FAQ

Accessories

Please note that the numbers are not necessarily in sequential order.

Pressure gauge assembly (part of Adaptor kit 56-4115-32, item no 14 in the component list) includes pressure gauge with CPM connectors, CPM fitting, CPM O-ring and Clamp 50 mm TC.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Gasket o.d. 25 mm i.d 13 mm (0.5 inch) 56411286 10.66 USD Add to cart
Get Quote
3 Clamp 25 mm TC 56410665 156.27 USD Add to cart
Get Quote
6 25 mm TC i.d.13 mm (0.5") - 9.5 mm (0.375") Hose Barb 56411397 108.92 USD Add to cart
Get Quote
7 Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 165.75 USD Add to cart
Get Quote
9 Diaphragm Valve 25 mm (0.5") TC Connections, stainless steel 56411295 1 129.00 USD Add to cart
Get Quote
Clamp 50 mm TC 56410667 113.65 USD Add to cart
Get Quote
Gasket 25 mm (0.5") TC i.d. 13 mm, silicone 56410994 75.77 USD Add to cart
Get Quote
Gasket 25 mm (0.75") TC i.d. 19 mm, silicone 56410995 75.77 USD Add to cart
Get Quote
Gasket 50 mm (1.5") TC i.d. 38 mm, silicone 56410996 88.79 USD Add to cart
Get Quote
CPM O-Ring 56411389 157.45 USD Add to cart
Get Quote

When running FlexStand Holder with peristaltic pump, the maximum pressure that can be achieved is 2 bar g (30 psi g).

The use of a permeate flow control is strongly recommended during upstream clarification of target material. 

A permeate flow control kit together with a pump for the flow rate is required for permeate flow control. Permeate flow control rate is dependent on the process flux (LMH) and surface area. 

Detailed information about Permeate control valve (56-4105-89) and Permeate flow control kit (56-4107-73), is available below.

Suitable peristaltic pump (56-4106-53) for permeate flow control, flow rates 5.4 ml/min - 2 liter/min. Information available below.

Countries using 220 V power, have to order power cords separately for the pump above and system.

Feed pump (11-0005-66 or 11-0005-67), Feed reservoir (56-4107-67 or 56-4107-70), Outlet pressure gauge for FS-03LVS (56-4106-04), Outlet pressure gauge for FS-03LVS-30 ( 56-4106-03) and Tubing (56-4106-19, 56-4106-22 or 56-4105-23) have to be ordered separately.

After use, store the cartridge with liquid inside using blank off cap, gasket and clamp on the feed and retentate ports.

Seal the permeate port with a short piece of tubing i.d. 9.5 mm, which is secured using snapper clamp or cable tie wrap. The end is closed with snapper clamp or cable tie wrap.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Gasket 25 mm (0.5") TC i.d. 13 mm, silicone 56410994 75.77 USD Add to cart
Get Quote
3 Clamp 25 mm TC 56410665 156.27 USD Add to cart
Get Quote
4 Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 165.75 USD Add to cart
Get Quote
5 Tubing Valve for Tubing o.d. 9.5 mm–13 mm 56410589 74.58 USD Add to cart
Get Quote
Pressure Gauge 0-2 barg (0-30 psig) 50 mm (1.5") TC, back mount, autoclavable 56410603 964.00 USD Add to cart
Get Quote
Pressure Gauge 0-4 barg (0-60 psig) 50 mm (1.5") TC, back mount, autoclavable 56410604 964.00 USD Add to cart
Get Quote
Peristaltic Tubing, size 82, 7.6 m, i.d. 13 mm, bioprene 56410622 570.00 USD Add to cart
Get Quote
Peristaltic Tubing, size 82, 7.6 m, i.d. 13 mm, silicone 56410623 607.00 USD Add to cart
Get Quote
Clamp 25 mm TC 56410666 111.50 USD Add to cart
Get Quote
Clamp 64 mm (2") TC 56410670 85.24 USD Add to cart
Get Quote
Manual Permeate Control Kit, includes vacuum/pressure gauge, backpressure valve, supports, adapters, clamps, and gaskets 56410773 2 147.00 USD Add to cart
Get Quote
25 mm (0.5") TC Blank-Off Cap, polysulfone 56410989 59.31 USD Add to cart
Get Quote
Gasket 64 mm (2") TC i.d. 50 mm, silicone 56410998 105.37 USD Add to cart
Get Quote

The use of a permeate flow control is strongly recommended during upstream clarification of target material.

