FAQ

Accessories

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Tubing, 1200 mm, i.d. 2.9 mm, o.d. 3/16", S8 18116975 202.00 USD Add to cart
Get Quote
2 Tubing, 400 mm, i.d. 2.9 mm, o.d. 3/16", S6 18116970 171.87 USD Add to cart
Get Quote
3 Connector, 25 mm TC - UNF 5/16" Female 18116922 176.74 USD Add to cart
Get Quote
4 TC Gasket, 25 mm, i.d. 4 mm 18116924 251.00 USD Add to cart
Get Quote

Figure. BPG 140, Accessories for Packing the column, parts identification.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Column Stand 140/200 Columns 18103120 2 353.00 USD Add to cart
Get Quote
2 Tubing, 300 mm, 25 mm TC, i.d. 6 mm 18000542 348.00 USD Add to cart
Get Quote
2 Tubing, 750 mm, 25 mm TC, i.d. 6 mm 18000543 372.00 USD Add to cart
Get Quote
2 Tubing, 1250 mm, 25 mm TC, i.d. 6 mm 18000544 378.00 USD Add to cart
Get Quote
2 Tubing, 1500 mm, 25 mm TC, i.d. 6 mm 18000545 391.00 USD Add to cart
Get Quote
2 Tubing, 2000 mm, 25 mm TC, i.d. 6 mm 18000547 438.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 50 cm, i.d. 6 mm, 25 mm TC 28405368 468.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 80 cm, i.d. 6 mm, 25 mm TC 28405369 491.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 1 m, i.d. 6 mm, 25 mm TC 28405370 495.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 2 m, i.d. 6 mm, 25 mm TC 28405371 630.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 4 m, i.d. 6 mm, 25 mm TC 28405372 765.00 USD Add to cart
Get Quote
3 Gasket 25 mm, i.d. 6 mm 18001927 15.42 USD Add to cart
Get Quote
3 Gaskets, 25 mm, i.d. 6 mm 18001928 35.61 USD Add to cart
Get Quote
3 TC-gasket 25/8 EPDM 28950948 61.81 USD Add to cart
Get Quote
4 TC Clamp kit TC25/SS 28404338 120.33 USD Add to cart
Get Quote
5 Valve 4-Port 2-Way ID 6 mm 18575701 1 694.00 USD Add to cart
Get Quote
6 Manometer Kit, 0-10 bar 18103107 3 113.00 USD Add to cart
Get Quote
7 Pressure Relief Valve for FineLINE 70,100, and 200 Columns 18110536 1 833.00 USD Add to cart
Get Quote
8 Safety Valve, 6 bar 18103581 3 313.00 USD Add to cart
Get Quote
9 T-Junction, 2 × 25 mm TC, i.d. 6 mm; 1 × 50 mm TC, i.d. 22 mm 28405765 914.00 USD Add to cart
Get Quote
10 Tubing with sanitary fittings, L=90 cm, i.d.19 mm, 51 mm TC 28404230 499.00 USD Add to cart
Get Quote
10 Tubing with sanitary fittings, L=200 cm, i.d.19 mm, 51 mm TC 28404232 3 322.00 USD Add to cart
Get Quote
10 Tubing with Sanitary Fittings, 400 cm, i.d.19 mm, 51 mm TC 28404233 1 410.00 USD Add to cart
Get Quote
10 Tubing with sanitary fittings, L=140 cm, i.d.19 mm, 51 mm TC 28404235 598.00 USD Add to cart
Get Quote
10 Tubing with Sanitary Fittings, 50 cm, i.d. 19.1 mm, 50 mm TC 28405379 2 141.00 USD Add to cart
Get Quote
10 Tubing with Sanitary Fittings, 80 cm, i.d. 19.1 mm, 50 mm TC 28405380 2 355.00 USD Add to cart
Get Quote
10 Tubing with Sanitary Fittings, 1 m, i.d. 19.1 mm, 50 mm TC 28405381 2 462.00 USD Add to cart
Get Quote
10 Tubing with Sanitary Fittings, 2 m, i.d. 19.1 mm, 50 mm TC 28405382 3 211.00 USD Add to cart
Get Quote
10 Tubing with Sanitary Fittings, 4 m, i.d. 19.1 mm, 50 mm TC 28405383 4 067.00 USD Add to cart
Get Quote
11 Gasket 51 mm 28966886 74.16 USD Add to cart
Get Quote
11 Gasket, 51 mm, i.d. 22 mm 44551203 83.32 USD Add to cart
Get Quote
12 Clamp, 50 mm TC, SS 44713401 10.68 USD Add to cart
Get Quote
13 Packing Device, BPG 140 Column 18111333 4 785.00 USD Add to cart
Get Quote
Torque Wrench for BPG Columns, 2-20 N 18025137 470.00 USD Add to cart
Get Quote
Blind Flange, including gasket, 25 mm 18100125 76.96 USD Add to cart
Get Quote
Allen Key for BPG Columns 18103098 33.15 USD Add to cart
Get Quote
12-Point Opening Socket for BPG 140–200 Columns 18103104 66.30 USD Add to cart
Get Quote
Media Stirrer, 80 mm diameter 28919103 235.00 USD Add to cart
Get Quote

