening Socket for BPG 100 Column 18103103 91.08 USD Add to cart
Grounding kit 18115787 235.00 USD Add to cart

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Tubing, 1200 mm, i.d. 2.9 mm, o.d. 3/16", S8 18116975 248.00 USD Add to cart
2 Tubing, 400 mm, i.d. 2.9 mm, o.d. 3/16", S6 18116970 212.00 USD Add to cart
3 Connector, 25 mm TC - UNF 5/16" Female 18116922 191.48 USD Add to cart
4 TC Gasket, 25 mm, i.d. 4 mm 18116924 309.00 USD Add to cart

Figure. BPG 100, Accessories for Packing the column, parts identification.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Column Stand 100 Columns 18103110 1,231.00 USD Add to cart
2 Tubing, 300 mm, 25 mm TC, i.d. 6 mm 18000542 377.00 USD Add to cart
2 Tubing, 750 mm, 25 mm TC, i.d. 6 mm 18000543 403.00 USD Add to cart
2 Tubing, 1250 mm, 25 mm TC, i.d. 6 mm 18000544 409.00 USD Add to cart
2 Tubing, 1500 mm, 25 mm TC, i.d. 6 mm 18000545 423.00 USD Add to cart
2 Tubing, 2000 mm, 25 mm TC, i.d. 6 mm 18000547 474.00 USD Add to cart
2 Tubing with Sanitary Fittings, 50 cm, i.d. 6 mm, 25 mm TC 28405368 506.00 USD Add to cart
2 Tubing with Sanitary Fittings, 80 cm, i.d. 6 mm, 25 mm TC 28405369 531.00 USD Add to cart
2 Tubing with Sanitary Fittings, 1 m, i.d. 6 mm, 25 mm TC 28405370 535.00 USD Add to cart
2 Tubing with Sanitary Fittings, 2 m, i.d. 6 mm, 25 mm TC 28405371 681.00 USD Add to cart
2 Tubing with Sanitary Fittings, 4 m, i.d. 6 mm, 25 mm TC 28405372 827.00 USD Add to cart
3 Gasket 25 mm, i.d. 6 mm 18001927 18.97 USD Add to cart
3 Gaskets, 25 mm, i.d. 6 mm 18001928 59.02 USD Add to cart
3 TC-gasket 25/8 EPDM 28950948 76.07 USD Add to cart
4 TC Clamp kit TC25/SS 28404338 148.09 USD Add to cart
5 Valve 4-Port 2-Way ID 6 mm 18575701 2,084.00 USD Add to cart
6 Manometer Kit, 0-10 bar 18103107 3,367.00 USD Add to cart
7 Pressure Relief Valve for FineLINE 70,100, and 200 Columns 18110536 1,982.00 USD Add to cart
8 Safety Valve, 8 bar 18103580 3,583.00 USD Add to cart
9 T-Junction, 2 × 25 mm TC, i.d. 6 mm; 1 × 50 mm TC, i.d. 22 mm 28405765 988.00 USD Add to cart
10 Tubing with sanitary fittings, L=90 cm, i.d.19 mm, 51 mm TC 28404230 539.00 USD Add to cart
10 Tubing with sanitary fittings, L=200 cm, i.d.19 mm, 51 mm TC 28404232 4,088.00 USD Add to cart
10 Tubing with Sanitary Fittings, 400 cm, i.d.19 mm, 51 mm TC 28404233 1,525.00 USD Add to cart
10 Tubing with sanitary fittings, L=140 cm, i.d.19 mm, 51 mm TC 28404235 647.00 USD Add to cart
10 Tubing with Sanitary Fittings, 50 cm, i.d. 19.1 mm, 50 mm TC 28405379 2,315.00 USD Add to cart
10 Tubing with Sanitary Fittings, 80 cm, i.d. 19.1 mm, 50 mm TC 28405380 2,547.00 USD Add to cart
10 Tubing with Sanitary Fittings, 1 m, i.d. 19.1 mm, 50 mm TC 28405381 2,663.00 USD Add to cart
10 Tubing with Sanitary Fittings, 2 m, i.d. 19.1 mm, 50 mm TC 28405382 3,472.00 USD Add to cart
10 Tubing with Sanitary Fittings, 4 m, i.d. 19.1 mm, 50 mm TC 28405383 4,399.00 USD Add to cart
11 Gasket 51 mm 28966886 91.28 USD Add to cart
11 Gasket, 51 mm, i.d. 22 mm 44551203 102.54 USD Add to cart
12 Clamp, 50 mm TC, SS 44713401 11.38 USD Add to cart
13 Packing Device, BPG 100 Column 18110475 4,438.00 USD Add to cart
Torque Wrench for BPG Columns, 2-20 N 18025137 508.00 USD Add to cart
Blind Flange, including gasket, 25 mm 18100125 82.80 USD Add to cart
Allen Key for BPG Columns 18103098 36.22 USD Add to cart
12-Point Opening Socket for BPG 100 Column 18103103 91.08 USD Add to cart
Media Stirrer, 80 mm diameter 28919103 255.00 USD Add to cart

