FAQ

Accessories

Please note that the numbers are not necessarily in sequential order.

Pressure gauge assembly (part of Adaptor kit 56-4115-32, item no 14 in the component list) includes pressure gauge with CPM connectors, CPM fitting, CPM O-ring and Clamp 50 mm TC.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Gasket o.d. 25 mm i.d 13 mm (0.5 inch) 56411286 11.38 USD Add to cart
3 Clamp 25 mm TC 56410665 161.46 USD Add to cart
6 25 mm TC i.d.13 mm (0.5") - 9.5 mm (0.375") Hose Barb 56411397 117.99 USD Add to cart
7 Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 171.81 USD Add to cart
9 Diaphragm Valve 25 mm (0.5") TC Connections, stainless steel 56411295 1,169.00 USD Add to cart
Clamp 50 mm TC 56410667 117.99 USD Add to cart
Gasket 25 mm (0.5") TC i.d. 13 mm, silicone 56410994 78.66 USD Add to cart
Gasket 25 mm (0.75") TC i.d. 19 mm, silicone 56410995 78.66 USD Add to cart
Gasket 50 mm (1.5") TC i.d. 38 mm, silicone 56410996 92.12 USD Add to cart
CPM O-Ring 56411389 162.49 USD Add to cart

When running FlexStand Holder with peristaltic pump, the maximum pressure that can be achieved is 2 bar g (30 psi g).

The use of a permeate flow control is strongly recommended during upstream clarification of target material. 

A permeate flow control kit together with a pump for the flow rate is required for permeate flow control. Permeate flow control rate is dependent on the process flux (LMH) and surface area. 

Detailed information about Permeate control valve (56-4105-89) and Permeate flow control kit (56-4107-73), is available below.

Suitable peristaltic pump (56-4106-53) for permeate flow control, flow rates 5.4 ml/min - 2 liter/min. Information available below.

Countries using 220 V power, have to order power cords separately for the pump above and system.

Feed pump (11-0005-66 or 11-0005-67), Feed reservoir (56-4107-67 or 56-4107-70), Outlet pressure gauge for FS-03LVS (56-4106-04), Outlet pressure gauge for FS-03LVS-30 ( 56-4106-03) and Tubing (56-4106-19, 56-4106-22 or 56-4105-23) have to be ordered separately.

After use, store the cartridge with liquid inside using blank off cap, gasket and clamp on the feed and retentate ports.

Seal the permeate port with a short piece of tubing i.d. 9.5 mm, which is secured using snapper clamp or cable tie wrap. The end is closed with snapper clamp or cable tie wrap.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Gasket 25 mm (0.5") TC i.d. 13 mm, silicone 56410994 78.66 USD Add to cart
3 Clamp 25 mm TC 56410665 161.46 USD Add to cart
4 Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 171.81 USD Add to cart
5 Tubing Valve for Tubing o.d. 9.5 mm–13 mm 56410589 77.62 USD Add to cart
Pressure Gauge 0-2 barg (0-30 psig) 50 mm (1.5") TC, back mount, autoclavable 56410603 998.00 USD Add to cart
Pressure Gauge 0-4 barg (0-60 psig) 50 mm (1.5") TC, back mount, autoclavable 56410604 998.00 USD Add to cart
Peristaltic Tubing, size 82, 7.6 m, i.d. 13 mm, bioprene 56410622 590.00 USD Add to cart
Peristaltic Tubing, size 82, 7.6 m, i.d. 13 mm, silicone 56410623 628.00 USD Add to cart
Clamp 25 mm TC 56410666 115.92 USD Add to cart
Clamp 64 mm (2") TC 56410670 87.98 USD Add to cart
Manual Permeate Control Kit, includes vacuum/pressure gauge, backpressure valve, supports, adapters, clamps, and gaskets 56410773 2,222.00 USD Add to cart
25 mm (0.5") TC Blank-Off Cap, polysulfone 56410989 61.06 USD Add to cart
Gasket 64 mm (2") TC i.d. 50 mm, silicone 56410998 108.68 USD Add to cart

The use of a permeate flow control is strongly recommended during upstream clarification of target material.

A permeate control valve or a permeate flow control kit together with a pump for the flow rate is required for permeate flow control. Permeate flow control rate is dependent on the process flux (LMH) and surface area. Detailed information about Permeate control valve (56-4105-89) and Permeate flow control kit (56-4107-73), is available below.

Suitable peristaltic pump (56-4106-53) for permeate flow control, flow rates 5.4 ml/min - 2 liter/min.

