O-rings and nets should be checked regularly for wear. Worn O-rings may not seal properly and over-used nets can affect distribution. Inspect the O-rings and evaluate the height equivalent to a theoretical plate (HETP) and peak asymmetry factor (As) to prevent poor performance due to old nets.

We recommend you to change the nets and O-rings when needed or at least annually. Please keep a set of each on your site, for the code numbers refer to the table below.

It could be useful to have unflanged tubing in stock, that could be cut in suitable length and flanged, to replace any damaged tubing.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Net for Columns, i.d 16 mm, 10 µm 18876101 76.88 USD Add to cart
2 Support Screen for Column, i.d. 16 mm 19065101 52.28 USD Add to cart
3 O-Ring, 10.3 × 2.4 mm 19016301 60.47 USD Add to cart
4 ETFE Tubing, 1.5 m, i.d. 0.75 mm, o.d. 1/16" 18111974 80.73 USD Add to cart
5 Ferrules for o.d. 1/16" tubing connector 18112706 159.39 USD Add to cart
6 Accessory kit XK 16 28989978 150.67 USD Add to cart
7 Column Holder 28956282 138.69 USD Add to cart

XK 16 Column

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Adapter XK 16 28989876 387.45 USD Add to cart
2 Stop Plug Female, 1/16" 11000464 103.52 USD Add to cart
3 Fingertight connector 1/16" male, narrow 28401081 108.65 USD Add to cart
4 ETFE Tubing, 1.5 m, i.d. 0.75 mm, o.d. 1/16" 18111974 80.73 USD Add to cart
9 Ferrules for o.d. 1/16" tubing connector 18112706 159.39 USD Add to cart
10 O-Ring, 10.3 × 2.4 mm 19016301 60.47 USD Add to cart
11 Plunger for XK 16 and AK 16 18103180 55.35 USD Add to cart
12 Support Screen for Column, i.d. 16 mm 19065101 52.28 USD Add to cart
13 Net for Columns, i.d 16 mm, 10 µm 18876101 76.88 USD Add to cart
14 End Piece Complete, XK16 18648801 109.68 USD Add to cart
17 XK 16/40 Tube 19011301 195.77 USD Add to cart
17 XK 16/70 Tube 19011401 311.60 USD Add to cart
17 XK 16/100 Tube 19011501 458.17 USD Add to cart
17 XK 16/20 Tube 19031501 157.85 USD Add to cart
18 XK 16, 20 cm Jacket 18001172 170.15 USD Add to cart
18 XK 16, 40 cm Jacket 18001173 197.82 USD Add to cart
18 XK 16, 70 cm Jacket 18001174 216.27 USD Add to cart
18 XK 16, 100 cm Jacket 18001175 338.25 USD Add to cart
22 Bottom Piece Complete for XK 16 Column 28989885 186.55 USD Add to cart
Tricorn Storage/Shipping Device 18117643 139.40 USD Add to cart

Accessories

Make sure you have all connectors and tubing needed for packing and running the column.

Depending on your system configuration and column length, you may need extra long tubing to connect your column.

By replacing the bottom unit with an additional adaptor a larger range of bed heights is obtained.

Gelfiltration chromatography movies  

Exchange of buffer

Preparing the column

Packing the column

Unpacking the columns

Adsorption chromatography movies  

Equipment required

Exchange of buffer

Preparing the column

Packing the column

Unpacking the columns

 
Column evaluation movie  

Column evaluation

 

 

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 ETFE Tubing, 1.5 m, i.d. 0.75 mm, o.d. 1/16" 18111974 80.73 USD Add to cart
2 Fingertight connector 1/16" male, narrow 28401081 108.65 USD Add to cart
3 Union 1/16" female-1/16" female 11000339 170.07 USD Add to cart
4 Stop Plug Female, 1/16" 11000464 103.52 USD Add to cart
5 XK 16/40 Tube 19011301 195.77 USD Add to cart
5 XK 16/70 Tube 19011401 311.60 USD Add to cart
5 XK 16/100 Tube 19011501 458.17 USD Add to cart
5 XK 16/20 Tube 19031501 157.85 USD Add to cart
6 Packing Connector XK 16 18115344 135.30 USD Add to cart
7 Packing reservoir RK 16/26 28989858 553.50 USD Add to cart

Make sure you have all connectors and tubing needed for running the column.
Depending on your system configuration and column length you may need extra long tubing to connect your column.
Please do not extend the tubing unnecessarily which results in a lower resolution.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 ETFE Tubing, 1.5 m, i.d. 0.75 mm, o.d. 1/16" 18111974 80.73 USD Add to cart
2 Fingertight connector 1/16" male, narrow 28401081 108.65 USD Add to cart
3 Union 1/16" female-1/16" female 11000339 170.07 USD Add to cart
4 Stop Plug Female, 1/16" 11000464 103.52 USD Add to cart

Troubleshooting

Find solutions to product related issues. For unlisted issues please contact local Cytiva service representation.

Poor product recovery

Select the description that fits with your symptom

Worrying peak shape

Select the description that fits with your symptom

Drifting baseline

Select the description that fits with your symptom

Poor reproducibility

Select the description that fits with your symptom

Poor packing evaluation result

On this troubleshooting site, we refer to leading and tailing peaks as defined according to the following figures.
 
 

Leading peak Tailing peak

 
Experience shows that the best method of expressing the efficiency of a packed column is in terms of its height equivalent to a theoretical plate (HETP), reduced plate number (h) and its peak asymmetry factor (As). 

Please be aware of that for small columns, less than 10 ml bed volume, the system dead volume has an impact on the column evaluation values.

Issues related to Poor packing evaluation result

General advice to achieve good performance

Before using the system make sure that:

  • The correct system has been selected in UNICORN System Control
  • The correct wavelength has been set for UV/UPC monitor
  • All tubing has been properly connected
  • All connectors are free from leakage
  • No tubing is folded or twisted
  • Online filter, if used, is changed on a regular basis
  • Correct buffers are used for the chosen columns and proteins
  • All inlet tubing has been immersed in correct buffer solutions
  • Enough buffer has been prepared
  • Buffers have been equilibrated to the environment temperature
  • Buffers/eluents have been degassed if necessary (e.g., in RPC runs)
  • Suitable columns have been selected for the target proteins
  • Columns have been cleaned and prepared according to column instructions
  • Samples have been clarified by centrifugation and/or filtration prior to sample loading
  • Samples have been adjusted to binding buffer conditions
  • Auto sampler (if used) has been prepared according to user manual
  • The fraction collector has been filled with appropriate number of microtiter plates or tubes
  • Appropriate arrangement for waste handling has been prepared

Column leakage

Select the description that fits with your symptom

Unsatisfactory elution

Select the description that fits with your symptom

Back pressure increases during operation

Unusual column appearance

Select the description that fits with your symptom

Strange peaks

Select the description that fits with your symptom

Contact