Item Comment
1

For flow rates 3 l/h-175 l/h use Low Flow Kit 28-9301-82.

For flow rates 7.5 l/h-510 l/h use High Flow Kit 28-9301-83.

2 For Low Flow Kit use tubing with i.d. 6 mm and for High Flow Kit use tubing with i.d. 9.5 mm (PTFE) or 10 mm (PVC), refer to tables below.
3 TC Gasket 25 mm i.d. 15 mm 44-5492-88, two gaskets are supplied with the flow kit. Two gaskets i.d. 15 mm are needed to connect column to system.
4 TC Clamp 25 mm 28-4043-38 (Stainless steel) or 44-4043-36 (Polypropylene).
5

For Low Flow Kit use 4-port, 2-way Valve, i.d. 6 mm, 25 mm TC 18-5757-01.

For High Flow Kit use 4-port, 2-way Valve i.d. 10 mm, 25 mm TC 18-1012-56.

6

For Low Flow Kit use gasket with i.d. 6 mm 18-0019-27 or i.d. 8 mm 28-9509-48.

For High Flow Kit use gasket with i.d. 10 mm 18-1035-79.

To isolate the column from the system use 4-port, 2-way valves or alternatively only  TC End Cap, 25 mm TC incl. gaskets 18-1001-25  and TC Clamp 25 mm.

 

PTFE tubing with 25 mm TC

Inner Diameter Length Code Number
6 mm 0.5 m 28-4053-68
6 mm 0.8 m 28-4053-69
6 mm 1 m 28-4053-70
6 mm 2 m 28-4053-71
6 mm 4 m 28-4053-72
9.5 mm 0.5 m 28-4053-73
9.5 mm 0.8 m 28-4053-75
9.5 mm 1 m 28-4053-76
9.5 mm 2 m 28-4053-77
9.5 mm 4 m 28-4053-78

 

PVC tubing with 25 mm TC

Inner Diameter Length Code Number
6 mm 0.3 m 18-0005-42
6 mm 0.75 m 18-0005-43
6 mm 1.25 m 18-0005-44
6 mm 1.5 m 18-0005-45
6 mm 2 m 18-0005-47
10 mm 0.3 m 18-1012-85
10 mm 0.4 m 18-1012-86
10 mm 0.9 m 18-1012-62
10 mm 1.4 m 18-1012-63
10 mm 1.7 m 18-1012-64
10 mm 2 m 18-1012-87

 

