FAQ

Spare parts

Item numbers with a white background are not available as standard spare parts.

Please note that item numbers are not necessarily in sequential order.

Tools are not present in the figure.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
7 Tool, Bed support retaining nut 18116110 1,683.00 USD Add to cart
8 Mounting Tool, Nozzle tip seal 18116175 293.00 USD Add to cart
12 Locking rod, Chromaflow 400-800, M20 18116251 426.00 USD Add to cart
13 Locking rod nut, M20 18116414 58.77 USD Add to cart
14 Bed support bottom Chromaflow 400, 10 µm complete 28942688 16,100.00 USD Add to cart
15 Bed support adaptor Chromaflow 400, 10 µm complete 28942691 15,800.00 USD Add to cart
16 Bed support bottom Chromaflow 400, 20 µm complete 28942694 15,400.00 USD Add to cart
17 Bed support adaptor Chromaflow 400, 20 µm complete 28942695 15,400.00 USD Add to cart
20 Column tube 400/100-300 18116076 26,500.00 USD Add to cart
20 Column tube 400/200-400 18116077 29,600.00 USD Add to cart
20 Column tube 400/300-500 18116078 32,700.00 USD Add to cart

Item numbers with a white background are not available as standard spare parts.

Please note that item numbers are not necessarily in sequential order.

Tools are not present in the figure.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Seal kit, nozzle man/auto 18116104 552.00 USD Add to cart
2 Nozzle tip, with O-rings mounted 18116106 1,392.00 USD Add to cart
7 Tool, Bed support retaining nut 18116110 1,683.00 USD Add to cart
8 Mounting Tool, Nozzle tip seal 18116175 293.00 USD Add to cart

O-rings should be checked regularly for wear and replaced when needed or at least annually. Worn O-rings may not seal properly. We recommend you to keep a set of nozzle seals and column seals on your site, for code no refer to table below.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Seal kit, nozzle man/auto 18116104 552.00 USD Add to cart
3 Nozzle tip, with O-rings mounted 18116106 1,392.00 USD Add to cart
4 Bed support retaining nut 18116107 661.00 USD Add to cart
5 Flushing kit sanitary barrier, flushing tube unit 18116108 821.00 USD Add to cart

Item numbers with a white background are not available as standard spare parts.

Please note that item numbers are not necessarily in sequential order.

Tools are not present in the figure.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
3 Bed support retaining nut 18116107 661.00 USD Add to cart
4 Flushing kit sanitary barrier, flushing tube unit 18116108 821.00 USD Add to cart
5 Clamp nut, insert M20 18116109 917.00 USD Add to cart
7 Tool, Bed support retaining nut 18116110 1,683.00 USD Add to cart
8 Mounting Tool, Nozzle tip seal 18116175 293.00 USD Add to cart