Figure. BPG 140, Accessories for Running the column, parts identification.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Column Stand 140/200 Columns 18103120 2 353.00 USD Add to cart
Get Quote
2 Tubing, 300 mm, 25 mm TC, i.d. 6 mm 18000542 348.00 USD Add to cart
Get Quote
2 Tubing, 750 mm, 25 mm TC, i.d. 6 mm 18000543 372.00 USD Add to cart
Get Quote
2 Tubing, 1250 mm, 25 mm TC, i.d. 6 mm 18000544 378.00 USD Add to cart
Get Quote
2 Tubing, 1500 mm, 25 mm TC, i.d. 6 mm 18000545 391.00 USD Add to cart
Get Quote
2 Tubing, 2000 mm, 25 mm TC, i.d. 6 mm 18000547 438.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 50 cm, i.d. 6 mm, 25 mm TC 28405368 468.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 80 cm, i.d. 6 mm, 25 mm TC 28405369 491.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 1 m, i.d. 6 mm, 25 mm TC 28405370 495.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 2 m, i.d. 6 mm, 25 mm TC 28405371 630.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 4 m, i.d. 6 mm, 25 mm TC 28405372 765.00 USD Add to cart
Get Quote
3 Gasket 25 mm, i.d. 6 mm 18001927 15.42 USD Add to cart
Get Quote
3 Gaskets, 25 mm, i.d. 6 mm 18001928 35.61 USD Add to cart
Get Quote
3 TC-gasket 25/8 EPDM 28950948 61.81 USD Add to cart
Get Quote
4 TC Clamp kit TC25/SS 28404338 120.33 USD Add to cart
Get Quote
5 Valve 4-Port 2-Way ID 6 mm 18575701 1 694.00 USD Add to cart
Get Quote
6 Valve, 4-port, 4-way, i.d. 6 mm, 25 mm TC 18575801 1 934.00 USD Add to cart
Get Quote
7 Manometer Kit, 0-10 bar 18103107 3 113.00 USD Add to cart
Get Quote
8 Air Trap Complete 18110297 8 911.00 USD Add to cart
Get Quote
9 Safety Valve, 6 bar 18103581 3 313.00 USD Add to cart
Get Quote
10 T-Junction, 2 × 25 mm TC, i.d. 6 mm; 1 × 50 mm TC, i.d. 22 mm 28405765 914.00 USD Add to cart
Get Quote
11 Tubing with sanitary fittings, L=90 cm, i.d.19 mm, 51 mm TC 28404230 499.00 USD Add to cart
Get Quote
11 Tubing with sanitary fittings, L=200 cm, i.d.19 mm, 51 mm TC 28404232 3 322.00 USD Add to cart
Get Quote
11 Tubing with Sanitary Fittings, 400 cm, i.d.19 mm, 51 mm TC 28404233 1 410.00 USD Add to cart
Get Quote
11 Tubing with sanitary fittings, L=140 cm, i.d.19 mm, 51 mm TC 28404235 598.00 USD Add to cart
Get Quote
11 Tubing with Sanitary Fittings, 50 cm, i.d. 19.1 mm, 50 mm TC 28405379 2 141.00 USD Add to cart
Get Quote
11 Tubing with Sanitary Fittings, 80 cm, i.d. 19.1 mm, 50 mm TC 28405380 2 355.00 USD Add to cart
Get Quote
11 Tubing with Sanitary Fittings, 1 m, i.d. 19.1 mm, 50 mm TC 28405381 2 462.00 USD Add to cart
Get Quote
11 Tubing with Sanitary Fittings, 2 m, i.d. 19.1 mm, 50 mm TC 28405382 3 211.00 USD Add to cart
Get Quote
11 Tubing with Sanitary Fittings, 4 m, i.d. 19.1 mm, 50 mm TC 28405383 4 067.00 USD Add to cart
Get Quote
12 Gasket 51 mm 28966886 74.16 USD Add to cart
Get Quote
12 Gasket, 51 mm, i.d. 22 mm 44551203 83.32 USD Add to cart
Get Quote
13 Clamp, 50 mm TC, SS 44713401 10.68 USD Add to cart
Get Quote
14 Top Valve for Air Traps 18112144 1 510.00 USD Add to cart
Get Quote
16 Filter 215 nm 11000733 744.00 USD Add to cart
Get Quote
16 Filter 260 nm 11000734 710.00 USD Add to cart
Get Quote
16 Filter 280 nm 11000735 519.00 USD Add to cart
Get Quote
16 Filter 405 nm 11000736 679.00 USD Add to cart
Get Quote
16 Empty Filter Holder 11000738 222.00 USD Add to cart
Get Quote
16 Monitor UVis-920 Excluding Filter and Flow Cell 11000754 9 825.00 USD Add to cart
Get Quote
16 Short optical fibre kit, 200 mm 18113485 788.00 USD Add to cart
Get Quote
16 Long optical fibre kit, 500 mm 18113486 582.00 USD Add to cart
Get Quote
16 UV flow cell, i.d. 8 mm 28966687 3 025.00 USD Add to cart
Get Quote
16 O-ring kit 28969705 133.83 USD Add to cart
Get Quote
17 Flow cell, i.d. 6 mm, 25 mm TC 18100066 3 527.00 USD Add to cart
Get Quote
17 Filter Kit 280 nm 19243301 983.00 USD Add to cart
Get Quote
Torque Wrench for BPG Columns, 2-20 N 18025137 470.00 USD Add to cart
Get Quote
Allen Key for BPG Columns 18103098 33.15 USD Add to cart
Get Quote
12-Point Opening Socket for BPG 140–200 Columns 18103104 66.30 USD Add to cart
Get Quote
Grounding kit 18115787 191.20 USD Add to cart
Get Quote