Countries using 220 V power, have to order power cords separately for the feed and permeate flow control pumps.

 

 

After use, store the cartridge with liquid inside using blank off cap, gasket and clamp on the feed and retentate ports.

Seal the permeate port with a short piece of tubing i.d. 9.5 mm, which is secured using cable tie wrap. The end is closed with pinch clamp or cable tie wrap.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
3 Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 171.81 USD Add to cart
4 Tubing Valve for Tubing o.d. 9.5 mm–13 mm 56410589 77.62 USD Add to cart
4 Manual Permeate Control Kit, includes vacuum/pressure gauge, backpressure valve, supports, adapters, clamps, and gaskets 56410773 2,222.00 USD Add to cart
5 Gasket 25 mm (0.5") TC i.d. 13 mm, silicone 56410994 78.66 USD Add to cart
6 Clamp 25 mm TC 56410665 161.46 USD Add to cart
6 Clamp 25 mm TC 56410666 115.92 USD Add to cart
8 Pressure Gauge 0-2 barg (0-30 psig) 25 mm (0.75") TC, side mount 56410600 1,398.00 USD Add to cart
9 25 mm TC 13 mm (0.5") Barb 56410981 202.00 USD Add to cart
10 Gasket 25 mm (0.75") TC i.d. 19 mm, silicone 56410995 78.66 USD Add to cart
11 Peristaltic Tubing, size 82, 7.6 m, i.d. 13 mm, bioprene 56410622 590.00 USD Add to cart
11 Peristaltic Tubing, size 82, 7.6 m, i.d. 13 mm, silicone 56410623 628.00 USD Add to cart
25 mm (0.5") TC Blank-Off Cap, polysulfone 56410989 61.06 USD Add to cart

The use of a permeate flow control is strongly recommended during upstream clarification of target material. 

A permeate flow control kit together with a pump for the flow rate is required for permeate flow control. Permeate flow control rate is dependent on the process flux (LMH) and surface area. Detailed information about Permeate control valve (56-4105-89) and Permeate flow control kit (56-4107-73), is available below.

Suitable peristaltic pump (56-4106-53) for permeate flow control, flow rates 5.4 ml/min - 2 liter/min.

Feed reservoir (56-4107-67 or 56-4107-70) has to be ordered separately. Detailed information can be found below.

Countries using 220 V power, have to order power cords separately for the pump above and system.

 

After use, store the cartridge with liquid inside using blank off cap, gasket and clamp on the feed and retentate ports.

Seal the permeate port with a short piece of tubing i.d. 9.5 mm, which is secured using snapper clamp or cable tie wrap. The end is closed with snapper clamp or cable tie wrap.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Gasket 25 mm (0.5") TC i.d. 13 mm, silicone 56410994 78.66 USD Add to cart
3 Clamp 25 mm TC 56410665 161.46 USD Add to cart
4 Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 171.81 USD Add to cart
5 Tubing Valve for Tubing o.d. 9.5 mm–13 mm 56410589 77.62 USD Add to cart
Clamp 25 mm TC 56410666 115.92 USD Add to cart
Clamp 64 mm (2") TC 56410670 87.98 USD Add to cart
Manual Permeate Control Kit, includes vacuum/pressure gauge, backpressure valve, supports, adapters, clamps, and gaskets 56410773 2,222.00 USD Add to cart
25 mm (0.5") TC Blank-Off Cap, polysulfone 56410989 61.06 USD Add to cart
Gasket 64 mm (2") TC i.d. 50 mm, silicone 56410998 108.68 USD Add to cart

Please note that the numbers are not necessarily in sequential order.

Pressure gauge assembly (part of Adaptor kit 56-4115-32, item no 14 in the component list) includes pressure gauge with CPM connectors, CPM fitting, CPM O-ring and Clamp 50 mm TC.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Gasket o.d. 25 mm i.d 13 mm (0.5 inch) 56411286 11.38 USD Add to cart
3 Clamp 25 mm TC 56410665 161.46 USD Add to cart
6 25 mm TC i.d.13 mm (0.5") - 9.5 mm (0.375") Hose Barb 56411397 117.99 USD Add to cart
7 Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 171.81 USD Add to cart
Peristaltic Pump P-1 18111091 3,793.00 USD Add to cart
Clamp 50 mm TC 56410667 117.99 USD Add to cart
Gasket 25 mm (0.75") TC i.d. 19 mm, silicone 56410995 78.66 USD Add to cart
Kvick Lab Pressure Gauge Kit, 0–4 bar 56411369 5,307.00 USD Add to cart
CPM O-Ring 56411389 162.49 USD Add to cart

The use of a permeate flow control is strongly recommended during upstream clarification of target material. 