Accessories

Figure. Running Chromaflow 400 Columns.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Tubing, 900 mm, 25 mm TC, i.d.10 mm 18101262 393.00 USD Add to cart
1 Tubing, 1400 mm, 25 mm TC, i.d.10 mm 18101263 413.00 USD Add to cart
1 Tubing, 1700 mm, 25 mm TC, i.d. 10 mm 18101264 441.00 USD Add to cart
1 Tubing, 2000 mm, 25 mm TC, i.d. 10 mm 18101287 507.00 USD Add to cart
1 Tubing, 750 mm, 25 mm TC, i.d. 14 mm 18102728 425.00 USD Add to cart
1 Tubing, 1800 mm, 25 mm TC, i.d. 14 mm 18102729 535.00 USD Add to cart
1 Tubing with Sanitary Fittings, 50 cm, i.d. 9.5 mm, 25 mm TC 28405373 514.00 USD Add to cart
1 Tubing with Sanitary Fittings, 80 cm, i.d. 9.5 mm, 25 mm TC 28405375 573.00 USD Add to cart
1 Tubing with Sanitary Fittings, 1 m, i.d. 9.5 mm, 25 mm TC 28405376 578.00 USD Add to cart
1 Tubing with Sanitary Fittings, 2 m, i.d. 9.5 mm, 25 mm TC 28405377 774.00 USD Add to cart
1 Tubing with Sanitary Fittings, 4 m, i.d. 9.5 mm, 25 mm TC 28405378 1,018.00 USD Add to cart
2 Tubing with sanitary fittings, L=90 cm, i.d.19 mm, 51 mm TC 28404230 539.00 USD Add to cart
2 Tubing with sanitary fittings, L=200 cm, i.d.19 mm, 51 mm TC 28404232 4,088.00 USD Add to cart
2 Tubing with Sanitary Fittings, 400 cm, i.d.19 mm, 51 mm TC 28404233 1,525.00 USD Add to cart
2 Tubing with sanitary fittings, L=140 cm, i.d.19 mm, 51 mm TC 28404235 647.00 USD Add to cart
2 Tubing with Sanitary Fittings, 50 cm, i.d. 19.1 mm, 50 mm TC 28405379 2,315.00 USD Add to cart
2 Tubing with Sanitary Fittings, 80 cm, i.d. 19.1 mm, 50 mm TC 28405380 2,547.00 USD Add to cart
2 Tubing with Sanitary Fittings, 1 m, i.d. 19.1 mm, 50 mm TC 28405381 2,663.00 USD Add to cart
2 Tubing with Sanitary Fittings, 2 m, i.d. 19.1 mm, 50 mm TC 28405382 3,472.00 USD Add to cart
2 Tubing with Sanitary Fittings, 4 m, i.d. 19.1 mm, 50 mm TC 28405383 4,399.00 USD Add to cart
4 Gasket, 25 mm, i.d. 10 mm 18101240 113.99 USD Add to cart
4 TC-Gasket 25 mm i.d. 10 mm 18103579 34.15 USD Add to cart
5 Gasket 51 mm 28966886 91.28 USD Add to cart
5 Gasket, 51 mm, i.d. 22 mm 44551203 102.54 USD Add to cart
7 TC Clamp 25mm SS 18100131 47.13 USD Add to cart
7 Clamps 25 mm 44056801 191.20 USD Add to cart
8 Clamp, 50 mm TC, SS 44713401 11.38 USD Add to cart
9 Valve 2-way, 3-port, i.d. 22 mm, 51 mm TC 44158301 2,568.00 USD Add to cart
10 Blind Flange, 51 mm TC 44713501 109.71 USD Add to cart
11 Pressure sensor i.d. 22 mm, 51 mm TC 28934324 5,687.00 USD Add to cart
12 Safety valve, 3 bar, 51 mm TC 18573801 3,803.00 USD Add to cart
14 Castors assembly kit 18117151 4,834.00 USD Add to cart
15 Nozzle Piping, Chromaflow 400, i.d. 1", 51 mm TC 18117199 3,694.00 USD Add to cart
15 Nozzle Piping, Chromaflow 400, i.d. 3/4", 51 mm TC 18117200 3,304.00 USD Add to cart
15 Nozzle Piping, Chromaflow 400, i.d. 1/2", 51 mm TC 18117201 3,304.00 USD Add to cart