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Tubing, 300 mm, 25 mm TC, i.d. 6 mm 18000542 377.00 USD Add to cart
2 Tubing, 750 mm, 25 mm TC, i.d. 6 mm 18000543 403.00 USD Add to cart
2 Tubing, 1250 mm, 25 mm TC, i.d. 6 mm 18000544 409.00 USD Add to cart
2 Tubing, 1500 mm, 25 mm TC, i.d. 6 mm 18000545 423.00 USD Add to cart
2 Tubing, 2000 mm, 25 mm TC, i.d. 6 mm 18000547 474.00 USD Add to cart
2 Tubing, 900 mm, 25 mm TC, i.d.10 mm 18101262 393.00 USD Add to cart
2 Tubing, 1400 mm, 25 mm TC, i.d.10 mm 18101263 413.00 USD Add to cart
2 Tubing, 1700 mm, 25 mm TC, i.d. 10 mm 18101264 441.00 USD Add to cart
2 Tubing, 300 mm, 25 mm TC, i.d. 10 mm 18101285 372.00 USD Add to cart
2 Tubing, 400 mm, 25 mm TC i.d. 10 mm 18101286 381.00 USD Add to cart
2 Tubing, 2000 mm, 25 mm TC, i.d. 10 mm 18101287 507.00 USD Add to cart
2 Tubing with Sanitary Fittings, 50 cm, i.d. 6 mm, 25 mm TC 28405368 506.00 USD Add to cart
2 Tubing with Sanitary Fittings, 80 cm, i.d. 6 mm, 25 mm TC 28405369 531.00 USD Add to cart
2 Tubing with Sanitary Fittings, 1 m, i.d. 6 mm, 25 mm TC 28405370 535.00 USD Add to cart
2 Tubing with Sanitary Fittings, 2 m, i.d. 6 mm, 25 mm TC 28405371 681.00 USD Add to cart
2 Tubing with Sanitary Fittings, 4 m, i.d. 6 mm, 25 mm TC 28405372 827.00 USD Add to cart
2 Tubing with Sanitary Fittings, 50 cm, i.d. 9.5 mm, 25 mm TC 28405373 514.00 USD Add to cart
2 Tubing with Sanitary Fittings, 80 cm, i.d. 9.5 mm, 25 mm TC 28405375 573.00 USD Add to cart
2 Tubing with Sanitary Fittings, 1 m, i.d. 9.5 mm, 25 mm TC 28405376 578.00 USD Add to cart
2 Tubing with Sanitary Fittings, 2 m, i.d. 9.5 mm, 25 mm TC 28405377 774.00 USD Add to cart
2 Tubing with Sanitary Fittings, 4 m, i.d. 9.5 mm, 25 mm TC 28405378 1,018.00 USD Add to cart
3 TC-Gasket 25 mm i.d. 15 mm 44549288 209.00 USD Add to cart
4 TC clamp kit, 25 mm TC 28404336 302.00 USD Add to cart
4 TC Clamp kit TC25/SS 28404338 148.09 USD Add to cart
5 Valve 4-port, 2-way ID 10 18101256 2,125.00 USD Add to cart
5 Valve 4-Port 2-Way ID 6 mm 18575701 2,084.00 USD Add to cart
6 Gasket 25 mm, i.d. 6 mm 18001927 18.97 USD Add to cart
6 TC-Gasket 25 mm i.d. 10 mm 18103579 34.15 USD Add to cart
6 TC-gasket 25/8 EPDM 28950948 76.07 USD Add to cart
Blind Flange, including gasket, 25 mm 18100125 82.80 USD Add to cart

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 FEP Tubing, i.d. 1/8 in (3/16 in) 18111247 107.23 USD Add to cart
4 Connector, 25 mm TC i.d. 6 mm - M6 Female 18103109 127.30 USD Add to cart
4 Connector M6 Female - 25 mm TC, 6 mm, i.d. 1.9 mm 28405764 1,152.00 USD Add to cart
5 Fingertight Union 1/16" Male/M6 Female 18111258 135.19 USD Add to cart
6 Gasket 25 mm, i.d. 6 mm 18001927 18.97 USD Add to cart
7 Gaskets, 25 mm, i.d. 6 mm 18001928 59.02 USD Add to cart
8 TC-gasket 25/8 EPDM 28950948 76.07 USD Add to cart
9 TC Clamp kit TC25/SS 28404338 148.09 USD Add to cart

Spare parts

Fig 1. BPG 100, column parts identification.