A permeate control valve or a permeate flow control kit together with a pump for the flow rate is required for permeate flow control. Permeate flow control rate is dependent on the process flux (LMH) and surface area. Detailed information about Permeate control valve (56-4105-89) and Permeate flow control kit (56-4107-73), is available below.

Suitable peristaltic pump (56-4106-53) for permeate flow control, flow rates 5.4 ml/min - 2 liter/min.

Countries using 220 V power, have to order power cords separately for the feed and permeate flow control pumps.

 

 

After use, store the cartridge with liquid inside using blank off cap, gasket and clamp on the feed and retentate ports.

Seal the permeate port with a short piece of tubing i.d. 9.5 mm, which is secured using cable tie wrap. The end is closed with pinch clamp or cable tie wrap.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
3 Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 165.75 USD Add to cart
Get Quote
4 Tubing Valve for Tubing o.d. 9.5 mm–13 mm 56410589 74.58 USD Add to cart
Get Quote
4 Manual Permeate Control Kit, includes vacuum/pressure gauge, backpressure valve, supports, adapters, clamps, and gaskets 56410773 2 147.00 USD Add to cart
Get Quote
5 Gasket 25 mm (0.5") TC i.d. 13 mm, silicone 56410994 75.77 USD Add to cart
Get Quote
6 Clamp 25 mm TC 56410665 156.27 USD Add to cart
Get Quote
6 Clamp 25 mm TC 56410666 111.50 USD Add to cart
Get Quote
8 Pressure Gauge 0-2 barg (0-30 psig) 25 mm (0.75") TC, side mount 56410600 1 351.00 USD Add to cart
Get Quote
9 25 mm TC 13 mm (0.5") Barb 56410981 195.34 USD Add to cart
Get Quote
10 Gasket 25 mm (0.75") TC i.d. 19 mm, silicone 56410995 75.77 USD Add to cart
Get Quote
11 Peristaltic Tubing, size 82, 7.6 m, i.d. 13 mm, bioprene 56410622 570.00 USD Add to cart
Get Quote
11 Peristaltic Tubing, size 82, 7.6 m, i.d. 13 mm, silicone 56410623 607.00 USD Add to cart
Get Quote
Peristaltic Pump Dual Voltage 56410653 2 658.00 USD Add to cart
Get Quote
25 mm (0.5") TC Blank-Off Cap, polysulfone 56410989 59.31 USD Add to cart
Get Quote

The use of a permeate flow control is strongly recommended during upstream clarification of target material. 

A permeate flow control kit together with a pump for the flow rate is required for permeate flow control. Permeate flow control rate is dependent on the process flux (LMH) and surface area. Detailed information about Permeate control valve (56-4105-89) and Permeate flow control kit (56-4107-73), is available below.

Suitable peristaltic pump (56-4106-53) for permeate flow control, flow rates 5.4 ml/min - 2 liter/min.

Feed reservoir (56-4107-67 or 56-4107-70) has to be ordered separately. Detailed information can be found below.

Countries using 220 V power, have to order power cords separately for the pump above and system.

 

After use, store the cartridge with liquid inside using blank off cap, gasket and clamp on the feed and retentate ports.