A permeate control valve or a permeate flow control kit together with a pump for the flow rate is required for permeate flow control. Permeate flow control rate is dependent on the process flux (LMH) and surface area. Detailed information about Permeate control valve (56-4105-89) and Permeate flow control kit (56-4107-73), is available below.

Suitable peristaltic pump (56-4106-53) for permeate flow control, flow rates 5.4 ml/min - 2 liter/min.

For countries using 220 V power, power cords have to be ordered separately for the pump above and system.

After use, store the cartridge with liquid inside using blank off cap, gasket and clamp on the feed and retentate ports.

Seal the permeate port with a short piece of tubing i.d. 9.5 mm, which is secured using snapper clamp or cable tie wrap. The end is closed with snapper clamp or cable tie wrap.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Gasket 25 mm (0.5") TC i.d. 13 mm, silicone 56410994 78.66 USD Add to cart
3 Clamp 25 mm TC 56410665 161.46 USD Add to cart
3 Clamp 25 mm TC 56410666 115.92 USD Add to cart
4 Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 171.81 USD Add to cart
5 Tubing Valve for Tubing o.d. 9.5 mm–13 mm 56410589 77.62 USD Add to cart
Manual Permeate Control Kit, includes vacuum/pressure gauge, backpressure valve, supports, adapters, clamps, and gaskets 56410773 2,222.00 USD Add to cart
25 mm (0.5") TC Blank-Off Cap, polysulfone 56410989 61.06 USD Add to cart

The use of a permeate flow control is strongly recommended during upstream clarification of target material. 

A permeate control valve together with a pump for the flow rate is required for permeate flow control. Permeate flow control rate is dependent on the process flux (LMH) and surface area. Detailed information about Permeate control valve (56-4105-89) and peristaltic pump, flow rates 5.4 ml/min - 2 liter/min (56-4106-53), is available below.

For countries using 220 V power, power cords have to be ordered separately for the pump, model no PRP-09WM, code no 56-4106-53.

After use, store the cartridge with liquid inside using blank off cap, gasket and clamp on the feed and retentate ports.

Seal the permeate port with a short piece of tubing i.d. 9.5 mm, which is secured using snapper clamp or cable tie wrap. The end is closed with snapper clamp or cable tie wrap.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Gasket o.d. 25 mm i.d 13 mm (0.5 inch) 56411286 11.38 USD Add to cart
3 Clamp 25 mm TC 56410665 161.46 USD Add to cart
4 Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 171.81 USD Add to cart
5 Tubing Valve for Tubing o.d. 9.5 mm–13 mm 56410589 77.62 USD Add to cart
7 Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 171.81 USD Add to cart
Clamp 25 mm TC 56410666 115.92 USD Add to cart
25 mm (0.5") TC Blank-Off Cap, polysulfone 56410989 61.06 USD Add to cart

Troubleshooting

Find solutions to product related issues. For unlisted issues please contact local Cytiva service representation.

General Advice for Troubleshooting when Using Cross Flow Filters

Please check the following items during troubleshooting:

Samples volume and system working volume have been used in calculations of concentration factor and diafiltration beforehand.

Process settings of Membrane Capacity, Flux, Shear (or volumetric cross flow rate) have been properly applied for both sample characteristics and membrane pore size or NMWC designation.

Filter is properly wetted before use (also make sure that there is no air lock in the filters created by condensation on microfiltration membranes as a result of incorrect autoclave settings).

Ensure CFF filters are properly wetted before starting processing. This may be tested against new cartridge “Clean Water Flux Test or against the water flux specifications in the Certificate of Quality. Microfitlration membranes are shipped dry and are rewetted with water or buffer. Hollow fiber ultrafiltration membranes are shipped in glycerol wetting preservative. These filters may require 15-20% alcohol/water solution to restore wetting or remove glycerol. Flat sheet cassette ultrafiltration devices (for example, KvickLab and KvickFlow Cassettes) are shipped in a solution of NaOH/Glycerol which must be flushed out before use.

Prior to using cassettes, make sure the single gasket is in the correct position in the holding device and that the cassette(s) within are oriented properly in the holder.

Check integrity of cassette system using water under pressure on retentate side to 1 barg to check for leaks in the seal of the cassette with the stainless steel holding device.

Check to see that cartridges or cassettes that have been previously used are checked for integrity (air diffusion or bubble point tests) and for cleanliness (normalized Clean Water Permeability before processing).

Contact