 

Item numbers are not necessarily in sequential order. For parts shown in the figure but not listed below, please contact your sales or service representative.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Column Tube BPG 100/750 29208721 2,042.00 USD Add to cart
1 Column Tube BPG 100/950 29208722 2,555.00 USD Add to cart
2 Tie Rod BPG 100/500 18110580 128.68 USD Add to cart
2 Tie Rod BPG 100/750 18110581 150.76 USD Add to cart
2 Tie Rod BPG 100/950 18110582 120.03 USD Add to cart
3 Guide ring BPG 100 18025122 177.51 USD Add to cart
4 Net, 10 μm, end-piece 100 column PA 18025177 352.00 USD Add to cart
4 Net, 54 μm, end-piece BPG 100 18112697 2,342.00 USD Add to cart
4 Net, 12 μm, end-piece BPG 100 PEEK 18114838 359.00 USD Add to cart
4 Net, 23 μm, end-piece 100 column PP 18925201 331.00 USD Add to cart
5 Support net, end-piece 100 column 18025155 48.23 USD Add to cart
6 O-Ring 104.5 X 3.0 FEP 18001941 403.00 USD Add to cart
6 O-Ring 104.5 X 3.0 EPDM 18849401 28.06 USD Add to cart
8 Nut, M6 19158201 45.52 USD Add to cart
9 Washer BPG 100 18114326 75.92 USD Add to cart
12 End-piece BPG 100 18114418 1,181.00 USD Add to cart
13 Screw M6 x 12 18112647 42.28 USD Add to cart
14 Washer BPG 100 18114326 75.92 USD Add to cart
15 Column Stand 100 Columns 18103110 1,231.00 USD Add to cart
16 TC Clamp 25mm SS 18100131 47.13 USD Add to cart
37 Gasket 25 mm, i.d. 6 mm 18001927 18.97 USD Add to cart
37 TC-gasket 25/8 EPDM 28950948 76.07 USD Add to cart
38 Adjustable Foot 18112693 53.55 USD Add to cart
40 Valve 4-Port 2-Way ID 6 mm 18575701 2,084.00 USD Add to cart

Fig 2. BPG 100, column parts identification.

Item numbers are not necessarily in sequential order. For parts shown in the figure but not listed below, please contact your sales or service representative.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
14 Washer BPG 100 18114326 75.92 USD Add to cart
16 TC Clamp 25mm SS 18100131 47.13 USD Add to cart
17 Adjusting Knob BPG 100-140-200 18110927 1,291.00 USD Add to cart
18 Domed nuts BPG 100 18114325 79.05 USD Add to cart
19 Flange Nut BPG 100 29270784 675.00 USD Add to cart
20 Bushing ring BPG 100 18026401 119.73 USD Add to cart
21 Top plate BPG 100 18114324 587.00 USD Add to cart
22 Adjuster nut BPG 100 18025120 1,329.00 USD Add to cart
23 Allen screw, M8 x 45 19637501 72.05 USD Add to cart
24 Allen screw, M4 x 14 19635601 94.59 USD Add to cart
26 Adaptor head screw 18845701 179.17 USD Add to cart
27 Sealing Unit BPG 100 18114747 633.00 USD Add to cart
28 O-Ring Adaptor 88.3x5.3 FEP 18001940 444.00 USD Add to cart
28 O-Ring Adaptor 85.09x5.33 EPDM 18847501 36.83 USD Add to cart
30 Inner Adaptor Tube BPG 100-140-200 18111323 304.00 USD Add to cart
31 Outer Adaptor Tube BPG 100, 140, 200 18113483 2,083.00 USD Add to cart
34 Adaptor Plate BPG 100 18111280 1,170.00 USD Add to cart
35 Support net, adaptor 100 column 18110304 46.25 USD Add to cart
36 Net, 10 μm adaptor BPG 100 PA 18110305 305.00 USD Add to cart
36 Net, 23 μm adaptor BPG 100 PP 18110308 226.00 USD Add to cart
36 Net, 54 μm adaptor BPG 100 PP 18112696 845.00 USD Add to cart
36 Net, 12 μm adaptor BPG 100 PEEK 18114837 434.00 USD Add to cart
37 TC-gasket 25/8 EPDM 28950948 76.07 USD Add to cart
43 Support Washer BPG Columns 18114280 108.70 USD Add to cart
52 Plastic Washer BPG 100 18114279 77.58 USD Add to cart

O-rings and nets should be checked regularly for wear. Worn O-rings may not seal properly and over-used nets can affect distribution. Inspect the O-rings and evaluate the height equivalent to a theoretical plate (HETP) and peak asymmetry factor (As) to prevent poor performance due to old nets.