Seal the permeate port with a short piece of tubing i.d. 9.5 mm, which is secured using snapper clamp or cable tie wrap. The end is closed with snapper clamp or cable tie wrap.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Gasket 25 mm (0.5") TC i.d. 13 mm, silicone 56410994 75.77 USD Add to cart
Get Quote
3 Clamp 25 mm TC 56410665 156.27 USD Add to cart
Get Quote
4 Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 165.75 USD Add to cart
Get Quote
5 Tubing Valve for Tubing o.d. 9.5 mm–13 mm 56410589 74.58 USD Add to cart
Get Quote
Peristaltic Pump Dual Voltage 56410653 2 658.00 USD Add to cart
Get Quote
Clamp 25 mm TC 56410666 111.50 USD Add to cart
Get Quote
Clamp 64 mm (2") TC 56410670 85.24 USD Add to cart
Get Quote
Manual Permeate Control Kit, includes vacuum/pressure gauge, backpressure valve, supports, adapters, clamps, and gaskets 56410773 2 147.00 USD Add to cart
Get Quote
25 mm (0.5") TC Blank-Off Cap, polysulfone 56410989 59.31 USD Add to cart
Get Quote
Gasket 64 mm (2") TC i.d. 50 mm, silicone 56410998 105.37 USD Add to cart
Get Quote

Please note that the numbers are not necessarily in sequential order.

Pressure gauge assembly (part of Adaptor kit 56-4115-32, item no 14 in the component list) includes pressure gauge with CPM connectors, CPM fitting, CPM O-ring and Clamp 50 mm TC.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Gasket o.d. 25 mm i.d 13 mm (0.5 inch) 56411286 10.66 USD Add to cart
Get Quote
3 Clamp 25 mm TC 56410665 156.27 USD Add to cart
Get Quote
6 25 mm TC i.d.13 mm (0.5") - 9.5 mm (0.375") Hose Barb 56411397 108.92 USD Add to cart
Get Quote
7 Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 165.75 USD Add to cart
Get Quote
Peristaltic Pump P-1 18111091 3 332.00 USD Add to cart
Get Quote
Clamp 50 mm TC 56410667 113.65 USD Add to cart
Get Quote
Gasket 25 mm (0.75") TC i.d. 19 mm, silicone 56410995 75.77 USD Add to cart
Get Quote
Kvick Lab Pressure Gauge Kit, 0–4 bar 56411369 5 128.00 USD Add to cart
Get Quote
CPM O-Ring 56411389 157.45 USD Add to cart
Get Quote

Issue: This technical brief will describe the fittings and tubing required to physically connect a size 3M(A) or 4M(A) hollow fiber cartridge to the ÄKTAcrossflow system. The maximum feed flow rate on ÄKTAcrossflow is 600 ml/min.

Hollow Fiber Cartridge Housing Information:

Housing 3M Housing 4M
Permeate Ports = 6.4 mm (0.25 inch) hose barb Permeate Ports = 9.5 mm (0.375 inch) hose barb
Feed/Retentate Ports = 25 mm TC Feed/Retentate Ports =25 mm TC

 

Fittings for Feed & Retentate Ports:

Code no Model no Description Qty/pack Minimum Quality Purpose/Comments
18-1169-22 - Connector 25 mm - 5/16 female 2 2 x Connector Connect feed and retentate ports to system
18-1169-25 - Gasket 25 mm TC i.d. 6.4 mm (0.25 inch) 4 2 x Gasket Seal connector to feed and retentate ports
or          
56-4109-94 KG4S Gasket 25 mm TC i.d. 13 mm (0.5 inch) 4 2 x Gasket  
18-1169-18 - Clamp 25 mm TC 4 2 x Clamp Clamp connector and gaskets to feed and retentate ports

 

Fittings for Permeate Ports:

