FAQ

Accessories

When running FlexStand Holder with peristaltic pump, the maximum pressure that can be achieved is 2 bar g (30 psi g).

The use of a permeate flow control is strongly recommended during upstream clarification of target material. 

A permeate flow control kit together with a pump for the flow rate is required for permeate flow control. Permeate flow control rate is dependent on the process flux (LMH) and surface area. 

Detailed information about the Permeate flow control kit (56-4107-73) and peristaltic pump, flow rates 5.4 ml/min - 2 liter/min (56-4106-53), is available below. 

Feed pump (11-0005-66 or 11-0005-67), Feed reservoir (56-4107-67 or 56-4107-70), Outlet pressure gauge for FS-03LVS (56-4106-04), Outlet pressure gauge for FS-03LVS-30 ( 56-4106-03) and Tubing (56-4106-19, 56-4105-22 or 56-4106-23) have to be ordered separately. Detailed information about these products is available below.

Details regarding the Low void volume assembly kit (56-4107-62) are also available below.

For countries using 220 V power, power cords have to be ordered separately for the feed and permeate flow control pumps.

After use, store the cartridge with liquid inside using blank off cap, gasket and clamp on the feed and retentate ports.

Seal the permeate port with a short piece of tubing i.d. 13 mm, which is secured using snapper clamp or cable tie wrap. The end is closed with pinch clamp, snapper clamp or cable tie wrap.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Gasket 50 mm (1.5") TC i.d. 38 mm, silicone 56410996 88.79 USD Add to cart
Get Quote
3 Clamp 50 mm (1.5") TC (Toggle Clamp) 56410669 75.77 USD Add to cart
Get Quote
4 Peristaltic Tubing, size 82, 7.6 m, i.d. 13 mm, bioprene 56410622 570.00 USD Add to cart
Get Quote
4 Peristaltic Tubing, size 82, 7.6 m, i.d. 13 mm, silicone 56410623 607.00 USD Add to cart
Get Quote
6 Tubing Connector Kit for FlexStand Standard System 56410764 770.00 USD Add to cart
Get Quote
Pressure Gauge 0-2 barg (0-30 psig) 50 mm (1.5") TC, back mount, autoclavable 56410603 964.00 USD Add to cart
Get Quote
Pressure Gauge 0-4 barg (0-60 psig) 50 mm (1.5") TC, back mount, autoclavable 56410604 964.00 USD Add to cart
Get Quote
Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 165.75 USD Add to cart
Get Quote
Peristaltic Pump Dual Voltage 56410653 2 658.00 USD Add to cart
Get Quote
Clamp 50 mm TC 56410667 113.65 USD Add to cart
Get Quote
Clamp 50 mm TC 56410668 75.77 USD Add to cart
Get Quote
Clamp 64 mm (2") TC 56410670 85.24 USD Add to cart
Get Quote
Manual Permeate Control Kit, includes vacuum/pressure gauge, backpressure valve, supports, adapters, clamps, and gaskets 56410773 2 147.00 USD Add to cart
Get Quote
50 mm (1.5") TC Blank-Off Cap, polysulfone 56410990 86.43 USD Add to cart
Get Quote
Gasket 64 mm (2") TC i.d. 50 mm, silicone 56410998 105.37 USD Add to cart
Get Quote

The use of a permeate flow control is strongly recommended during upstream clarification of target material. 

A permeate flow control kit together with a pump for the flow rate is required for permeate flow control. Permeate flow control rate is dependent on the process flux (LMH) and surface area. Detailed information about the Permeate flow control kit (56-4107-73) and peristaltic pump, flow rates 5.4 ml/min - 2 liter/min (56-4106-53), is available below. 

Feed reservoir (56-4107-67 or 56-4107-70) has to be ordered separately. Detailed information can be found below.

Details regarding the Low void volume assembly kit (56-4107-62) are also available below.

Countries using 220 V power, have to order power cords separately for the pump above and system.

After use, store the cartridge with liquid inside using blank off cap, gasket and clamp on the feed and retentate ports.

Seal the permeate port with a short piece of tubing i.d. 13 mm, which is secured using snapper clamp or cable tie wrap. The end is closed with pinch clamp, snapper clamp or cable tie wrap.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Gasket 50 mm (1.5") TC i.d. 38 mm, silicone 56410996 88.79 USD Add to cart
Get Quote
3 Clamp 50 mm (1.5") TC (Toggle Clamp) 56410669 75.77 USD Add to cart
Get Quote
4 Peristaltic Tubing, size 82, 7.6 m, i.d. 13 mm, bioprene 56410622 570.00 USD Add to cart
Get Quote
4 Peristaltic Tubing, size 82, 7.6 m, i.d. 13 mm, silicone 56410623 607.00 USD Add to cart
Get Quote
6 Tubing Connector Kit for FlexStand Standard System 56410764 770.00 USD Add to cart
Get Quote
Peristaltic Pump Dual Voltage 56410653 2 658.00 USD Add to cart
Get Quote
Clamp 50 mm TC 56410667 113.65 USD Add to cart
Get Quote
Clamp 50 mm TC 56410668 75.77 USD Add to cart
Get Quote
Clamp 64 mm (2") TC 56410670 85.24 USD Add to cart
Get Quote
Manual Permeate Control Kit, includes vacuum/pressure gauge, backpressure valve, supports, adapters, clamps, and gaskets 56410773 2 147.00 USD Add to cart
Get Quote
50 mm (1.5") TC Blank-Off Cap, polysulfone 56410990 86.43 USD Add to cart
Get Quote
Gasket 64 mm (2") TC i.d. 50 mm, silicone 56410998 105.37 USD Add to cart
Get Quote

Troubleshooting

Find solutions to product related issues. For unlisted issues please contact local Cytiva service representation.

General Advice for Troubleshooting when Using Cross Flow Filters

Please check the following items during troubleshooting:

Samples volume and system working volume have been used in calculations of concentration factor and diafiltration beforehand.

Process settings of Membrane Capacity, Flux, Shear (or volumetric cross flow rate) have been properly applied for both sample characteristics and membrane pore size or NMWC designation.

Filter is properly wetted before use (also make sure that there is no air lock in the filters created by condensation on microfiltration membranes as a result of incorrect autoclave settings).

Ensure CFF filters are properly wetted before starting processing. This may be tested against new cartridge “Clean Water Flux Test or against the water flux specifications in the Certificate of Quality. Microfitlration membranes are shipped dry and are rewetted with water or buffer. Hollow fiber ultrafiltration membranes are shipped in glycerol wetting preservative. These filters may require 15-20% alcohol/water solution to restore wetting or remove glycerol. Flat sheet cassette ultrafiltration devices (for example, KvickLab and KvickFlow Cassettes) are shipped in a solution of NaOH/Glycerol which must be flushed out before use.

Prior to using cassettes, make sure the single gasket is in the correct position in the holding device and that the cassette(s) within are oriented properly in the holder.

Check integrity of cassette system using water under pressure on retentate side to 1 barg to check for leaks in the seal of the cassette with the stainless steel holding device.

Check to see that cartridges or cassettes that have been previously used are checked for integrity (air diffusion or bubble point tests) and for cleanliness (normalized Clean Water Permeability before processing).

Contact