Item Comment
1

For flow rates 3 l/h-175 l/h use Low Flow Kit 28-9301-82.

For flow rates 7.5 l/h-510 l/h use High Flow Kit 28-9301-83.

2 For Low Flow Kit use tubing with i.d. 6 mm and for High Flow Kit use tubing with i.d. 9.5 mm (PTFE) or 10 mm (PVC), refer to tables below.
3 TC Gasket 25 mm i.d. 15 mm 44-5492-88, two gaskets are supplied with the flow kit. Two gaskets i.d. 15 mm are needed to connect column to system.
4 TC Clamp 25 mm 28-4043-38 (Stainless steel) or 44-4043-36 (Polypropylene).
5

For Low Flow Kit use 4-port, 2-way Valve, i.d. 6 mm, 25 mm TC 18-5757-01.

For High Flow Kit use 4-port, 2-way Valve i.d. 10 mm, 25 mm TC 18-1012-56.

6

For Low Flow Kit use gasket with i.d. 6 mm 18-0019-27 or i.d. 8 mm 28-9509-48.

For High Flow Kit use gasket with i.d. 10 mm 18-1035-79.

To isolate the column from the system use 4-port, 2-way valves or alternatively only  TC End Cap, 25 mm TC incl. gaskets 18-1001-25  and TC Clamp 25 mm.

 

PTFE tubing with 25 mm TC

Inner Diameter Length Code Number
6 mm 0.5 m 28-4053-68
6 mm 0.8 m 28-4053-69
6 mm 1 m 28-4053-70
6 mm 2 m 28-4053-71
6 mm 4 m 28-4053-72
9.5 mm 0.5 m 28-4053-73
9.5 mm 0.8 m 28-4053-75
9.5 mm 1 m 28-4053-76
9.5 mm 2 m 28-4053-77
9.5 mm 4 m 28-4053-78

 

PVC tubing with 25 mm TC

Inner Diameter Length Code Number
6 mm 0.3 m 18-0005-42
6 mm 0.75 m 18-0005-43
6 mm 1.25 m 18-0005-44
6 mm 1.5 m 18-0005-45
6 mm 2 m 18-0005-47
10 mm 0.3 m 18-1012-85
10 mm 0.4 m 18-1012-86
10 mm 0.9 m 18-1012-62
10 mm 1.4 m 18-1012-63
10 mm 1.7 m 18-1012-64
10 mm 2 m 18-1012-87