Code no Model no Description Qty/pack Minimum Quality Purpose/Comments
18-1127-76* - Connector 5/16 female - M6 male 3 1 x Fitting Connect system permeate tubing to permeate port
18-1169-43* - Connector M6 female - Luer male 5 1 x Fitting Bridge connection from system to cartridge
56-4105-75 RBFL-1 Luer female - 3.1 mm (0.125 inch) barb 10 1 x Fitting Bridge connection from system to cartridge
56-4106-17 PTSL03-10 Tubing i.d. 3.1 mm (0.125 inch) L = 3.1 m L = 0.25 m Bridge connection, for Size 3 cartridge permeate port
56-4106-18 PTPM0&-10 Tubing i.d. 6.4 mm (0.25 inch) L 0 3.1 m L 0 9.25 m Bridge connection, for Size 3 or 4 cartridge permeate port
Not applicable - Cable Ties   4 x Cable ties Secure tubing

*included in ÄKTAcrossflow accessory kit

 

Nominal Feed Flow Rates:

Hosing Size Nominal fiber i.d. (mm) Shear Rate 2000 sec-1 (ml/min) Shear Rate 4000 sec-1 (ml/min) Shear Rate 8000 sec-1 (ml/min) Shear Rate 16000 sec-1 (ml/min)
3M 0.5 63 125 251 502
  1.0 153 306 613 1225
4M 0.5 293 586 1171 2342
  1.0 589 1178 2356 4172

NOTE: The shaded area represents possible application on ÄKTAcrossflow. Each set of conditions must be tested with the particular feed stream and flux set point. For more information consult the Cytiva Operating Handbook, 18-1165-30, or contact your local representative.

 

Connection of Size 3 Hollow Fiber Cartridge to ÄKTAcrossflow:

 

Feed & Retentate Ports: Place gasket between end port and connector 25 mm TC - 5/16 female, (18-1169-22). Secure with clamp.

Lower Permeate Port: Connect tubing i.d. 3.1 mm or 6.4 mm (56-4106-17, PTSL03-10 or 56-4106-18, PTPM06-10). Fold over tubing. Secure with cable ties.

Upper Permeate Port: Connect at least 2.5 cm tubing i.d. 3.1 mm or 6.4 m. Secure with cable ties.

Connect connector Luer female - 3.1 mm (0.125 inch) barb (56-4105-75, RBFL-1) >> M6 female - Luer male (11-0026-43) >> 5/16 female - M6 male (18-1127-76) >> system permeate connection.

 

Connection of Size 4 Hollow Fiber to ÄKTAcrossflow:

 

Feed & Retentate Ports: Place gasket between end port and connector 25 mm TC - 5/16 female, (18-1169-22). Secure with clamp.

Lower Permeate Port: Connect tubing i.d. 6.4 mm (56-4106-18, PTPM06-10). Fold over tubing. Secure with cable ties.

Upper Permeate Port: Connect at least 2.5 cm tubing i.d. 6.4 mm. Secure with cable ties.

Connect connector Luer female - 3.1 mm (0.125 inch) barb (56-4105-75, RBFL-1) >> M6 female - Luer male (11-0026-43) >> 5/16 female - M6 male (18-1127-76) >> system permeate connection.

NOTE: Snapper clamps are delivered with hollow fiber cartridges. They may be used to secure tubing to the lower and upper permeate port barbs. Use pliers to secure the fitting. Check for leaks before loading sample.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Connector, 25 mm TC - UNF 5/16" Female 18116922 176.74 USD Add to cart
Get Quote
2 TC Gasket, 25 mm, i.d. 6.5 mm 18116925 452.00 USD Add to cart
Get Quote
3 Gasket 25 mm (0.5") TC i.d. 13 mm, silicone 56410994 75.77 USD Add to cart
Get Quote
4 ÄKTApilot Clamp, 25 mm TC 18116918 285.00 USD Add to cart
Get Quote
5 Connector 5/16" Female - M6 Male 18112776 60.50 USD Add to cart
Get Quote
6 Luer Lock Male/M6 Female for ÄKTAcrossflow 11002643 367.00 USD Add to cart
Get Quote
7 Connector Luer Female - 3.2 mm (0.125") Barb 56410575 28.41 USD Add to cart
Get Quote
8 Peristaltic Tubing, size 16, 3.1 m, i.d. 3.1 mm, silicone 56410617 130.23 USD Add to cart
Get Quote
9 Peristaltic Tubing, size 17, 3.1 m, i.d. 6.4 mm, bioprene 56410618 147.98 USD Add to cart
Get Quote

The use of a permeate flow control is strongly recommended during upstream clarification of target material. 