Figure. Accessories, Packing and unpacking the Chromafow 400 Columns with a packing station.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Tubing, 900 mm, 25 mm TC, i.d.10 mm 18101262 393.00 USD Add to cart
2 Tubing, 1400 mm, 25 mm TC, i.d.10 mm 18101263 413.00 USD Add to cart
2 Tubing, 1700 mm, 25 mm TC, i.d. 10 mm 18101264 441.00 USD Add to cart
2 Tubing, 2000 mm, 25 mm TC, i.d. 10 mm 18101287 507.00 USD Add to cart
2 Tubing, 750 mm, 25 mm TC, i.d. 14 mm 18102728 425.00 USD Add to cart
2 Tubing, 1800 mm, 25 mm TC, i.d. 14 mm 18102729 535.00 USD Add to cart
2 Tubing with Sanitary Fittings, 50 cm, i.d. 9.5 mm, 25 mm TC 28405373 514.00 USD Add to cart
2 Tubing with Sanitary Fittings, 80 cm, i.d. 9.5 mm, 25 mm TC 28405375 573.00 USD Add to cart
2 Tubing with Sanitary Fittings, 1 m, i.d. 9.5 mm, 25 mm TC 28405376 578.00 USD Add to cart
2 Tubing with Sanitary Fittings, 2 m, i.d. 9.5 mm, 25 mm TC 28405377 774.00 USD Add to cart
2 Tubing with Sanitary Fittings, 4 m, i.d. 9.5 mm, 25 mm TC 28405378 1,018.00 USD Add to cart
3 Tubing with sanitary fittings, L=90 cm, i.d.19 mm, 51 mm TC 28404230 539.00 USD Add to cart
3 Tubing with sanitary fittings, L=200 cm, i.d.19 mm, 51 mm TC 28404232 4,088.00 USD Add to cart
3 Tubing with Sanitary Fittings, 400 cm, i.d.19 mm, 51 mm TC 28404233 1,525.00 USD Add to cart
3 Tubing with sanitary fittings, L=140 cm, i.d.19 mm, 51 mm TC 28404235 647.00 USD Add to cart
3 Tubing with Sanitary Fittings, 50 cm, i.d. 19.1 mm, 50 mm TC 28405379 2,315.00 USD Add to cart
3 Tubing with Sanitary Fittings, 80 cm, i.d. 19.1 mm, 50 mm TC 28405380 2,547.00 USD Add to cart
3 Tubing with Sanitary Fittings, 1 m, i.d. 19.1 mm, 50 mm TC 28405381 2,663.00 USD Add to cart
3 Tubing with Sanitary Fittings, 2 m, i.d. 19.1 mm, 50 mm TC 28405382 3,472.00 USD Add to cart
3 Tubing with Sanitary Fittings, 4 m, i.d. 19.1 mm, 50 mm TC 28405383 4,399.00 USD Add to cart
5 Gasket, 25 mm, i.d. 10 mm 18101240 113.99 USD Add to cart
5 TC-Gasket 25 mm i.d. 10 mm 18103579 34.15 USD Add to cart
6 Gasket 51 mm 28966886 91.28 USD Add to cart
6 Gasket, 51 mm, i.d. 22 mm 44551203 102.54 USD Add to cart
7 Gaskets i.d. 35 mm 44051501 97.88 USD Add to cart
8 TC Clamp 25mm SS 18100131 47.13 USD Add to cart
8 Clamps 25 mm 44056801 191.20 USD Add to cart
9 Clamp, 50 mm TC, SS 44713401 11.38 USD Add to cart
10 Valve 2-way, 3-port, i.d. 22 mm, 51 mm TC 44158301 2,568.00 USD Add to cart
11 Pressure sensor i.d. 22 mm, 51 mm TC 28934324 5,687.00 USD Add to cart
12 Safety valve, 3 bar, 51 mm TC 18573801 3,803.00 USD Add to cart
14 Castors assembly kit 18117151 4,834.00 USD Add to cart
15 Nozzle Piping, Chromaflow 400, i.d. 1", 51 mm TC 18117199 3,694.00 USD Add to cart
15 Nozzle Piping, Chromaflow 400, i.d. 3/4", 51 mm TC 18117200 3,304.00 USD Add to cart
15 Nozzle Piping, Chromaflow 400, i.d. 1/2", 51 mm TC 18117201 3,304.00 USD Add to cart

Troubleshooting

Find solutions to product related issues. For unlisted issues please contact local Cytiva service representation.

General advice to achieve good performance

Before packing or running the column please make sure that

  • the tubing, valves, gaskets etc. have the same inner diameter as the column in and outlets and tubing is not longer than needed.
  • the bed supports have a porosity appropriate for your chromatography medium.
  • the column has been correctly assembled, verified by passing a leakage test.
  • the chromatography medium and equipment are equilibrated in the packing buffer and to ambient temperature of packing environment.
  • that the pump is free from pulsations.
  • no pressure peaks appear.
  • that you have enough slurry volume, taken in account the compression factor of the medium.
  • packing is performed at optimal flow velocity.
  • the column meets pressure requirement for selected medium and packing procedure.

After completing the packing procedure please evaluate the efficiency of the column in terms of the height equivalent to a theoretical plate (HETP), reduced plate number (h) and the peak asymmetry factor (As).


Between batches it is recommended to perform cleaning-in-place (CIP) to remove precipitated material, strongly bound substances and other contaminants from the column bed without dismantling the column. Regular CIP is needed to ensure proper product quality and expected life time of medium and equipment.

Many issues that face chromatographers are common to all types of columns, while other issues are quite specific.
Select the appropriate equipment.

Worrying peak shape

Column leakage

Strange peaks

Poor reproducibility

Unusual column appearance

Poor product recovery

Drifting baseline