 

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Tubing, 300 mm, 25 mm TC, i.d. 6 mm 18000542 348.00 USD Add to cart
Get Quote
2 Tubing, 750 mm, 25 mm TC, i.d. 6 mm 18000543 372.00 USD Add to cart
Get Quote
2 Tubing, 1250 mm, 25 mm TC, i.d. 6 mm 18000544 378.00 USD Add to cart
Get Quote
2 Tubing, 1500 mm, 25 mm TC, i.d. 6 mm 18000545 391.00 USD Add to cart
Get Quote
2 Tubing, 2000 mm, 25 mm TC, i.d. 6 mm 18000547 438.00 USD Add to cart
Get Quote
2 Tubing, 900 mm, 25 mm TC, i.d.10 mm 18101262 364.00 USD Add to cart
Get Quote
2 Tubing, 1400 mm, 25 mm TC, i.d.10 mm 18101263 382.00 USD Add to cart
Get Quote
2 Tubing, 1700 mm, 25 mm TC, i.d. 10 mm 18101264 408.00 USD Add to cart
Get Quote
2 Tubing, 300 mm, 25 mm TC, i.d. 10 mm 18101285 344.00 USD Add to cart
Get Quote
2 Tubing, 400 mm, 25 mm TC i.d. 10 mm 18101286 352.00 USD Add to cart
Get Quote
2 Tubing, 2000 mm, 25 mm TC, i.d. 10 mm 18101287 469.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 50 cm, i.d. 6 mm, 25 mm TC 28405368 468.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 80 cm, i.d. 6 mm, 25 mm TC 28405369 491.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 1 m, i.d. 6 mm, 25 mm TC 28405370 495.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 2 m, i.d. 6 mm, 25 mm TC 28405371 630.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 4 m, i.d. 6 mm, 25 mm TC 28405372 765.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 50 cm, i.d. 9.5 mm, 25 mm TC 28405373 476.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 80 cm, i.d. 9.5 mm, 25 mm TC 28405375 530.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 1 m, i.d. 9.5 mm, 25 mm TC 28405376 534.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 2 m, i.d. 9.5 mm, 25 mm TC 28405377 716.00 USD Add to cart
Get Quote
2 Tubing with Sanitary Fittings, 4 m, i.d. 9.5 mm, 25 mm TC 28405378 942.00 USD Add to cart
Get Quote
3 TC-Gasket 25 mm i.d. 15 mm 44549288 169.54 USD Add to cart
Get Quote
4 TC clamp kit, 25 mm TC 28404336 245.00 USD Add to cart
Get Quote
4 TC Clamp kit TC25/SS 28404338 120.33 USD Add to cart
Get Quote
5 Valve 4-port, 2-way ID 10 18101256 1 726.00 USD Add to cart
Get Quote
5 Valve 4-Port 2-Way ID 6 mm 18575701 1 694.00 USD Add to cart
Get Quote
6 Gasket 25 mm, i.d. 6 mm 18001927 15.42 USD Add to cart
Get Quote
6 TC-Gasket 25 mm i.d. 10 mm 18103579 31.97 USD Add to cart
Get Quote
6 TC-gasket 25/8 EPDM 28950948 61.81 USD Add to cart
Get Quote
Blind Flange, including gasket, 25 mm 18100125 76.96 USD Add to cart
Get Quote

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 FEP Tubing, i.d. 1/8 in (3/16 in) 18111247 88.60 USD Add to cart
Get Quote
4 Connector, 25 mm TC i.d. 6 mm - M6 Female 18103109 117.44 USD Add to cart
Get Quote
4 Connector M6 Female - 25 mm TC, 6 mm, i.d. 1.9 mm 28405764 1 065.00 USD Add to cart
Get Quote
5 Fingertight Union 1/16" Male/M6 Female 18111258 111.71 USD Add to cart
Get Quote
6 Gasket 25 mm, i.d. 6 mm 18001927 15.42 USD Add to cart
Get Quote
7 Gaskets, 25 mm, i.d. 6 mm 18001928 35.61 USD Add to cart
Get Quote
8 TC-gasket 25/8 EPDM 28950948 61.81 USD Add to cart
Get Quote
9 TC Clamp kit TC25/SS 28404338 120.33 USD Add to cart
Get Quote

Spare parts

Fig 2. BPG 140, column parts identification.