A permeate control valve or a permeate flow control kit together with a pump for the flow rate is required for permeate flow control. Permeate flow control rate is dependent on the process flux (LMH) and surface area. Detailed information about Permeate control valve (56-4105-89) and Permeate flow control kit (56-4107-73), is available below.

Suitable peristaltic pump (56-4106-53) for permeate flow control, flow rates 5.4 ml/min - 2 liter/min.

For countries using 220 V power, power cords have to be ordered separately for the pump above and system.

After use, store the cartridge with liquid inside using blank off cap, gasket and clamp on the feed and retentate ports.

Seal the permeate port with a short piece of tubing i.d. 9.5 mm, which is secured using snapper clamp or cable tie wrap. The end is closed with snapper clamp or cable tie wrap.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Gasket 25 mm (0.5") TC i.d. 13 mm, silicone 56410994 75.77 USD Add to cart
Get Quote
3 Clamp 25 mm TC 56410665 156.27 USD Add to cart
Get Quote
3 Clamp 25 mm TC 56410666 111.50 USD Add to cart
Get Quote
4 Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 165.75 USD Add to cart
Get Quote
5 Tubing Valve for Tubing o.d. 9.5 mm–13 mm 56410589 74.58 USD Add to cart
Get Quote
Peristaltic Pump Dual Voltage 56410653 2 658.00 USD Add to cart
Get Quote
Manual Permeate Control Kit, includes vacuum/pressure gauge, backpressure valve, supports, adapters, clamps, and gaskets 56410773 2 147.00 USD Add to cart
Get Quote
25 mm (0.5") TC Blank-Off Cap, polysulfone 56410989 59.31 USD Add to cart
Get Quote

The use of a permeate flow control is strongly recommended during upstream clarification of target material. 

A permeate control valve together with a pump for the flow rate is required for permeate flow control. Permeate flow control rate is dependent on the process flux (LMH) and surface area. Detailed information about Permeate control valve (56-4105-89) and peristaltic pump, flow rates 5.4 ml/min - 2 liter/min (56-4106-53), is available below.

For countries using 220 V power, power cords have to be ordered separately for the pump, model no PRP-09WM, code no 56-4106-53.

After use, store the cartridge with liquid inside using blank off cap, gasket and clamp on the feed and retentate ports.

Seal the permeate port with a short piece of tubing i.d. 9.5 mm, which is secured using snapper clamp or cable tie wrap. The end is closed with snapper clamp or cable tie wrap.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Gasket o.d. 25 mm i.d 13 mm (0.5 inch) 56411286 10.66 USD Add to cart
Get Quote
3 Clamp 25 mm TC 56410665 156.27 USD Add to cart
Get Quote
4 Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 165.75 USD Add to cart
Get Quote
5 Tubing Valve for Tubing o.d. 9.5 mm–13 mm 56410589 74.58 USD Add to cart
Get Quote
7 Peristaltic Tubing, size 18, 3.1 m, i.d. 9.5 mm, bioprene 56410619 165.75 USD Add to cart
Get Quote
Peristaltic Pump Dual Voltage 56410653 2 658.00 USD Add to cart
Get Quote
Clamp 25 mm TC 56410666 111.50 USD Add to cart
Get Quote
25 mm (0.5") TC Blank-Off Cap, polysulfone 56410989 59.31 USD Add to cart
Get Quote

Contact