We recommend you to change the nets and O-rings when needed or at least annually. Please keep a set of each on your site, for code numbers refer to the table below.  

The column is delivered with O-rings in Ethylene propylene diene (EPDM). Ethylene propylene diene change characteristics when exposed to some organic chemicals. For repetitive long term use, use Fluoroethenepropene (FEP) polymers.

23 µm nets are supplied with the column and recommended for beads with an average particle diameter between 70-150 µm. For an average particle diameter < 70 µm use 10 µm or 12 µm nets and for an average particle diameter > 150 µm use 54 µm nets.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 O-Ring 104.5 X 3.0 EPDM 18849401 28.06 USD Add to cart
2 O-Ring 104.5 X 3.0 FEP 18001941 403.00 USD Add to cart
3 O-Ring Adaptor 85.09x5.33 EPDM 18847501 36.83 USD Add to cart
4 O-Ring Adaptor 88.3x5.3 FEP 18001940 444.00 USD Add to cart
5 Support net, adaptor 100 column 18110304 46.25 USD Add to cart
6 Support net, end-piece 100 column 18025155 48.23 USD Add to cart
7 Net, 10 μm adaptor BPG 100 PA 18110305 305.00 USD Add to cart
8 Net, 10 μm, end-piece 100 column PA 18025177 352.00 USD Add to cart
9 Net, 12 μm adaptor BPG 100 PEEK 18114837 434.00 USD Add to cart
10 Net, 12 μm, end-piece BPG 100 PEEK 18114838 359.00 USD Add to cart
11 Net, 23 μm adaptor BPG 100 PP 18110308 226.00 USD Add to cart
12 Net, 23 μm, end-piece 100 column PP 18925201 331.00 USD Add to cart
13 Net, 54 μm adaptor BPG 100 PP 18112696 845.00 USD Add to cart
14 Net, 54 μm, end-piece BPG 100 18112697 2,342.00 USD Add to cart
15 Guide ring BPG 100 18025122 177.51 USD Add to cart

Troubleshooting

Find solutions to product related issues. For unlisted issues please contact local Cytiva service representation.

General advice to achieve good performance

Before packing or running the column please make sure that

  • the tubing, valves, gaskets etc. have the same inner diameter as the column in and outlets and tubing is not longer than needed.
  • the bed supports have a porosity appropriate for your chromatography medium.
  • the column has been correctly assembled, verified by passing a leakage test.
  • the chromatography medium and equipment are equilibrated in the packing buffer and to ambient temperature of packing environment.
  • that the pump is free from pulsations.
  • no pressure peaks appear.
  • that you have enough slurry volume, taken in account the compression factor of the medium.
  • packing is performed at optimal flow velocity.
  • the column meets pressure requirement for selected medium and packing procedure.

After completing the packing procedure please evaluate the efficiency of the column in terms of the height equivalent to a theoretical plate (HETP), reduced plate number (h) and the peak asymmetry factor (As).


Between batches it is recommended to perform cleaning-in-place (CIP) to remove precipitated material, strongly bound substances and other contaminants from the column bed without dismantling the column. Regular CIP is needed to ensure proper product quality and expected life time of medium and equipment.

Many issues that face chromatographers are common to all types of columns, while other issues are quite specific.
Select the appropriate equipment.

Worrying peak shape

Strange peaks

Column leakage

Poor reproducibility

Back pressure increases during operation

Unusual column appearance

Poor product recovery

Drifting baseline

Poor packing evaluation result

On this troubleshooting site, we refer to leading and tailing peaks as defined according to the following figures.


Leading peak

Tailing peak

 
Experience shows that the best method of expressing the efficiency of a packed column is in terms of its height equivalent to a theoretical plate (HETP), reduced plate number (h) and its peak asymmetry factor (As).

Unsatisfactory elution

Contact