Item numbers are not necessarily in sequential order. For parts shown in the figure but not listed below, please contact your sales or service representative.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
14 Washer 8.4x16x1.6 A4 18111329 54.14 USD Add to cart
Get Quote
16 TC Clamp 25mm SS 18100131 38.30 USD Add to cart
Get Quote
17 Adjusting Knob BPG 100-140-200 18110927 1 049.00 USD Add to cart
Get Quote
18 Domed nut M8 BPG 140 and 200 18111327 53.77 USD Add to cart
Get Quote
20 Bushing Ring BPG 140/200 18026701 102.18 USD Add to cart
Get Quote
21 Top plate BPG 140 18111324 670.00 USD Add to cart
Get Quote
22 Adjuster Nut BPG 140 and 200 18025220 994.00 USD Add to cart
Get Quote
23 Allen screw, M8 x 45 19637501 58.54 USD Add to cart
Get Quote
24 Allen screw, M4 x 14 19635601 76.85 USD Add to cart
Get Quote
25 Stopper BPG 140, 200 18111325 187.08 USD Add to cart
Get Quote
26 Adaptor head screw 18845701 145.58 USD Add to cart
Get Quote
27 Sealing unit BPG 140 18111331 906.00 USD Add to cart
Get Quote
28 O-Ring 120X5 EPDM 140 Columns 18111310 38.20 USD Add to cart
Get Quote
28 O-Ring 120x5 FEP BPG 140 18111311 335.00 USD Add to cart
Get Quote
30 Inner Adaptor Tube BPG 100-140-200 18111323 247.00 USD Add to cart
Get Quote
31 Outer Adaptor Tube BPG 100, 140, 200 18113483 1 693.00 USD Add to cart
Get Quote
32 Screw M6X12 BPG 100, 140 and 200 18114508 92.81 USD Add to cart
Get Quote
34 Adaptor plate BPG 140 18111330 912.00 USD Add to cart
Get Quote
35 Support net, adaptor 140 column 18111299 46.70 USD Add to cart
Get Quote
36 Net, 23 μm adaptor 140 column PP 18111301 267.00 USD Add to cart
Get Quote
36 Net, 10 μm adaptor 140 column PA 18111303 180.21 USD Add to cart
Get Quote
36 Net, 54 μm adaptor BPG 140 PP 18112698 933.00 USD Add to cart
Get Quote
36 Net, 12 μm adaptor BPG 140 PEEK 18114839 471.00 USD Add to cart
Get Quote
37 TC-gasket 25/8 EPDM 28950948 61.81 USD Add to cart
Get Quote
43 Support Washer BPG Columns 18114280 88.32 USD Add to cart
Get Quote

O-rings and nets should be checked regularly for wear. Worn O-rings may not seal properly and over-used nets can affect distribution. Inspect the O-rings and evaluate the height equivalent to a theoretical plate (HETP) and peak asymmetry factor (As) to prevent poor performance due to old nets.

We recommend you to change the nets and O-rings when needed or at least annually. Please keep a set of each on your site, for code numbers refer to the table below. 

The column is delivered with O-rings in Ethylene propylene diene (EPDM). Ethylene propylene diene change characteristics when exposed to some organic chemicals. For repetitive long term use, use Fluoroethenepropene (FEP) polymers.

23 µm nets are supplied with the column and recommended for beads with an average particle diameter between 70-150 µm. For an average particle diameter < 70 µm use 10 µm or 12 µm nets and for an average particle diameter > 150 µm use 54 µm nets.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 O-Ring 142,5X3,5 EPDM BPG/INdEX 140 18111306 32.77 USD Add to cart
Get Quote
2 O-Ring 142.5x3.5 FEP BPG 140 18111307 435.00 USD Add to cart
Get Quote
3 O-Ring 120X5 EPDM 140 Columns 18111310 38.20 USD Add to cart
Get Quote
4 O-Ring 120x5 FEP BPG 140 18111311 335.00 USD Add to cart
Get Quote
5 Support net, adaptor 140 column 18111299 46.70 USD Add to cart
Get Quote
6 Support net, end-piece 140 column 18111298 46.70 USD Add to cart
Get Quote
7 Net, 10 μm adaptor 140 column PA 18111303 180.21 USD Add to cart
Get Quote
8 Net, 10 μm, end-piece 100 column PA 18025177 286.00 USD Add to cart
Get Quote
9 Net, 12 μm adaptor BPG 140 PEEK 18114839 471.00 USD Add to cart
Get Quote
10 Net, 12 μm, end-piece BPG140 PEEK 18114840 403.00 USD Add to cart
Get Quote
11 Net, 23 μm adaptor 140 column PP 18111301 267.00 USD Add to cart
Get Quote
12 Net, 23 μm, end-piece 140 column PP 18111300 269.00 USD Add to cart
Get Quote
13 Net, 54 μm adaptor BPG 140 PP 18112698 933.00 USD Add to cart
Get Quote
14 Net, 54 μm, end-piece BPG 140 PP 18112699 824.00 USD Add to cart
Get Quote
15 Guide ring BPG 140 18111297 199.07 USD Add to cart
Get Quote

Figure 1. BPG 140, column parts identification.

Item numbers are not necessarily in sequential order. For parts shown in the figure but not listed below, please contact your sales or service representative.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
2 Tie Rod BPG 140 - 200/500 29270157 128.46 USD Add to cart
Get Quote
3 Guide ring BPG 140 18111297 199.07 USD Add to cart
Get Quote
4 Net, 23 μm, end-piece 140 column PP 18111300 269.00 USD Add to cart
Get Quote
4 Net, 10 μm, end-piece 140 column PA 18111302 306.00 USD Add to cart
Get Quote
4 Net, 54 μm, end-piece BPG 140 PP 18112699 824.00 USD Add to cart
Get Quote
4 Net, 12 μm, end-piece BPG140 PEEK 18114840 403.00 USD Add to cart
Get Quote
5 Support net, end-piece 140 column 18111298 46.70 USD Add to cart
Get Quote
6 O-Ring 142,5X3,5 EPDM BPG/INdEX 140 18111306 32.77 USD Add to cart
Get Quote
6 O-Ring 142.5x3.5 FEP BPG 140 18111307 435.00 USD Add to cart
Get Quote
8 Nut, M8 19076301 196.67 USD Add to cart
Get Quote
9 Washer 8.4x16x1.6 A4 18111329 54.14 USD Add to cart
Get Quote
12 End piece BPG 140 18111320 1 181.00 USD Add to cart
Get Quote
13 Bolt M8X12 BPG 140 and 200 18111328 28.38 USD Add to cart
Get Quote
14 Washer 8.4x16x1.6 A4 18111329 54.14 USD Add to cart
Get Quote
15 Column Stand 140/200 Columns 18103120 2 353.00 USD Add to cart
Get Quote
16 TC Clamp 25mm SS 18100131 38.30 USD Add to cart
Get Quote
37 TC-gasket 25/8 EPDM 28950948 61.81 USD Add to cart
Get Quote
38 Adjustable Foot 18112693 43.51 USD Add to cart
Get Quote
40 Valve 4-Port 2-Way ID 6 mm 18575701 1 694.00 USD Add to cart
Get Quote

Troubleshooting

Find solutions to product related issues. For unlisted issues please contact local Cytiva service representation.

General advice to achieve good performance

Before packing or running the column please make sure that

  • the tubing, valves, gaskets etc. have the same inner diameter as the column in and outlets and tubing is not longer than needed.
  • the bed supports have a porosity appropriate for your chromatography medium.
  • the column has been correctly assembled, verified by passing a leakage test.
  • the chromatography medium and equipment are equilibrated in the packing buffer and to ambient temperature of packing environment.
  • that the pump is free from pulsations.
  • no pressure peaks appear.
  • that you have enough slurry volume, taken in account the compression factor of the medium.
  • packing is performed at optimal flow velocity.
  • the column meets pressure requirement for selected medium and packing procedure.

After completing the packing procedure please evaluate the efficiency of the column in terms of the height equivalent to a theoretical plate (HETP), reduced plate number (h) and the peak asymmetry factor (As).


Between batches it is recommended to perform cleaning-in-place (CIP) to remove precipitated material, strongly bound substances and other contaminants from the column bed without dismantling the column. Regular CIP is needed to ensure proper product quality and expected life time of medium and equipment.

Many issues that face chromatographers are common to all types of columns, while other issues are quite specific.
Select the appropriate equipment.

Worrying peak shape

Strange peaks

Column leakage

Poor reproducibility

Back pressure increases during operation

Unusual column appearance

Poor product recovery

Drifting baseline

Poor packing evaluation result

On this troubleshooting site, we refer to leading and tailing peaks as defined according to the following figures.


Leading peak

Tailing peak

 
Experience shows that the best method of expressing the efficiency of a packed column is in terms of its height equivalent to a theoretical plate (HETP), reduced plate number (h) and its peak asymmetry factor (As).

Unsatisfactory elution

Contact